8. Fault alarm and countermeasures
JI150 can provide effective protection when the equipment performance is played fully. In case of abnormal fault, the
protection function will be invoked, the inverter will stop output, and the faulty relay contact of the inverter will start, and
the fault code will be displayed on the display panel of the inverter. Before consulting the service department, user can
perform self-check , analyze the fault cause and find out the solution according to the instructions of this chapter. If the
fault is caused by the reasons as described in the dotted frame, please consult the agents of inverter or directly contact
with our company.
No. Fault ID
Failure type
Possible causes
Solutions
1
Err.01
Inverter unit
protection
1. The short circuit of inverter output happens
2. The wiring for the motor and the inverter is too long
3. Module overheating
4. The internal wiring of inverter is loose
5. The main control panel is abnormal
6. The drive panel is abnormal.
7. The inverter module is abnormal
1. Eliminate peripheral faults
2. Additionally install the reactor or the output filter
3. Check the air duct is blocked or not and the
fan is working normally or not, and eliminate
problems
4. Correctly plug all cables
5. Seek for technical support
2
Err.02
Acceleration
overcurrent
1. The acceleration time is too short
2. Manual torque boost or V/F curve is not suitable
3. The voltage is low
4. The short-circuit or earthing of inverter output
happens
5. The control mode is vector and without identification
of parameters
6. The motor that is rotating is started
unexpectedly.
7. Suddenly increase the load in the process of
acceleration.
8. The type selection of inverter is small
1. Increase acceleration time
2. Adjust manual torque boost or V/F curve
3. Set the voltage to the normal range
4. Eliminate peripheral faults
5. Perform identification for the motor parameters
6. Select Speed Tracking Start or restart after
stopping the motor.
7. Cancel the sudden load
8. Choose the inverter with large power level
3
Err.03
Deceleration
overcurrent
1. The short-circuit or earthing of inverter output
happens
2. The control mode is vector and without identification
of parameters
3. The deceleration time is too short
4. The voltage is low
5. Suddenly increase the load in the process of
deceleration.
6. didn’t install braking unit and braking resistor
1. Eliminate peripheral faults
2. Perform identification for the motor parameters
3. Increase the deceleration time
4. Set the voltage to the normal range
5. Cancel the sudden load
6. Install braking unit and brake resistor
4
Err.04
Constant speed
overcurrent
1. The short-circuit or earthing of inverter output
happens
2. The control mode is vector and without identification
of parameters
3. The voltage is low
4, Whether suddenly increase the load when running
5. The type selection of inverter is small
1. Eliminate peripheral faults
2. Perform identification for the motor parameters
3. Set the voltage to the normal range
4. Cancel the sudden load
5. Choose the inverter with large power level
5
Err.05
Acceleration
overvoltage
1. Didn’t install braking unit and braking resistor
2. The input voltage is high
3. There is external force to drag the motor to run when
accelerating.
4. The acceleration time is too short
1. Install braking unit and brake resistor
2. Set the voltage to the normal range
3. Cancel the external force or install braking
resistor.
4. Increase acceleration time
6
Err.06
Deceleration
overvoltage
1. The input voltage is high
2. There is external force to drag the motor to run when
decelerating.
3. The deceleration time is too short
4. Didn’t install braking unit and braking resistor
1. Set the voltage to the normal range
2. Cancel the external force or install braking
resistor.
3. Increase the deceleration time
4. Install braking unit and brake resistor
7
Err.07
Constant speed
overvoltage
1. There is external force to drag the motor to run when
running
2. The input voltage is high
1. Cancel the external force or install braking
resistor.
2. Set the voltage to the normal range
8
Err.08
Control power
failure
The range of input voltage is not within the specification
Adjust the voltage to the range of the requirements
of specification
9
Err.09
Under voltage fault
1. The momentary power cut
2. The inverter’s input voltage is not within the
specification
3. The bus voltage is not normal
4. The rectifier bridge and buffer resistance are abnormal
5. The drive panel is abnormal.
6. The control panel is abnormal
1. Reset fault
2. Adjust the voltage to the normal range
3. Seek for technical support