background image

07. INSTALLATION 

 

HANDLING AND UNPACKING 

When transporting do  not position the product horizontally. Unloading of the product must be performed using lifting means that are suitable and that have 

characteristics that are consistent with the weight of the stove. The operator must make sure that during offloading and lifting of the stove there are no persons or 

objects nearby. When unpacking, avoid damaging the product with cutters or blunt tools. Keep the packaging out of the reach of children. Remove the screws of 

the brackets holding the product to the pallet and put it in position taking care to avoid anything that may block installation or damage the product. Use a lifter or 

pallet truck to separate the apparatus from the transport pallet using the appropriate opening on its base. 

Pay attention to the balance of the product given its size and weight. Turn the fixing brackets to the pallet under the product. They do not need to be removed. 

 

 

PLACE OF INSTALLATION 

Observe the safety distances described above.  

 

CAUTION: THE PRODUCT WEIGHT IS 450 kg. Bear in mind this data should it be necessary to install the stove in attics 

or on second floors. 

 

In compliance with current regulations for installation, the pellet stove must be placed in a ventilated area where sufficient air flows to ensure correct combustion 

and therefore efficient operation. The room must have a volume of no less than 100 m³ and, in order to ensure good combustion.  

(40 m³/h of air) a “combustion air intake” is required, which must reach an external wall or a wall of an adjacent room with external ventilation, provided they are 

equipped with an outside air intake and are not bedrooms or bathrooms or, where there is a fire hazard such as sheds, garages, storerooms for combustible 

materials, etc. These air intakes must be created in such a way that they cannot be obstructed neither from the inside nor from the outside and must be protected 

with grilles, wire mesh or suitable guards, provided that they do not reduce the minimum cross section. 

When in operation, pellet stoves can create negative pressures in the rooms where they are installed. Other naked flame equipment must, therefore, not be present 

in the same room (except only type C (watertight) boilers, unless they have their own air supply). 

They must not be positioned close to curtains, armchairs, furniture or to other flammable materials. 

They must not be installed in explosive or potentially explosive environments which may become explosive due to the presence of machinery, materials or dust 

that can cause greenhouse gas emissions or which can easily ignite with sparks. Before starting to install the pellet stove, bear in mind that all the finishes or any 

beams in flammable material must be positioned at a safe distance and outside the area of irradiation of the product itself.  Also bear in mind that to avoid 

compromising correct operation of the appliance it is essential to create a recirculation of air inside its housing, which prevents overheating. This is possible by 

observing minimum distances and by creating ventilation holes. 

 

07.1 PROCEDURE FOR CORRECT PRODUCT INSTALLATION 

 

 

Once the product has been positioned, follow the instructions below: 

 

Remove the upper Top and the relative deflectors found below. Also remove the galvanised covers on your left.   

 

Loosen all the hexagonal screws that keep the flue gas closed. Remove the vermiculite pieces found below. 

 

Remove the 3 caps that you find in the fume fan.  They are used to fill the tank with sand. (FIG.1). 

 

Open a small portion of the sandbag by cutting the corner using a pair of scissors (FIG.2). 

 

 

10

Содержание Cesare

Страница 1: ...INSTRUCTION MANUAL STORAGE STOVES COSTANZA EN...

Страница 2: ...facilitate stove s ignition 6 Should any anomaly concerning the flame be detected or however in any other case NEVER SWITCH OFF the stove by disconnecting it from the mains Use the relevant button Dis...

Страница 3: ...STALLATION WARNINGS p 8 07 INSTALLATION p 10 07 1 PROCEDURE FOR CORRECT PRODUCT INSTALLATION p 10 07 2 ELECTRICAL CONNECTIONS p 12 07 3 EXTERNAL THERMOSTAT p 12 07 4 IGNITION p 12 08 PRODUCT USE p 12...

Страница 4: ...technician Should the power supply cable be damaged it can be replaced only by the manufacturer or by its technical assistance service or by a similarly qualified person Do not place any object on th...

Страница 5: ...he appliance will be automatically switched off It may take two separate ignitions to resume operation at ideal working conditions since the Auger tube is very long CAUTION If the stove is not properl...

Страница 6: ...uisiti minimi del tiraggio del camino Pa 12 11 Flue gas temperature Fume temperature C 156 5 83 6 Flue gas temperature at flue spigot or socket Temperatura uscita fumi C 167 3 76 9 Flue gas mass flow...

Страница 7: ...the flue pipe must be carried out in a workmanlike manner and according to European UNI 10683 and national regulations local regulations and the technical specifications and warnings contained in this...

Страница 8: ...n be no bottlenecks No constrictions Use 10cm thick insulating thimbles if pipe vent passes through floors The flue pipe must be insulated along its entire length The insulation will make it possible...

Страница 9: ...f a flue pipe rain fog snow altitude but the most important is the wind which can cause negative thermal pressure as well as dynamic negative pressure The wind action varies depending on whether it is...

Страница 10: ...ENCY OF THE STOVE ENSURE THE FOLLOWING TYPES OF INSTALLATION BEFORE CONNECTION TO THE FLUE PIPE INSTALL THE PRODUCT WITH AT LEAST ONE T AND 1 METERS OF PIPE CERTIFIED ACCORDING TO EN 1856 2 06 INSTALL...

Страница 11: ...d therefore there must not be any open flame apparatus in the same room with the exception of type C boilers airtight Make sure that the stove can draw the necessary quantity of combustion air this mu...

Страница 12: ...hazard such as sheds garages storerooms for combustible materials etc These air intakes must be created in such a way that they cannot be obstructed neither from the inside nor from the outside and m...

Страница 13: ...distribution of the material shake and wiggle the machine during the filling phase to fill every single gap There are 8 sandbags at your disposal Correct filling guarantees the use of all the bags sup...

Страница 14: ...ean Do not use pellets of poor quality The use of substandard pellets can prevent the stove from reaching its maximum yield due to poor combustion and degradation of the stove itself Check that the do...

Страница 15: ...utton to access the menu It includes several items and levels to access settings and control board programming USER MENU The table below briefly describes the menu structure focusing in particular on...

Страница 16: ...n menu STOVE STATUS Enter the STOVE STATUS menu after pressing the P4 button the display scrolls the status of a number of variables during operation of the stove at work menu TECHNICAL This menu item...

Страница 17: ...t value Set temperature value the stove will go back to the Work mode and to the previously set heat output Set heat output If there is an external thermostat and the room temperature has been set to...

Страница 18: ...larm status can be reset by pressing the P3 button Safety thermostat In the event that the general safety thermostat detects a water temperature above the threshold the same intervenes to disconnect t...

Страница 19: ...09 CONNECTIONS 17...

Страница 20: ...use a dry cloth to clean the stove Do not use abrasive material or products that could corrode or bleach surfaces At the end of the season with the last ignition the pellet remaining in the auger must...

Страница 21: ...E RESTARTS IN WORKING MODE FIRE PIT CLEANING WARNING APPEARS AFTER 8 HOURS OF STOVE OPERATION 4 5 KW MODELS ONLY 8 HOURS ARE CUMULATIVE TO CLEAR THE WARNING PRESS ALL 3 BUTTONS ON THE DISPLAY FOR 4 5...

Страница 22: ...THE FIRE DOOR IS CLOSED CORRECTLY CALL TECHNICAL SUPPORT THERM DOOR SAFETY ALARM THERMAL SAFETY THERMOSTAT OR FIRE DOOR OPEN CLOSED INCORRECTLY LET THE STOVE COOL RE ARM THE MANUAL THERMOSTAT AT THE R...

Страница 23: ...tenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ____________ Tech...

Страница 24: ...ion needed to correctly use operate and perform maintenance on the appliance CUSTOMER Signature DEALER INSTALLER Signature Copy of the dealer or installer CERTIFICATE OF INSTALLATION AND TESTING CUSTO...

Страница 25: ...cs of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness any small cracks or cracks that could be highli...

Страница 26: ...sponsibility for such disposal is to be borne by the owner and to not incur sanctions or adverse effects on the environment and health we recommend you contact the local administration the local waste...

Страница 27: ...tion totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vor...

Отзывы: