NO.
Trouble
Solution
Possible Cause
18
Arc will not start unless lift started.
Check HF point gap. Clean and set to
.035”
Contact
Technical Support for details. Make sure unit is set to
HF
Points misadjusted, worn or dirty.
HF not selected
19
Tungsten is rapidly consumed.
Check gas flow. Check for Leaks thoughout system/
regulator/tank. Check for 100% Argon. Use red thori-
ated or any other type besides Green (Pure) or Zirconi-
ated. Put torch in Negative.
Inadequate gas flow. Too small of
tungsten. Wrong shielding gas. Use
only Ar. Using green tungsten.
Wrong polarity. Possible contami-
nation of shielding gas from gas
supplier.
20
Tungsten is contaminated, arc changes to
a green color.
Check and adjust stick out to minimum 1/8 inch. Tung-
sten is melting. Reduce amperage or increase tungsten
size. Reduce stick
-
out to less than
1/4”.
Tungsten is dipping into weld. Too
long of stick
-
out.
21
Porosity of the Weld. Discolored weld
color. Tungsten is discolored.
Increase flow rate on regulator. Check for kinks in tub-
ing. Increase post
-
flow time. Reduce stick
-
out to less
than
1/4”.
Increase cup size, or use gas lens. Clean
metal thoroughly with approved metal cleaner, or use
acetone and a rag to clean metal
Low flow rate of shielding gas. High
flow rate of shielding gas. Tungsten
stick
-
out is too far. Too short of
post flow period. Wrong TIG cup
size. Possible gas leaks internally or
externally due to loose fittings.
Base metal is contaminated with
dirt or grease.
22
Weld quality is poor. Weld is dirty/
oxidized, or porous.
Eliminate drafts. Move welder. Check if there is suffi-
cient shielding gas left in tank. Check gas flow. Adjust
for higher flow of gas. Listen for audible click of gas
solenoid. If no click is heard, then contact Everlast
Support. Clean weld properly. Increase pre flow or post
flow.
Drafty conditions. Unit is located
on the workpiece and is blowing gas
off due to fan activity. Solenoid is
sticking. Too short of pre
-
flow or
post
-
flow
23
Unstable Arc.
Regrind to proper point. Wrong polarity. Place torch in
DC negative (
-
). Connect work clamp directly to item
being welded.
Poorly ground or shaped tungsten.
Bad work clamp connection. Metal
is indirectly connected through
table or other item.
24
AC TIG will not weld properly
Check and change immediately.
Wrong connection of work or torch
Troubleshooting Guide
Section 4