y1 group Fault query parameter group
Code
Parameter name
Setting range
Factory setting Change
y1.00
Type of the first fault
0: No fault
1: Inverter unit protection
2: Acceleration overcurrent
3: Deceleration overcurrent
4: Constant speed overcurrent
5: Acceleration overvoltage
6: Deceleration overvoltage
7: Constant speed overvoltage
8: Control power failure
9: Undervoltage
10: Inverter overload
11: Motor Overload
12: Input phase loss
13: Output phase loss
14: Module overheating
15: External fault
16: Communication abnormal
17: Contactor abnormal
18: Current detection abnormal
19: Motor self-learning abnormal
20: Encoder/PG card abnormal
21: Parameter read and write abnormal
22: Inverter hardware abnormal
23: Motor short to ground
24: Reserved
25: Reserved
26: Running time arrival
27: Custom fault 1
28: Custom fault 2
29: Power-on time arrival
30: Load drop
31: PID feedback loss when running
40: Fast current limiting timeout
41: Switch motor when running
42: Too large speed deviation
43: Motor overspeed
45: Motor over-temperature
51: Initial position error
COF: communication failure
-
●
y1.01
Type of the second fault
-
●
y1.02
Type of the third(At last) fault
-
●
y1.03
Frequency of the third(At last) fault
-
-
●
y1.04
Current of the third(At last) fault
-
-
●
y1.05
Bus voltage of the third(At last) fault
-
-
●
y1.06
Input terminal status of the third(At last) fault
-
-
●
y1.07
Output terminal status of the third(At last) fault
-
-
●
y1.08
Reserved
-
y1.09
Power-on time of the third(At last) fault
-
●
y1.10
Running time of the third(At last) fault
-
-
●
y1.13
Frequency of the second fault
-
●
y1.14
Current of the second fault
-
-
●
y1.15
Bus voltage of the second fault
-
-
●
y1.16
Input terminal status of the second fault
-
-
●
y1.17
Output terminal status of the second fault
-
-
●
y1.19
Power-on time of the second fault
-
●
y1.20
Running time of the second fault
-
-
●
y1.23
Frequency of the first fault
-
●
y1.24
Current of the first fault
-
-
●
y1.25
Bus voltage of the first fault
-
-
●
y1.26
Input terminal status of the first fault
-
-
●
y1.27
Output terminal status of the first fault
-
-
●
y1.29
Power-on time of the first fault
-
●
y1.30
Running time of the first fault
-
●