maIntenance

The ENVI-RO requires very little maintenance. Regular cartridge 

replacement is the only normal requirement, and a very important 

one. In typical service, the cartridge change-out schedules are as 

listed below. 

every 6 months
 - replace the Sr cartridge:

Open both by-pass valves.

• 

Remove power from system by unplugging power cord.

• 

Close the inlet valve.

• 

Follow instructions on the SR cartridge label. Place a bucket 

• 

under the cartridge to catch any excess water that may spill from 

the head. Remove the old cartridge by turning the cartridge to 

the left until it stops and pulling it downward until it is free from 

its head.
Remove the outer shrink-wrap and protective cap from the new 

• 

SR cartridge.
Align the lugs on the new cartridge with the slots in the head.

• 

Holding the head and cartridge firmly, press the cartridge 

• 

upward into the head fully, and then turn the cartridge to the 

right until it stops.
Disconnect 3/8” OD line from SR Cartridge to Booster Pump 

• 

inlet at Booster Pump. Route line into bucket and secure. Plug-in 

power cord. 
Route a blue line from the 3/8” storage tank drain valve to drain 

• 

temporarily. Open inlet valve. Open storage tank drain valve. 

Drain storage tank until system starts processing water. Close 

storage tank drain valve.
Once a solid flow of water has been established, flush 1 gallon. 

• 

Unplug power cord. Re-connect 3/8” OD line to Booster Pump 

inlet. Plug in power cord.
Close both by-pass valves.

• 

every 12 months
– Sanitize the storage tank and lines:

Refer to “Disinfection” section - steps 1-8, for sanitization 

• 

procedure.

– replace the ro cartridge:

Open both by-pass valves.

• 

Remove power from system by unplugging power cord.

• 

Close the inlet valve.

• 

Follow instructions on the MR cartridge label. Place a bucket 

• 

under the cartridge to catch any excess water that may spill from 

the head. Remove the old cartridge by turning the cartridge to 

the left until it stops and pulling it downward until it is free from 

its head.
Remove the outer shrink-wrap and protective cap from the new 

• 

MR cartridge.
Align the lugs on the new cartridge with the slots in the head.

• 

Holding the head and cartridge firmly, press the cartridge 

• 

upward into the head fully, and then turn the cartridge to the 

right until it stops.
Remove both capillary restrictors temporarily.

• 

Route a blue line from the 3/8” storage tank drain valve to drain 

• 

temporarily. Open inlet valve. Open storage tank drain valve. 

Plug-in power cord. 

Drain storage tank until system starts processing water. Once 

• 

a solid flow of water has been established, flush 5 gallons from 

tank drain (about 10 minutes). Unplug power cord.

WARNING

  do not uSe tHIS Product Water! It may contain 

a preservative solution from the ro cartridge and 

should not be consumed!

Re-install capillary tubes.

• 

Close both by-pass valves.

• 

– replace the Post carbon cartridge:

Open both by-pass valves.

• 

Remove power from system by unplugging power cord.

• 

Close the inlet and both outlet valves.

• 

Route a blue line from the 3/8” storage tank drain valve to drain 

• 

temporarily. Open storage tank drain valve. Drain storage tank. 

Close storage tank drain valve.
Follow instructions on the Post Carbon cartridge label. Place a 

• 

bucket under the cartridge to catch any excess water that may 

spill when removing lines. Remove lines, note flow direction, then 

remove cartridge.
Install new cartridge, in same flow direction as original cartridge. 

• 

Connect lines.
Plug-in power cord. Once a solid flow of water has been 

• 

established, flush 5 gallons from tank drain.
Close storage tank drain valve.

• 

Open the inlet and both outlet valves.

• 

Close both by-pass valves.

• 

Содержание ENVI-RO

Страница 1: ...increases the inlet pressure to maintain consistent permeate production plus eliminates back pressure on the permeate output This innovative approach to both boosting and eliminating back pressure al...

Страница 2: ...ler Power Supply Storage Tank Wall Mount Bracket 2 MR 600 RO cartridge 3 2SR BW Cartridge 4 Parts Kit 5 Inspect the carton for damage Report any damage to freight carrier immediately and retain all pa...

Страница 3: ...ectionable taste Plastic pipe or reinforced tubing are generally very good choices for RO water distribution materials The size of the product water tubing piping should be 3 8 ID minimum Distances of...

Страница 4: ...alue in seconds is entered for this setting Range is 0 995 seconds in 5 second increments Use the keys to adjust this value Press Enter to save value and go to next screen Flush Int X2 This parameter...

Страница 5: ...o your TDS measurement Read across that row to determine maximum recovery permeate to reject ratio and permeate reject volumes Using 2 32 oz or 1 000 ml graduated containers apply power 2 to the syste...

Страница 6: ...1 321 67 9 679 751 1000 30 0 1 to 2 33 30 0 300 70 0 700 Table 2 Capillary Tube and Flush Time Selector Reject Volume per Minute Capillary Tube Flush Time in Seconds Ounces Milliliters 1 2 0 0 6 1 0 1...

Страница 7: ...odor is detected from 8 the water exiting the storage tank or connected equipment Placing ENVI RO Into Service Once the cartridges have been activated the storage tank and distribution piping sanitiz...

Страница 8: ...pm Dependant on Pressure volume in storage line sizes Volume Gallons Dependant on Pressure volume in storage Pressure typical 60 100 psi 4 1 6 9 bar Salt Rejection 90 minimum Recovery Varies based on...

Страница 9: ...9 maintenance section Performance Log Test Date Outlet Flow ml min Drain Flow ml min Inlet Pressure Temp psi F Inlet TDS ppm STEAMER Outlet TDS ppm COFFEE Outlet TDS ppm Reduction NOTES...

Страница 10: ...capacity if applicable c Low quality RO water 3 Refer to problem 1 a Refer to problem 1 a RO cartridge failure b Replace RO cartridge b Low water pressure at water 4 using equipment Tubing piping run...

Страница 11: ...13 EV312827 RESTRICTOR BLUE 735 ml min 13 EV312828 RESTRICTOR WHITE 1052 ml min 13 EV312829 RESTRICTOR GREY 1577 ml min 13 EV312830 RESTRICTOR RED 125 ml min 13 EV312831 RESTRICTOR BROWN 189 ml min 1...

Страница 12: ...instructions on the MR cartridge label Place a bucket under the cartridge to catch any excess water that may spill from the head Remove the old cartridge by turning the cartridge to the left until it...

Страница 13: ...13 13 6 346 23 583 406 16 32 Side View Front View Top View 813 Figure 7 Dimensional Drawing...

Страница 14: ...14 Figure 8 General Installation Arrangement...

Страница 15: ...15 NOTES...

Страница 16: ...00 942 1153 www everpure com Printed in U S A EV3128 25 Rev A SE08 For sales replacement components and service contact your Everpure dealer or Everpure LLC 1040 Muirfield Drive Hanover Park Illinois...

Отзывы: