![Everlast POWER MTS 221STi Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/everlast/power-mts-221sti/power-mts-221sti_operators-manual_2444094060.webp)
60
Basic Theory and Function
Section 3
Cleaning/Frosted Area of Aluminum
65% EP
Wide bead/etching/balled/consumed
tungsten
EN 35%
EP 65%
50%
EN 65%
EP 35%
50%
Extreme cleaning setting. 65% EP:
Shallow penetration, balling tungsten, excessive cleaning area.
Good penetration setting 35% EP:
Deeper penetration, sharper tungsten, narrow cleaning area.
EN 50%
EP 50%
50%
Standard transformer welder balance: 50% EN/EP
Balling tungsten, light penetration, wide cleaning area.
1 Hz (one full AC cycle)
EXAMPLE: AC EP (+) BALANCE
NOTE:
1.
Due to the rapid switching of the inverter, High Frequen-
cy (HF) is not needed except to start the arc. The HF TIG only
refers to the initial arc start, and can be used for DC as well.
In a transformer welder, the HF could be switched to contin-
uous to stabilize the AC arc, but in an inverter, this is not
necessary. So, the HF switch refers only to the Start of the
arc, and not to AC operation. However to reduce tungsten
contamination with aluminum, you should only operate the
AC mode with the HF start selected. Lift start is recommend-
ed only for DC, or for AC when a copper scratch block is used
and the arc is transferred. Lift start would be used in areas
that are sensitive to electronic interference such as hospitals
or computer/CNC equipment.
2.
The addition of Helium to Argon can increase the welding
capacity of the welder and alter the amount of cleaning typi-
cally needed. Do not exceed 25% however or arc starts will
be difficult and erratic.
3.
If arc wandering in AC is a problem, reduce cleaning percent,
then if it continues, reduce gas flow and then check for drafts
or for poor work clamp connection. Also check for highly
oxidized or dirty aluminum or a faulty work clamp or connec-
tion.
4.
AC controls only apply to AC operation, and do not affect the
settings on DC.
5.
Too slow of travel speed will increase the etching/cleaning
area.
AC TIG Operation
50% EP
Wider bead/etching/balled tungsten
30% EP
Narrow bead/etching/sharp tungsten