38
3.8.4.3
Alarm Action Setting
The Alarm Setting can set the alarm with physical input, as well as the alarm output time of
illegal events, such as the unknown card, invalid card, expired card, invalid time, invalid door
region, etc.
In the submenu of the “Alarm Setting,” select the “Alarm Action Setting” menu item and
press “#” to enter the submenu to set the alarm output time. The submenu has 12 menu
items. Select the corresponding alarm events and Alarm Action Setting for the
corresponding events.
For example, in case of setting the SYS PIN Fail, in the submenu, press “1” to switch
between “Yes” and “No”. Press “#” to enter the alarm time setting interface. All the outputs
of alarm events are latched modes and their settings are similar to the physical alarm input
time setting.
The setting steps of other alarm events are the same as those of the SYS PIN Fail Setting.
3.9
Address Setting
Each device connected to the same RS485 bus must have a unique address for the purpose
of communications and control. When multiple controllers connect to PC via an RS485 bus,
each controller must be assigned a distinct address.
Press the numerical keys to input the address. The range is between 0000~9999. “#” to
confirm and the setting will take effect. Press “*” to exit and the setting will not take effect.
The default address is 0000.
Address:
0000
Cancel
OK
Card Pin Fail
Forced Open Alarm
Held Open Alarm
Panic Open Alarm
Unknown Card
Expire Card Alarm
Invalid Card Alarm
Invalid Time Alarm
SYS PIN Fail
ARM PIN Fail
Tamper Alarm
Remote Alarm
SYS Password Fail
:
N
C a n c e l
N e x t
Alarm Time
000 Min 10 Sec
C a n c e l
O K