8
Performance* SectIon
ro Production
†
enVI-ro 600
Gallons per Day
600
Gallons per Hour
25
Ounces per Minute
53
Inlet Supply
Requirements,
Minimum
1.5 gpm
Reject to Drain,
Maximum
0.85 gpm
†Production rates based on the following:
750 ppm TDS Soft Water @ 50 psi, 77°F, to Atmosphere, Recovery = 40%, SDI = <3,
Stored Water System
Flowrate (gpm)
Dependant on: Pressure/volume in storage, line sizes
Volume (Gallons)
Dependant on: Pressure/volume in storage
Pressure (typical)
60–100 psi (4.1-6.9 bar)
Salt Rejection
90% minimum
Recovery
Varies based on water conditions - 30-80%
dImenSIonS and oPeratIng WeIgHtS
System only
enVI-ro (eV9970-38)
Dimensions
32"H x 23"W x 13.6"D
Operating Weight
90 lbs.
cartridges and elements
Reverse Osmosis
24-inch TFC
Conditioning Cartridge
10-inch Scale Control
Carbon Post-Filter
10-inch In-line
*Specifications Subject To Change Without Notice.
Содержание ENVI-RO
Страница 13: ...13 13 6 346 23 583 406 16 32 Side View Front View Top View 813 Figure 7 Dimensional Drawing...
Страница 14: ...14 Figure 8 General Installation Arrangement...
Страница 15: ...15 NOTES...