Basic System Setup
VoIP²ALL 8 - 16 - 24 Channel Gateway User Guide
www.eurotech-communication.com
15
Work by Time Table
- The Local SIM will register in the cellular network only when preset in the
Time Table. For details, see
Assigning a Local SIM to Work by Time Table
on page 21.
To set the Local SIM to register by default:
1)
On Main Toolbar, click
Ports
. On the left you will see list of all the ports.
2)
Select the
General
tab.
3)
In
Default SIM,
select
Local SIM work by default
.
4)
Click
Save
.
5)
On the Main Toolbar, click
Monitor
to view the status of the cellular ports
.
The following is a single port monitor. The number of monitors displayed depends on the number
of ports in the Gateway.
When the SIM is registered correctly, the port monitor appears in green.
3.1.4.2.
SIP CONFIGURATION
The Gateway has an internal SIP Server that is able to register up to 32 SIP clients. A SIP client can be
a:
VoIP phone
External SIP Server
IP PBX/Soft switch
By default, the internal SIP Server works without authentication. You can register without a password
and choose any user name. The user name must be a number.
To configure YOUR SIP to send calls to the Gateway without registration
1)
Open
YOUR
SIP Configuration in the external
SIP Server
or
IP PBX
.
2)
Configure your SIP to send calls to the Gateway, according to the following parameters:
The
SIP Server IP Address
- the IP address of the Gateway
The
SIP User ID
(optional) - the defined user name for this SIP client
The
Authentication Password
(optional) - the defined password for this SIP client
3)
Save the configuration settings.
3.1.4.3.
PREFIX CONFIGURATION (CALL HANDLING)
Each port can have a list of defined prefixes. When a number is dialed, the Gateway checks the prefix
table and routes the call to a port according to the dialed prefix. The first matched prefix on the list is
selected.
If more than one port has a matching prefix, the Gateway creates a prefix group of these ports and
divides calls with this prefix amongst the group.