10. CLEANING AND ROUTINE MAINTENANCE 

 

The stove requires simple and frequent cleaning to guarantee maximum efficiency and correct operation. 

The Buyer must carry out regular cleaning of the stove following the instructions contained in this Instruction Manual, and in particular must carry out daily cleaning 

before each ignition or refilling of pellets, the ash drawer, the fire pit and the combustion chamber. 

Failure to clean and/or routinely maintain the stove can cause: malfunctions, obstruction of the fire pit and pipes, poor or slow combustion, or overheating of the 

stove and fire in the hopper. 

Eva Stampaggi S.r.l. assumes no direct and/or indirect criminal and/or civil liability for the malfunction of the stove and for injury to persons or damage to property 

caused by failure to clean/incorrect cleaning or routine maintenance of the stove. 

 

Carry out daily cleaning with a cold boiler as follows: 

 

Vacuum the base of the fire pit inside the combustion chamber 

 

Carry out weekly cleaning with a cold boiler as follows: 

 

Vacuum the combustion chamber, ensuring that there are no burning embers remaining. If embers 

are still burning, the vacuum cleaner will catch fire; 

 

Remove the ash that collects inside the firebox and on the door. 

 

Clean the glass with a damp cloth or with a ball of damp newspaper dipped in ash. If the operation 

is performed with the stove hot there is a risk of the glass exploding. 

 

Empty the ash drawer, by vacuuming it or throwing the ash out with the rubbish. 

 

Vacuum the ash drawer compartment and the adjacent inspection window. 

 

Carry out monthly cleaning with a cold boiler as follows: 

 

Vacuum the T lid of the fume connection. Open the side inspection window and remove the T lid. 

 

Caution: Only use a dry cloth to clean the stove. Do not use abrasive material or products that could corrode or bleach surfaces. At the end of the season, with the 

last ignition, the pellet remaining in the auger must be consumed completely. The auger must remain empty to avoid clogging due to solidified sawdust residue 

created by moisture. 

 

11. NON-ROUTINE CLEANING AND MAINTENANCE 

 

The purchaser must have the flue pipe and ducting cleaned annually, before winter, by qualified technical personnel with the documentation to be shown in the 

event of activation of the warranty. 

Before performing maintenance it is recommended to turn the stove off using the power button, and remove the plug. 

Cleaning must also be carried out before resuming use of the stove, as during the summer there may have been impediments to the regular flow of exhaust gases 

(e.g. nesting, fouling or obstruction). 

Not carrying out non-routine maintenance may cause: negative pressures with poor draught and slow flame, obstruction of the fire pit and pipes, overheating of the 

stove and fire in the fume ducting. 

Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction and those resulting from people or things caused by the 

failure/incorrect extraordinary maintenance of the stove. 

 

It is not uncommon, at the first cold spell and with wind for fires to ignite in the chimney due to the residue build up; some advice in the unfortunate event of this 

happening is: 

 

Block air access to the flue pipe immediately; 

 

Use large handfuls of sand or salt, not water, to extinguish the fire; 

 

Move objects and furniture away from the hot chimney. 

 

Caution: Only use a dry cloth for cleaning the outside of the stove. At the end of the season, with the last ignition, the pellet remaining in the auger must be 

consumed completely. The auger must remain empty to prevent obstruction due to solidified sawdust residue created by moisture. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

Содержание Cesare

Страница 1: ...INSTRUCTION MANUAL STORAGE STOVES COSTANZA EN...

Страница 2: ...facilitate stove s ignition 6 Should any anomaly concerning the flame be detected or however in any other case NEVER SWITCH OFF the stove by disconnecting it from the mains Use the relevant button Dis...

Страница 3: ...STALLATION WARNINGS p 8 07 INSTALLATION p 10 07 1 PROCEDURE FOR CORRECT PRODUCT INSTALLATION p 10 07 2 ELECTRICAL CONNECTIONS p 12 07 3 EXTERNAL THERMOSTAT p 12 07 4 IGNITION p 12 08 PRODUCT USE p 12...

Страница 4: ...technician Should the power supply cable be damaged it can be replaced only by the manufacturer or by its technical assistance service or by a similarly qualified person Do not place any object on th...

Страница 5: ...he appliance will be automatically switched off It may take two separate ignitions to resume operation at ideal working conditions since the Auger tube is very long CAUTION If the stove is not properl...

Страница 6: ...uisiti minimi del tiraggio del camino Pa 12 11 Flue gas temperature Fume temperature C 156 5 83 6 Flue gas temperature at flue spigot or socket Temperatura uscita fumi C 167 3 76 9 Flue gas mass flow...

Страница 7: ...the flue pipe must be carried out in a workmanlike manner and according to European UNI 10683 and national regulations local regulations and the technical specifications and warnings contained in this...

Страница 8: ...n be no bottlenecks No constrictions Use 10cm thick insulating thimbles if pipe vent passes through floors The flue pipe must be insulated along its entire length The insulation will make it possible...

Страница 9: ...f a flue pipe rain fog snow altitude but the most important is the wind which can cause negative thermal pressure as well as dynamic negative pressure The wind action varies depending on whether it is...

Страница 10: ...ENCY OF THE STOVE ENSURE THE FOLLOWING TYPES OF INSTALLATION BEFORE CONNECTION TO THE FLUE PIPE INSTALL THE PRODUCT WITH AT LEAST ONE T AND 1 METERS OF PIPE CERTIFIED ACCORDING TO EN 1856 2 06 INSTALL...

Страница 11: ...d therefore there must not be any open flame apparatus in the same room with the exception of type C boilers airtight Make sure that the stove can draw the necessary quantity of combustion air this mu...

Страница 12: ...hazard such as sheds garages storerooms for combustible materials etc These air intakes must be created in such a way that they cannot be obstructed neither from the inside nor from the outside and m...

Страница 13: ...distribution of the material shake and wiggle the machine during the filling phase to fill every single gap There are 8 sandbags at your disposal Correct filling guarantees the use of all the bags sup...

Страница 14: ...ean Do not use pellets of poor quality The use of substandard pellets can prevent the stove from reaching its maximum yield due to poor combustion and degradation of the stove itself Check that the do...

Страница 15: ...utton to access the menu It includes several items and levels to access settings and control board programming USER MENU The table below briefly describes the menu structure focusing in particular on...

Страница 16: ...n menu STOVE STATUS Enter the STOVE STATUS menu after pressing the P4 button the display scrolls the status of a number of variables during operation of the stove at work menu TECHNICAL This menu item...

Страница 17: ...t value Set temperature value the stove will go back to the Work mode and to the previously set heat output Set heat output If there is an external thermostat and the room temperature has been set to...

Страница 18: ...larm status can be reset by pressing the P3 button Safety thermostat In the event that the general safety thermostat detects a water temperature above the threshold the same intervenes to disconnect t...

Страница 19: ...09 CONNECTIONS 17...

Страница 20: ...use a dry cloth to clean the stove Do not use abrasive material or products that could corrode or bleach surfaces At the end of the season with the last ignition the pellet remaining in the auger must...

Страница 21: ...E RESTARTS IN WORKING MODE FIRE PIT CLEANING WARNING APPEARS AFTER 8 HOURS OF STOVE OPERATION 4 5 KW MODELS ONLY 8 HOURS ARE CUMULATIVE TO CLEAR THE WARNING PRESS ALL 3 BUTTONS ON THE DISPLAY FOR 4 5...

Страница 22: ...THE FIRE DOOR IS CLOSED CORRECTLY CALL TECHNICAL SUPPORT THERM DOOR SAFETY ALARM THERMAL SAFETY THERMOSTAT OR FIRE DOOR OPEN CLOSED INCORRECTLY LET THE STOVE COOL RE ARM THE MANUAL THERMOSTAT AT THE R...

Страница 23: ...tenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ____________ Tech...

Страница 24: ...ion needed to correctly use operate and perform maintenance on the appliance CUSTOMER Signature DEALER INSTALLER Signature Copy of the dealer or installer CERTIFICATE OF INSTALLATION AND TESTING CUSTO...

Страница 25: ...cs of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness any small cracks or cracks that could be highli...

Страница 26: ...sponsibility for such disposal is to be borne by the owner and to not incur sanctions or adverse effects on the environment and health we recommend you contact the local administration the local waste...

Страница 27: ...tion totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vor...

Отзывы: