b0 group  Motor parameters

Code

Parameter name

Setting range

Factory setting

Change

b0.00

Motor type selection

0:  General asynchronous motor
1:  Asynchronous inverter motor

0

b0.01

Rated power

0.1kW to 1000.0kW

Depends on models

b0.02

Rated voltage

1V to 2000V

Depends on models

b0.03

Rated current

0.01A to 655.35A (Inverter power 

 55kW);

0.1A to 6553.5A (Inverter rate> 55kW)

Depends on models

b0.04

Rated frequency

0.01Hz to F0.19 (Maximum frequency)

Depends on models

b0.05

Rated speed

1rpm to 36000rpm

Depends on models

b0.06

Asynchronous motor stator resistance

0.001Ω to 65.535Ω (Inverter power <= 55kW)
0.0001Ω to 6.5535Ω (Inverter power> 55kW)

Motor parameters

b0.07

Asynchronous motor rotor resistance

0.001Ω to 65.535Ω (Inverter power <= 55kW)
0.0001Ω to 6.5535Ω (Inverter power> 55kW)

Motor parameters

b0.08

Asynchronous motor leakage 
inductance

0.01mH to 655.35mH (inverter power <= 55kW)
0.001mH to 65.535mH (inverter power> 55kW)

Motor parameters

b0.09

Asynchronous motor mutual 
inductance

0.1mH to 6553.5mH (Inverter power <= 55kW)
0.01mH to 655.35mH (Inverter power> 55kW)

Motor parameters

b0.10

Asynchronous motor no-load current

0.01A to b0.03 (Inverter power <= 55kW)
0.1A to b0.03 (Inverter power> 55kW)

Motor parameters

b0.27

Motor parameter auto tunning

0:  No operation
1:  Asynchronous motor parameters still auto tuning
2:  Asynchronous motor parameters comprehensive auto tunning

0

y0 group  Function code management

Code

Parameter name

Setting range

Factory setting

Change

y0.00

Parameter initialization

0: No operation
1:Restore default parameter values, not including motor 
parameters
2: Clear history
3: Restore default parameter values, including motor parameters
4: Backup current user parameters
5: Restore from backup user parameters

0

y0.01

User password

0 to 65535

0

y0.02

Function parameter group display 
selection

Units digit: d group display selection
0: Not displays       1: Displays
Tens digit: E group display selection(The same above)
Hundreds digit:b group display selection(The same above)
Thousands digit:y group display selection(The same above)
Tens thousands digit:L group display selection(The same above)

11111

y0.03

Personality parameter group display 
selection 

Units digit:Reserved
Tens digit :User’s change parameter display selection
0:Not display                1:Display

00

y0.04

Function code modification properties

0: Modifiable
1: Not modifiable

0

Содержание JI150

Страница 1: ...www euronormdrives com info euronorm nl 31 0 252 228850 Frequency Drive JI150 Manual...

Страница 2: ...terminals 11 F2 group Output terminal 13 F3 group Start and stop control group 14 F4 group V F control parameter group 15 F5 group Vector control parameter group 15 F6 group Keyboard and display 16 F7...

Страница 3: ...requency inverter The diagrams of these operating instructions are used for convenience of explanation and may be slightly different from the product due to product upgrades Please take this manual to...

Страница 4: ...installation position mm Weight kg L W H A B d E JI150 0R7G4 Z 0 75 138 72 123 5 127 61 5 62 1 1 JI150 1R5G4 Z 1 5 JI150 2R2G4 Z 2 2 JI150 004G4 Z 4 185 72 134 175 45 5 82 1 3 JI150 5R5G4 Z 5 5 0 75 5...

Страница 5: ...ance vector control inverter based on DSP Control method V F control vector control W O PG Automatic torque boost function Realize low frequency 1Hz and large output torque control under the V F contr...

Страница 6: ...trol Jog frequency range 0 00Hz to max frequency jog Ac deceleration time 0 0 6500 0s Built in PID Easy to realize closed loop control system for the process control Automatic voltage regulation AVR A...

Страница 7: ...n At most save three error message and the time type voltage current frequency and work status can be queried when the failure is occurred Key lock and function selection Lock part or all of keys defi...

Страница 8: ...wiring requirements correct selection of accessories such as Voltmeter input power supply etc After completing the wiring please check it correctly and make sure that it is correct before powering it...

Страница 9: ...put status DO output status d0 09 AI1 voltage AI1 input voltage value 0 01V d0 12 Count value Actual pulse count value in counting function d0 13 Length value Actual length in fixed length function d0...

Страница 10: ...nning 0 Running frequency 1 Set frequency 0 F0 11 Command source selection Keyboard control LED off 1 Terminal block control LED on 2 Communications command control LED flashes 3 Keyboard control Comm...

Страница 11: ...rminal 1 The setting of 16 stage speed or 16 kinds of other command can be achieved through the 16 states of the four terminals 13 Multi speed terminal 2 14 Multi speed terminal 3 15 Multi speed termi...

Страница 12: ...then switches directly to DC braking status 50 Clear current running time If the terminal is valid the inverter s current running time is cleared Table 1 Multi command functions description Over 4 se...

Страница 13: ...Ready to run When the inverter main circuit and control circuit power supply has stabilized and the drive does not detect any fault information the drive is in an operational state output ON signal 1...

Страница 14: ...Relay 1 output delay time 0 0s 3600 0s 0 0s F2 15 DO terminal active status selection Units digit Reserve Tens digit Relay 0 Positive 1 Negtive 00000 F2 16 DA1 zero bias coefficient 100 0 100 0 20 0...

Страница 15: ...00 80 F4 11 V F oscillation suppression gain 0 100 0 F4 12 V F separation voltage source 0 9 0 F4 13 V F separation voltage digital setting 0V motor rated voltage 0V F4 14 V F separation voltage rise...

Страница 16: ...F6 06 Inverter module radiator temperature 0 0 100 0 F6 07 Total running time 0h 65535h F6 08 Total power on time 0h 65535h F6 09 Total power consumption 0 65535 F6 10 Product number Inverter product...

Страница 17: ...22 Start protection selection 0 OFF 1 ON 0 F7 23 FDT1 detection value 0 00Hz F0 19 Max frequency 50 00Hz F7 24 FDT1 detection hysteresis value 0 0 100 0 FDT1 level 5 0 F7 25 Frequency reaches detectio...

Страница 18: ...8 12 Automatic fault reset 0 1s 100 0s 1 0s F8 25 Abnormal reserve frequency 60 0 100 0 100 F8 26 Momentary power cut action selection 0 Invalid 1 Deceleration 2 Deceleration and stop 0 F8 28 Recovery...

Страница 19: ...on 1 Compensation mode 1 2 Compensation mode 2 1 Fb 06 Upper limiting frequency for DPWM switching 0 00 15 00Hz 12 00Hz Fb 07 PWM modulation mode 0 Asynchronous 1 Synchronous 0 Fb 08 Random PWM depth...

Страница 20: ...2 stage ac deceleration time selection Same to E1 19 0 E1 24 3 stage running time T3 0 0s h 6500 0s h 0 0s h E1 25 3 stage ac deceleration time selection Same to E1 19 0 E1 26 4 stage running time T4...

Страница 21: ...l gain KP1 0 0 to 200 0 80 0 E2 14 Integration time Ti1 0 01s to 10 00s 0 50s E2 15 Differential time Td1 0 00s to 10 000s 0 000s E2 16 Proportional gain KP2 0 0 to 200 0 20 0 E2 17 Integration time T...

Страница 22: ...rter power 55kW 0 01mH to 655 35mH Inverter power 55kW Motor parameters b0 10 Asynchronous motor no load current 0 01A to b0 03 Inverter power 55kW 0 1A to b0 03 Inverter power 55kW Motor parameters b...

Страница 23: ...back loss when running 40 Fast current limiting timeout 41 Switch motor when running 42 Too large speed deviation 43 Motor overspeed 45 Motor over temperature 51 Initial position error COF communicati...

Страница 24: ...ens 2 The control mode is vector and without identification of parameters 3 The deceleration time is too short 4 The voltage is low 5 Suddenly increase the load in the process of deceleration 6 didn t...

Страница 25: ...he existing problems in the peripheral line 2 replace the drive the power board or contactor 18 Err 18 Current detection fault 1 Check Hall device 2 The drive panel is abnormal 1 Replace the drive pan...

Страница 26: ...___________________________________________________________________ ____________________________________________________________________________________________________________________________________...

Страница 27: ...Hub van Doorneweg 8 2171 KZ Sassenheim NL T 31 0 252 228850 F 31 0 252 228235 E sales euronorm nl I euronormdrives com 27 EURN010000_002_C Delivery program...

Страница 28: ...www euronormdrives com Hub van Doorneweg 8 Sassenheim...

Отзывы: