Fb group Control parameter optimization group
Code
Parameter name
Setting range
Factory setting Change
Fb.00
Fast current limiting manner
0: Disable; 1: Enable
1
☆
Fb.01
Undervoltage point setting
50.0% ~ 140.0%
100.0%
☆
Fb.02
Overvoltage point setting
200.0 ~ 2500.0V
-
★
Fb.03
Deadband compensation mode
selection
0: No compensation;
1: Compensation mode 1;
2: Compensation mode 2
1
☆
Fb.04
Current detection compensation
0 ~ 100
5
☆
Fb.05
Vector optimization without PG mode
selection
0: No compensation;
1: Compensation mode 1;
2: Compensation mode 2
1
★
Fb.06
Upper limiting frequency for DPWM
switching
0.00 ~ 15.00Hz
12.00Hz
☆
Fb.07
PWM modulation mode
0: Asynchronous; 1: Synchronous
0
☆
Fb.08
Random PWM depth
0: Invalid
1 ~10:PWM carrier frequency random depth
0
☆
E0 group Wobbulate, fixed-length and counting group
Code
Parameter name
Setting range
Factory setting Change
E0.00
Swing setting manner
0: Relative to center frequency;
1: Relative to maximum Frequency
0
☆
E0.01
Wobbulate range
0.0% ~ 100.0%
0.0%
☆
E0.02
Sudden jump frequency range
0.0% ~ 50.0%
0.0%
☆
E0.03
Wobbulate cycle
0.1s ~ 3000.0s
10.0s
☆
E0.04
Triangle wave rise time coefficient
0.1% ~ 100.0%
50.0%
☆
E0.05
Set length
0m ~ 65535m
1000m
☆
E0.06
Actual length
0m ~ 65535m
0m
☆
E0.07
Pulse per meter
0.1 ~ 6553.5
100.0
☆
E0.08
Set count value
1 ~ 65535
1000
☆
E0.09
Specified count value
1 ~ 65535
1000
☆