6.4
Screen saver
After a period of inactivity set by parameter E0, whatever screen is active at the time will switch to the screen saver showing the values
detected by the probes in use. This function can be disabled by setting parameter E0=0.
To exit the screen saver, touch the display twice: the first time shows the status screen of the controller (the functions of the keys are
not yet active in this screen), while the second touch reactivates all the controller’s functions.
An alarm in progress also automatically shows the status screen of the controller.
6.5
Settings screen
The settings key
on the Stand-by and On screens gives access to the screen where sub-menus can be selected to configure the
controller or check machine status and alarms; some sub-menus are not available when a cycle is in progress or the proofing cycle is
set. The following screen is displayed and can be seen in full by scrolling down with the arrows on the right side of the display:
Press on a description to access the sub-menu.
6.5.1
Manual defrost (for retarding-proofing only)
When this option is pressed, manual defrost starts up if the conditions are met.
6.5.2
Sanitation
The sanitation cycle can be carried out with a UV lamp or an ionizer/ozone generator depending on parameter SA0. These cycles will
only be activated when the door is closed (the label “do not open the door, sanitation cycle in progress” will appear during the cycle); if
the door is opened while the cycle is in progress, the run time will be suspended. Sanitation can be activated only if the temperature of
the room is higher than the temperature set by parameter SA1. The duration of the cycle is set by parameter SA2; when sanitation is
carried out with an ozone generator, rest time is added at the end of the cycle which is set by parameter SA3.
The fan remains on while these cycles are running (except when the door is opened) but regulation is deactivated until the cycle has
finished. The remaining time is shown as the cycle runs.
6.5.3
Alarms
If this option is pressed, the alarms in progress (with automatic and manual reset) are displayed.
When alarms with automatic reset are resolved, they are deleted from the list, while manual alarms must be reset by the user before
they are removed from the list (if the alarm has been resolved).
6.5.4
Internal values
A screen is displayed with the status or value of the controller’s inputs and outputs.