b0 group Motor parameters
Code
Parameter name
Setting range
Factory setting
Change
b0.00
Motor type selection
0: General asynchronous motor
1: Asynchronous inverter motor
0
★
b0.01
Rated power
0.1kW to 1000.0kW
Depends on models
★
b0.02
Rated voltage
1V to 2000V
Depends on models
★
b0.03
Rated current
0.01A to 655.35A (Inverter power
≦
55kW);
0.1A to 6553.5A (Inverter rate> 55kW)
Depends on models
★
b0.04
Rated frequency
0.01Hz to F0.19 (Maximum frequency)
Depends on models
★
b0.05
Rated speed
1rpm to 36000rpm
Depends on models
★
b0.06
Asynchronous motor stator resistance
0.001Ω to 65.535Ω (Inverter power <= 55kW)
0.0001Ω to 6.5535Ω (Inverter power> 55kW)
Motor parameters
★
b0.07
Asynchronous motor rotor resistance
0.001Ω to 65.535Ω (Inverter power <= 55kW)
0.0001Ω to 6.5535Ω (Inverter power> 55kW)
Motor parameters
★
b0.08
Asynchronous motor leakage
inductance
0.01mH to 655.35mH (inverter power <= 55kW)
0.001mH to 65.535mH (inverter power> 55kW)
Motor parameters
★
b0.09
Asynchronous motor mutual
inductance
0.1mH to 6553.5mH (Inverter power <= 55kW)
0.01mH to 655.35mH (Inverter power> 55kW)
Motor parameters
★
b0.10
Asynchronous motor no-load current
0.01A to b0.03 (Inverter power <= 55kW)
0.1A to b0.03 (Inverter power> 55kW)
Motor parameters
★
b0.27
Motor parameter auto tunning
0: No operation
1: Asynchronous motor parameters still auto tuning
2: Asynchronous motor parameters comprehensive auto tunning
0
★
y0 group Function code management
Code
Parameter name
Setting range
Factory setting
Change
y0.00
Parameter initialization
0: No operation
1:Restore default parameter values, not including motor
parameters
2: Clear history
3: Restore default parameter values, including motor parameters
4: Backup current user parameters
5: Restore from backup user parameters
0
★
y0.01
User password
0 to 65535
0
☆
y0.02
Function parameter group display
selection
Units digit: d group display selection
0: Not displays 1: Displays
Tens digit: E group display selection(The same above)
Hundreds digit:b group display selection(The same above)
Thousands digit:y group display selection(The same above)
Tens thousands digit:L group display selection(The same above)
11111
★
y0.03
Personality parameter group display
selection
Units digit:Reserved
Tens digit :User’s change parameter display selection
0:Not display 1:Display
00
☆
y0.04
Function code modification properties
0: Modifiable
1: Not modifiable
0
☆