Model 5010 Time Code Master Manual
SERIAL REMOTE CONTROL PROTOCOL
Revision 3.1.1
Page 5-15
A4 Sense Generator Parity
Returns 1 byte as defined below.
84
Select Generator Parity
1 byte
Selects whether the Generator will operate
with PARITY On or Off.
00 = Parity Off
01 = Parity On
A5 Sense VITC Generator On/Off
Returns 1 byte as defined below.
85
Select VITC Generator On/Off
1 byte
Turns the VITC Generator On and Off.
00 = VITC Generator Off
01 = VITC Generator On
A6 Sense Generator Run/Hold
Returns 1 byte as defined below.
86
Select Generator Run/Hold
1 byte
Turns Generator Hold On and Off.
00 = Generator Hold
01 = Generator Run
A7 Sense Generator Jam Sync Mode
Returns 1 byte as defined below.
87
Select Generator Jam Sync Mode
1 byte
Turns Generator Jam Sync mode.
00 = Generator Free Run (Jam Off)
01 = Continuous Jam Sync
02 = Momentary Jam Sync
"
When Continuous Jam Sync mode is enabled, then generator time will be slaved to
the time code from the Reader. The Run/Hold, Drop Frame and Colour Frame modes
of the generator are determined by the Reader time code. When Continuous Jam
Sync mode is terminated, the formatted Run/Hold, Drop Frame and Colour Frame
modes of the generator are resumed.
A8 Sense Generator No Code Jam
Returns 1 byte as defined below.
88
Select Generator No Code Jam
1 byte
Determines the behavior of the Generator
when it is in continuous jam sync mode and
there is no incoming code to the reader.
00 = Hold
01 = Run
02 = Mute
89
Preset Generator Time
4 bytes
Presets the time code generator. This
command has no effect when the generator
is in continuous Jam Sync mode. Expects
four bytes of time data in BCD format as
shown below.
10 Fr
1 Fr
10 Sec
1 sec
10 Min
1 Min
10 Hr
1Hr
Содержание 5010
Страница 2: ...This page left intentionally blank ...
Страница 6: ...Model 5010 Time Code Master Manual Revision 3 1 1 REVISION HISTORY This page left intentionally blank ...
Страница 12: ...Model 5010 Time Code Master Manual Page vi Revision 3 1 1 TABLE OF CONTENTS This page left intentionally blank ...
Страница 14: ...Model 5010 Time Code Master Manual Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 20: ...Model 5010 Time Code Master Manual Page 1 6 Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 22: ...Model 5010 Time Code Master Manual Revision 3 1 1 INSTALLATION This page left intentionally blank ...
Страница 30: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL SPECIFICATIONS This page left intentionally blank ...
Страница 96: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...
Страница 106: ...Model 5010 Time Code Master Manual Page 6 10 Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...