Model 5010 Time Code Master Manual
OPERATING INSTRUCTIONS
Revision 3.1.1
Page 4-5
4.3.1. Selecting and Positioning the Individual Character Inserter Windows
Press
VCG MODE
to enable the window select mode. All four windows will appear on the character
screen with the window for the generator Time highlighted. Use the arrow keys (
Ï
,
Ð
,
Í
,
Î
) to
position the generator Time window on the screen. Press the
VCG ON/OFF
key to turn the window on
or off. Press the
VCG MODE
key to highlight the generator User Bits window. Use the
VCG ON/OFF
key to turn it on or off and the arrow keys to move it to the desired location. Press the
VCG MODE
key
to select the next window, etc.
Example:
To move only the generator Time window down one line, leaving the generator user bit
window in the same place, press
VCG MODE
three times and press the
Ð
key. Press the
CLEAR
key to return to the normal display mode.
4.3.2. Positioning the Overall Character Display
In the normal VCG display mode, when neither of the windows is highlighted, the arrow keys (
Ï
,
Ð
,
Í
,
Î
) move all the displayed windows by the same relative amount.
Example:
To move the time and user bits windows down by one line press the
Ð
key.
4.3.3. Special VCG Indicators
The following special indicators are used between the seconds and frames digits of the time windows in
the character inserter to identify non drop frame and drop frame code (NTSC only).
Non Drop Frame
Colon (:)
Drop Frame (NTSC)
Period (.)
When the Generator Assignment is set to TIME DATE mode, the following special indicators are used
between the hours and minutes digits of the time windows in the character inserter to identify daylight
saving or standard time.
Standard Time
Colon (:)
Daylight Saving Time
Period (.)
4.3.4. Field
Identification
When displaying time from the VITC generator or reader, (model 5010-VITC only) the field number
sequence will be displayed to the right of the time frames display. When the data is in the non colour
frame mode the field number sequence will be 1, 2, 1, etc. (1, 2, 3, 4, 1, etc. for PAL). When the reader
data was recorded in the colour frame mode, the field number sequence will be 1, 2, 3, 4, 1, etc. (1, 2,
3, 4, 5, 6, 7, 8, 1, etc. for PAL). The field number display may be disabled using the VCG FIELDS item
in the VCG menu.
4.4.
ON SCREEN PROGRAMMING MENU – OVERVIEW
The key to the operational flexibility of the model 5010 lies in the powerful on screen programming
menu system that uses the built in character generator. This method of configuring the model 5010 is
quick, and simple, guiding you to the correct setup for your application. Six front panel push buttons (
Í
,
Î
,
Ï
,
Ð
, and
SELECT
and
SETUP
) are used to cycle through the various items on the
programming menu.
Содержание 5010
Страница 2: ...This page left intentionally blank ...
Страница 6: ...Model 5010 Time Code Master Manual Revision 3 1 1 REVISION HISTORY This page left intentionally blank ...
Страница 12: ...Model 5010 Time Code Master Manual Page vi Revision 3 1 1 TABLE OF CONTENTS This page left intentionally blank ...
Страница 14: ...Model 5010 Time Code Master Manual Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 20: ...Model 5010 Time Code Master Manual Page 1 6 Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 22: ...Model 5010 Time Code Master Manual Revision 3 1 1 INSTALLATION This page left intentionally blank ...
Страница 30: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL SPECIFICATIONS This page left intentionally blank ...
Страница 96: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...
Страница 106: ...Model 5010 Time Code Master Manual Page 6 10 Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...