ERROR
*** 1(1)
Tank sensor upper
Type:
(See explananation)
Error must be fixed!
►
↓
Error
in
the
sensor
in
the
lower
section
of
the
tank.
This
type
of
error
can
be
either
a
short
circuit
or
a
failure
in
the
sensor
or
cable.
***
ERROR
*** 1(1)
No communication
with heat pump.
Error must be fixed!
►
↓
Communication
error
between
the
circuit
board
in
the
heat
pump
module
and
the
tank
section's
circuit
board.
Check
the
cabling
between
the
module
and
the
tank
section.
***
ERROR
*** 1(1)
Motor protector heat
pump cut out
Error must be fixed!
►
↓
Power
to
the
heat
pump
has
become
higher
than
normal.
This
can
have
various
causes.
Check
that
no
main
fuse
has
tripped.
***
ERROR
*** 1(1)
Wrong direction of
Water pipes to HP
Error must be fixed!
►
↓
This
alarm
may
be
due
to
the
hoses
from
the
heat
pump
module
to
the
tank
section
being
improperly
connected
or
due
to
one
of
the
water
sensors
on
the
heat
pump
showing
an
error.
***
ERROR
*** 1(1)
Phase L1 missing in
heat pump
Error must be fixed!
►
↓
This
error
occurs
because
one
phase
(L1)
is
missing
for
the
heat
pump
module.
Check
the
main
fuses.
***
ERROR
*** 1(1)
High pressure switch
Heat pump tripped
Error must be fixed!
►
↓
Error
occurs
because
the
pressure
in
the
heat
pump
module's
compressor
has
become
too
high.
Contact
the
service
department
in
the
event
of
repeated
alarms.
***
ERROR
*** 1(1)
Hot gas temperature
Heat pump too high
Error must be fixed!
►
↓
This
error
occurs
because
the
temperature
in
the
heat
pump's
compressor
has
become
too
high.
Contact
the
service
department
in
the
event
of
repeated
alarms.
***
ERROR
*** 1(1)
Hot gas temperature
heat pump too low
Error must be fixed!
►
↓
This
error
occurs
because
the
temperature
in
the
heat
pump's
compressor
is
too
low.
Contact
the
service
department
in
the
event
of
repeated
alarms.
***
ERROR
*** 1(1)
Tempdiff above heat
pump low
Error must be fixed!
►
The
alarm
indicates
that
the
temperature
increase
in
the
heat
pump
is
low
in
relation
to
the
flow
that
is
running
through
the
heat
pump
module.
Contact
the
service
department
in
the
event
of
repeated
alarms.
Only
displayed
if
heat
pump
module
is
installed