IntroductIon

The Everpure ENVI-RO™ Mineral Reduction System is a pre-

engineered, pre-assembled Reverse Osmosis (RO) system designed 

to provide high purity water for multiple applications, such as 

premium espresso, coffee, blended beverages and steam, to name a 

few. It combines a number of water treatment technologies into one 

easy to install package. The system provides superior protection 

against taste and odor causing contaminants while removing dirt, 

particulates and dissolved solids that can foul or scale equipment.

Initial System Production

Water production depends on supply water pressure and temperature. 

See PERFORMANCE section (page 8) for normalized production.

Influent Water characteristics

The following table lists the allowable operating range of various 

water properties within which the ENVI-RO™ will function  

properly.

 

Total Dissolved Solids (TDS)

0-1,000 ppm (0-1,000 mg/I)

pH

5-10

Chlorine

1

0-3 ppm (0-3 mg/I)

Chloramines

0-3 ppm (0-3 mg/I)

Turbidity

0-1 NTU

Iron

0-1 ppm (0-1 mg/I)

1

 Reverse osmosis membrane filter used in this system will be damaged by chlorine. An 

activated carbon filter should be provided with this system to protect the reverse osmosis 
membrane from chlorine attack. Influent chlorine should not exceed 3 mg/I.

the system consists of 5 major components:

2SR-BW Water Conditioning cartridge

1. 

Dual-Head booster pump

2. 

MR-600 Reverse Osmosis (RO) membrane cartridge.

3. 

6-Gallon RO Water Storage Tank

4. 

Control System with Power Supply

5. 
The 2SR-BW Water Conditioning cartridge contains media that 

reduces the scaling tendency of hard water minerals found in many 

water supplies, extending RO membrane life. 
The Dual-Head booster pump increases the inlet pressure to 

maintain consistent permeate production, plus eliminates back-

pressure on the permeate output. This innovative approach to both 

boosting and eliminating back-pressure allows for maximum system 

efficiency. 
The MR-600 RO membrane cartridge contains a semi-permeable 

reverse osmosis membrane. Here, most dissolved impurities are 

separated from the water and flushed down the drain. The water 

that is able to pass through the membrane, which is very low in 

dissolved impurities, is referred to as permeate, RO water, or 

product water. 
Once the RO water is produced, it is stored in the 6-Gallon RO Water 

Storage Tank. This tank serves two key functions; 1) It acts as a 

buffer between the system and the connected equipment, providing 

ample volumes of water instantaneously, 2) It reduces the on-off 

cycling of the RO system, which  produces better quality water, and 

prolongs the system’s life. 

oPeratIng SPecIfIcatIonS

Dynamic Operating Pressure: 25-80 psi (1.7-5.5 bar)

• 

Static Operating Pressure: 100 psi (6.9 bar)

• 

Operating Temperature 40-100°F (4.4-37.8°C)

• 

Connections

• 

Inlet/Outlet: 3/8-inch OD tube (John Guest© Push-in)  

Concentrate: 3/8-inch OD tube (John Guest© Push-in)  

Electrical: 115 volt AC / 60 Hz / 1 Phase

Ampere: 

  Stand-by:   0.2

  Flush: 

0.5

  Run/Fill: 

2.7

Branch Circuit Protection: 15 or 20 AMP Ground Fault Protected

Pre-Installation checklist

Can

1. 

 the unit be mounted within a reasonable distance of the 

water supply and drain facilities?
Is 

2. 

there an un-switched 115 VAC GFIC (ground fault interrupter 

circuit) protected receptacle available for powering the system?
Is 

3. 

there adequate clearance and support to install the unit 

and permit access for maintenance? The total system weight 

will vary based on model and storage tank selected. See 

specification table for approximate operating weights.
Doe

4. 

s the inlet water supply meet the requirements listed below? 

A minimum of 25 PSI pressure on a consistent basis

a. 

Less than 1,000 ppm of Total Dissolved Solids (TDS)

b. 

pH level between 7.0-9.0

c. 

Turbidity less than 1 NTU

d. 

Содержание ENVI-RO

Страница 1: ...increases the inlet pressure to maintain consistent permeate production plus eliminates back pressure on the permeate output This innovative approach to both boosting and eliminating back pressure al...

Страница 2: ...ler Power Supply Storage Tank Wall Mount Bracket 2 MR 600 RO cartridge 3 2SR BW Cartridge 4 Parts Kit 5 Inspect the carton for damage Report any damage to freight carrier immediately and retain all pa...

Страница 3: ...ectionable taste Plastic pipe or reinforced tubing are generally very good choices for RO water distribution materials The size of the product water tubing piping should be 3 8 ID minimum Distances of...

Страница 4: ...alue in seconds is entered for this setting Range is 0 995 seconds in 5 second increments Use the keys to adjust this value Press Enter to save value and go to next screen Flush Int X2 This parameter...

Страница 5: ...o your TDS measurement Read across that row to determine maximum recovery permeate to reject ratio and permeate reject volumes Using 2 32 oz or 1 000 ml graduated containers apply power 2 to the syste...

Страница 6: ...1 321 67 9 679 751 1000 30 0 1 to 2 33 30 0 300 70 0 700 Table 2 Capillary Tube and Flush Time Selector Reject Volume per Minute Capillary Tube Flush Time in Seconds Ounces Milliliters 1 2 0 0 6 1 0 1...

Страница 7: ...odor is detected from 8 the water exiting the storage tank or connected equipment Placing ENVI RO Into Service Once the cartridges have been activated the storage tank and distribution piping sanitiz...

Страница 8: ...pm Dependant on Pressure volume in storage line sizes Volume Gallons Dependant on Pressure volume in storage Pressure typical 60 100 psi 4 1 6 9 bar Salt Rejection 90 minimum Recovery Varies based on...

Страница 9: ...9 maintenance section Performance Log Test Date Outlet Flow ml min Drain Flow ml min Inlet Pressure Temp psi F Inlet TDS ppm STEAMER Outlet TDS ppm COFFEE Outlet TDS ppm Reduction NOTES...

Страница 10: ...capacity if applicable c Low quality RO water 3 Refer to problem 1 a Refer to problem 1 a RO cartridge failure b Replace RO cartridge b Low water pressure at water 4 using equipment Tubing piping run...

Страница 11: ...13 EV312827 RESTRICTOR BLUE 735 ml min 13 EV312828 RESTRICTOR WHITE 1052 ml min 13 EV312829 RESTRICTOR GREY 1577 ml min 13 EV312830 RESTRICTOR RED 125 ml min 13 EV312831 RESTRICTOR BROWN 189 ml min 1...

Страница 12: ...instructions on the MR cartridge label Place a bucket under the cartridge to catch any excess water that may spill from the head Remove the old cartridge by turning the cartridge to the left until it...

Страница 13: ...13 13 6 346 23 583 406 16 32 Side View Front View Top View 813 Figure 7 Dimensional Drawing...

Страница 14: ...14 Figure 8 General Installation Arrangement...

Страница 15: ...15 NOTES...

Страница 16: ...00 942 1153 www everpure com Printed in U S A EV3128 25 Rev A SE08 For sales replacement components and service contact your Everpure dealer or Everpure LLC 1040 Muirfield Drive Hanover Park Illinois...

Отзывы: