48
Power supply
The
power
supply
to
the
Exotic
Compact
is
connected
on
the
power
supply
terminals
up
and
to
the
left
of
the
connecting
plate.
Check
the
phase
sequence
before
connecting.
Based
on
the
maximum
power
requirements
for
the
system,
select
the
correct
fuse
and
cable
dimensions.
Max
fuse
for
the
product
is
32A.
The
electric
heater
can
be
blocked
in
stages
of
1.5
kW
in
order
to
limit
the
maximum
connected
power.
Installing
current
transformers
is
recommended
(accessories),
which
provides
automatic
control
of
the
maximum
power
based
on
a
main
fuse
in
the
system.
The
table
below
provides
a
rough
guide
to
power
usage
with
different
electric
heater
stages
connected
to
the
heat
pump.
Note
that
the
element
in
the
electric
heater
is
230
V,
and
if
current
transformers
are
installed
the
least
loaded
phase
will
be
selected.
Table
1.
Power
usage
by
heat
pump
at
different
power
settings
for
the
electric
heater.
Power
electric
heater
6.0
kW
7.5
kW
9.0
kW
10.5
kW
Phase
L1
L2
L3
L1
L2
L3
L1
L2
L3
L1
L2
L3
Without
a
heat
pump
module
9.2A
15.7A
9.2A
15.7A
9.2A
15.7A
Compact
5
13.5A
20.0A
13.5A
20.0A
13.5A
20.0A
Compact
8
14.4A
20.9A
14.4A
20.9A
14.4A
20.9A
Compact
10
15.9A
22.4A
15.9A
22.4A
15.9A
22.4A
Compact
12
16.9A
23.4A
16.9A
23.4A
16.9A
23.4A