Model 5010 Time Code Master Manual
Page 6-8
Revision
3.1.1
TECHNICAL DESCRIPTION
6.4.3. Upgrading the Firmware
1.
Connect the 5010 to the computer’s serial port using the cable described in section 6.4.1 or
6.4.2. Most computers have two serial communications ports (known as COM1 and COM2).
If you have both serial ports available, connect the 5010 to COM1.
2.
If you received the firmware update on floppy disk, insert the reprogramming diskette in the
drive of the computer. Change directories to the root of the reprogramming diskette’s drive
(A: or B:)
"
Copy files to Hard Disk before upgrade.
If you downloaded the firmware from our Firmware FTP site, change to the directory of your
hard disk where you have the upgrade files located. The upgrade files you downloaded
have been compressed in Zip format and will need to be extracted before you can proceed.
Expand the upgrade files into this directory by running the WinZip utility (available from our
FTP site)
3.
To set up the 5010 for programming at 38400 baud, hold down the
Ï
key while you apply
power to the 5010. When the 5010 completes its boot-up sequence, the front panel will
display
LOAD FLASH - 38400.
The default baud rate for reprogramming is 38400.
To set up the 5010 for programming at 9600 baud hold down the
Ð
key while you apply
power to the 5010. When the 5010 completes its boot-up sequence, the front panel will
display
LOAD FLASH - 9600
4.
The 5010 firmware is contained in an Intel HEX format file. The chart below shows the
correct HEX file to load for the 5010 version you have:
Firmware
Model
Old Style
New Style
5010
AG52A1.HEX AG57A1.HEX
5010-VITC
AG52A1.HEX AG57A1.HEX
5010-24
AG52A6.HEX AG57A6.HEX
5010-VITC-24
AG52A6.HEX AG57A6.HEX
5.
A Flash Loader software utility (called FL.EXE) was provided along with the upgrade files
you received. This utility uploads the HEX file to the 5010. Run FL.EXE, with the
appropriate '.hex' file as the first argument. For example:
FL AG57A1.HEX
This will run the Flash loader program in its default configuration: COM1, 38400 baud,
software flow control.
Содержание 5010
Страница 2: ...This page left intentionally blank ...
Страница 6: ...Model 5010 Time Code Master Manual Revision 3 1 1 REVISION HISTORY This page left intentionally blank ...
Страница 12: ...Model 5010 Time Code Master Manual Page vi Revision 3 1 1 TABLE OF CONTENTS This page left intentionally blank ...
Страница 14: ...Model 5010 Time Code Master Manual Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 20: ...Model 5010 Time Code Master Manual Page 1 6 Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 22: ...Model 5010 Time Code Master Manual Revision 3 1 1 INSTALLATION This page left intentionally blank ...
Страница 30: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL SPECIFICATIONS This page left intentionally blank ...
Страница 96: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...
Страница 106: ...Model 5010 Time Code Master Manual Page 6 10 Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...