E1 group Multi-speed, sample PLC parameter
Code
Parameter name
Setting range
Factory setting Change
E1.00
0 stage speed setting 0X
-100.0%
~
100.0%
0.0%
☆
E1.01
1 stage speed setting 1X
-100.0%
~
100.0%
0.0%
☆
E1.02
2 stage speed setting 2X
-100.0%
~
100.0%
0.0%
☆
E1.03
3 stage speed setting 3X
-100.0%
~
100.0%
0.0%
☆
E1.04
4 stage speed setting 4X
-100.0%
~
100.0%
0.0%
☆
E1.05
5 stage speed setting 5X
-100.0%
~
100.0%
0.0%
☆
E1.06
6 stage speed setting 6X
-100.0%
~
100.0%
0.0%
☆
E1.07
7 stage speed setting 7X
-100.0%
~
100.0%
0.0%
☆
E1.08
8 stage speed setting 8X
-100.0%
~
100.0%
0.0%
☆
E1.09
9 stage speed setting 9X
-100.0%
~
100.0%
0.0%
☆
E1.10
10 stage speed setting 10X
-100.0%
~
100.0%
0.0%
☆
E1.11
11 stage speed setting 11X
-100.0%
~
100.0%
0.0%
☆
E1.12
12 stage speed setting 12X
-100.0%
~
100.0%
0.0%
☆
E1.13
13 stage speed setting 13X
-100.0%
~
100.0%
0.0%
☆
E1.14
14 stage speed setting 14X
-100.0%
~
100.0%
0.0%
☆
E1.15
15 stage speed setting 15X
-100.0%
~
100.0%
0.0%
☆
E1.16
PLC Simple PLC running mode
0: Stop after single running;
1: Hold final value after single
2: Circulating
0
☆
E1.17
PLCmemory selection
Units:power-down memory;
0: Power-down without memory;
1: Power-down memory;
Tens:stop with memory;;
0: Stop without memory; 1:Stop memory
11
☆
E1.18
0 stage running time ~
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.19
0 stage ac/deceleration time selection
0: F0.13, F0.14; 1: F7.08, F7.09;
2: F7.10, F7.11; 3: F7.12, F7.13
0
☆
E1.20
1 stage running time T1
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.21
1 stage ac/deceleration time selection
Same to E1.19
0
☆
E1.22
2 stage running time T2
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.23
2 stage ac/deceleration time selection
Same to E1.19
0
☆
E1.24
3 stage running time T3
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.25
3 stage ac/deceleration time selection
Same to E1.19
0
☆
E1.26
4 stage running time T4
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.27
4 stage ac/deceleration time selection
Same to E1.19
0
☆
E1.28
5 stage running time T5
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.29
5 stage ac/deceleration time selection
Same to E1.19
0
☆
E1.30
6 stage running time T6
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.31
6 stage ac/deceleration time selection
Same to E1.19
0
☆
E1.32
7 stage running time T7
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.33
7 stage ac/deceleration time selection
Same to E1.19
0
☆
E1.34
8 stage running time T8
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.35
8 stage ac/deceleration time selection
Same to E1.19
0
☆
E1.36
9 stage running time T9
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.37
9 stage ac/deceleration time selection
Same to E1.19
0
☆
E1.38
10 stage running time T10
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.39
10 stage ac/deceleration time selection Same to E1.19
0
☆
E1.40
11 stage running time T11
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.41
11 stage ac/deceleration time selection Same to E1.19
0
☆
E1.42
12 stage running time T12
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.43
12 stage ac/deceleration time selection Same to E1.19
0
☆
E1.44
13 stage running time T13
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.45
13 stage ac/deceleration time selection Same to E1.19
0
☆
E1.46
14 stage running time T14
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.47
14 stage ac/deceleration time selection Same to E1.19
0
☆
E1.48
15 stage running time T15
0.0s(h) ~ 6500.0s(h)
0.0s(h)
☆
E1.49
15 stage ac/deceleration time selection Same to E1.19
0
☆
E1.50
Simple PLC run-time unit
0: S(s); 1: H(h)
0
☆
E1.51
Multi-stage command 0 reference
manner
0: Function code E1.00 reference
1: Analog AI1 reference;
5: PID control setting;
6: Keyboard set frequency (F0.01) setting,
UP/DOWN can be modified
0
☆