Spare parts list  

 

 

Order

 

number

 

 

   

Compact

 

5

        

Compact

 

8

         

Compact

 

10

       

Compact

 

12

 

Compressor

 

 

521240500

 

520933800

 

520969100

 

520879800

 

Receiver

 

drier

 

 

520837800

 

520837800

 

520837800

 

520837800

 

Evaporator

 

521204700

 

521204700

 

521241000

 

521241000

 

Condensor

 

521204800

 

521204800

 

521204800

 

521204800

 

Low

 

pressure

 

pressostate

 

521103900

 

521103900

 

521103900

 

521103900

 

High

 

pressure

 

pressostate

 

520930400

 

520930400

 

520930400

 

520930400

 

Sight

 

glass

 

 

520930800

 

520930800

 

520930800

 

520930800

 

Expansion

 

valve

 

521240600

 

521236700

 

521237100

 

521237100

 

C

 

pump

 

(HW)

 

521237900

 

521237900

 

521237900

 

521237900

 

C

pump

 

brine

 

521237900

 

521237900

 

521237900

 

521110300

 

Charge

 

pump

 

PWM

 

521110400

 

521110400

 

521110400

 

521110400

 

Contactor

 

(Heat

 

pump)

 

521079900

 

521079900

 

521079900

 

521079900

 

Transformer

 

15W

 

521233200

 

521233200

 

521233200

 

521233200

 

PCB

 

Heat

 

pump

 

521142500

 

521142500

 

521142500

 

521142500

 

Hot

 

gas

 

sensors

 

521137800

 

521137800

 

521137800

 

521137800

 

Outdoor

 

sensor

 

521137600

 

521137600

 

521137600

 

521137600

 

Room

 

sensor

 

521137500

 

521137500

 

521137500

 

521137500

 

Sensors

 

Tank,

 

Brine,

 

etc.

 

521138000

 

521138000

 

521138000

 

521138000

 

Flow

 

switch

 

521115700

 

521115700

 

521115700

 

521115700

 

Hot

 

water

 

exchanger

  

521028600

 

521028600

 

521028600

 

521028600

 

Changing

 

valve

 

521213000

 

521213000

 

521213000

 

521213000

 

Mixing

 

valve

 

BIV

 

521003400

 

521003400

 

521003400

 

521003400

 

Motor

 

mixing

 

valve

 

3347308

 

3347308

 

3347308

 

3347308

 

Electric

 

heater

 

(10.5

 

kW)

 

521029500

 

521029500

 

521029500

 

521029500

 

PCB

 

tank

 

unit

 

521125600

 

521125600

 

521125600

 

521125600

 

Display

 

tank

 

unit

 

521127000

 

521127000

 

521127000

 

521127000

 

Fuses

 

(HP/heater

 

16A)

 

521080500

 

521080500

 

521080500

 

521080500

 

Contactor

 

electric

 

heater

 

521079700

 

521079700

 

521079700

 

521079700

 

overheating

 

protection

 

110gr

 

521029600

 

521029600

 

521029600

 

521029600

 

Termostat

 

1pol

 

electric

 

heater

 

521232300

 

521232300

 

521232300

 

521232300

 

current

 

transformer

 

30VA

 

4663003

 

4663003

 

4663003

 

4663003

 

 

 

 

 

 

 

Содержание Exotic Compact 10

Страница 1: ...Exotic Compact C 1308 118 ver 1 3 EN Installation and user guide for Exotic Compact C For software version 1 4 With flow reduce valve...

Страница 2: ...tant 17 In practice 17 Hot water 18 Hot water settings 19 Base heat 21 Summer charging 21 Display 22 Overview 22 Menu modes 22 Menu modes 23 Adjust a setting 23 Menu tree 24 Main menu 24 Menu Settings...

Страница 3: ...erminal blocks 49 Block A 230V 49 Block B extra low voltage 50 Communication 1 2 50 Outdoor sensors 3 4 50 Room sensors 5 8 51 Current transformers 10 13 accessories 52 Error out 14 16 53 Digital inpu...

Страница 4: ...sis to the finished heat pump are monitored to continually maintain quality The chassis of the heat pump including all screws and rivets are manufactured from stainless steel which requires minimum ma...

Страница 5: ...nsor room sensor Safety regulations The following safety regulations must be observed when handling installing and using the product An omnipolar switch should be installed on the power supply cables...

Страница 6: ...lve HP return Cold water in cu22 Hot water out cu22 Drainage valve Brine in Circuit board for tank unit Fuses heat pump elec heater Contactor for electric heater Emergency heat switch Reset overheatin...

Страница 7: ...ndenser High pressure switch Service outlet high pressure Service outlet low pressure Low pressure switch Brine circulation pump Brine out Hot gas pipe Condenser Filter receiver Compressor Heat pump c...

Страница 8: ...this curve yourself It is important to make sure that the heating curve is set properly for your own comfort but also to ensure the overall efficiency of the heating system Upper tank section The upp...

Страница 9: ...oor heating system the water will not need to be as hot to achieve sufficient heating Based on all of these parameters which vary from house to house the settings will be unique in each case We call t...

Страница 10: ...outside the Exotic Compact unit sends 55 C water to the radiators When you adjust this point you change the angle of the entire heating curve The biggest changes occur when outdoor temperatures are co...

Страница 11: ...nt at all If you increase this value the curve moves upwards i e becomes warmer and if you reduce this value the temperature drops This setting is primarily used when you feel that it is too cold or w...

Страница 12: ...ouse During summer time when heat is in off mode both circulation pump and mixing valve which determines the temperature to the heating system will be run periodically in order to prevent sticking If...

Страница 13: ...or temperature is 0 C cracking the curve If you feel that there isn t enough heating when it is around 0 C outside but it is otherwise sufficient you can increase this setting somewhat Adjusting the c...

Страница 14: ...nit stops sending water to your heating system If you activate basement heating Exotic Compact will continue to send water at the temperature you set even if the outdoor temperature is high Activate b...

Страница 15: ...t unlock this function in the installer s menu in order for you to be able to view it Setting a maximum temperature also allows you to protect your underfloor heating system against excessively high t...

Страница 16: ...g For each 1 10 of a degree 0 1 C that the current room temperature deviates from the set temperature the temperature in your heating system drops by approximately 4 C Block temporarily The button pla...

Страница 17: ...s warmer than necessary and therefore has a lower degree of efficiency The best savings for your heating system come from setting the water temperatures as low as possible In practice It can take a lo...

Страница 18: ...ptimal savings How hot water is produced The Exotic Compact does not have any container or coils with hot water inside the tank but fresh hot water is produced continuously using a special hot water e...

Страница 19: ...time to try to heat the water in the upper tank When you use hot water from the Exotic Compact unit primarily when showering or filling the bathtub the temperature in the upper and lower section will...

Страница 20: ...or the heat pump to increase the tank temperature No electric heater is used for this function which implies lower costs Upper tank temperature You can set the temperature that you want to be maintain...

Страница 21: ...ring the summertime your house needs very little heating or none at all In order to increase the running time for the heat pump and increase the amount of domestic hot water in the summertime you can...

Страница 22: ...se up and down through the different menu trees but also to increase or decrease a value for the various settings Left right arrow Use the right arrow to move up one step in the menu tree when there a...

Страница 23: ...ngs submenu When you are in a settings display there is either a number or a yes no option All of the adjustable parameters have an arrow in front of them To activate the setting press the right arrow...

Страница 24: ...on time Service Settings This is where you can adjust the settings for the heating curve among other things and set the room temperature and the domestic hot water temperature etc Present values This...

Страница 25: ...ating and domestic hot water Function key Menu for setting of functions for the button on the room sensor Pool heating If the accessory Pool heating is installed this menu will be activated Please rea...

Страница 26: ...e 17C Heating curve point C indicates the outdoor temperature at which the heat should stop being sent mixed to the heating system Above this temperature the mixing closes completely and the radiator...

Страница 27: ...lower tank section so called floating condensation Since the lower section of the tank is used to preheat the hot water the temperature should not be too low Base heat is the lowest temperature to whi...

Страница 28: ...ave an open fireplace placed in the same room as the sensor When you add heat to the room with the fire place the sensor will stop the heat to the complete heating system i e all rooms will be affecte...

Страница 29: ...en the current value and the nominal value Only displayed if room sensors are installed Heating system 1 Heat ON OFF Act 36 2C Nom 35 7C Outdoor temp 11 1C Current information for your heating system...

Страница 30: ...6C Current status of the mixing valve motor which ensures that the right temperature is sent to your heating system The mixing motor opens and closes continuously so that the difference between the c...

Страница 31: ...of the 3 phases are being charged by the electric heater and with how much power During charging a signal will flash alternately between on and L1 2 3 In the display example on the right phase L1 is...

Страница 32: ...cheaterinit Before the heating system can take water energy from the upper tank section a certain length of time must have passed from when the need arose the standard is 3 hours This gives the heat p...

Страница 33: ...brine can have before the system stops and an alarm is triggered Your installer sets this parameter which depends on how much anti freeze liquid there is in the system Hot gas temp 95C Max allowed tmp...

Страница 34: ...code for the heat pump module in order for it to communicate correctly with the tank section Only displayed if the heat pump is installed Heat pump total ope ration 23547h Compressor total op ration 1...

Страница 35: ...p module it runs automatically as an electric boiler This display provides information about the electrical power that the electric heater is currently using Only displayed if heat pump is not install...

Страница 36: ...ection and the heat pump module charge pump will start to check the temperatures in order to optimise operations during startup This information appears in the display during that time SYSTEM OK Heat...

Страница 37: ...ated and 2 of the alarms are still active ERROR Error total 3 Active errors 2 Scroll with up down ERROR 1 3 Room sensor 1 Type Short circuit Error must be fixed ERROR 2 3 Brine in sensor Type Open Not...

Страница 38: ...sors used for measuring the amount of energy in your heating system This type of error can be either a short circuit or a failure in the sensor or cable Only displayed if the energy meter accessory is...

Страница 39: ...ipe in the heat pump module see the overview diagram at the beginning of this manual This type of error can be either a short circuit or a failure in the sensor or cable Only displayed if heat pump mo...

Страница 40: ...ase L1 missing in heat pump Error must be fixed Thiserroroccursbecauseonephase L1 ismissingfortheheatpump module Checkthemainfuses ERROR 1 1 High pressure switch Heat pump tripped Error must be fixed...

Страница 41: ...ller has set the lowest allowable temperature depending on how much anti freeze was used Contact the service department in the event of repeated alarms ERROR 1 1 Low flow brine circuit Error must be f...

Страница 42: ...basic design heating pipes are mounted for a top connection However both pipes can be easily reversed to allow for a bottom connection The flow line for the heating system is mounted directly on the m...

Страница 43: ...are designed with a cc measurement of 55 mm in order to make installing a combination of valves easy Note that the safety valve does not need to be installed as the exchanger volume is below 1 litre...

Страница 44: ...must be insulated to prevent ice or condensation from forming Brine fluid The brine medium should contain an antifreeze medium e g bio ethanol to maintain fluidity down to temperatures of 15 C Collec...

Страница 45: ...for brine medium CompletekitasshowncanbeorderedfromEuronom item no 1921062 No Description 1 Brine to heat pump in 2 Brine from heat pump out 3 Fill coupling including valves dirt filter 4 Safety valve...

Страница 46: ...ifference of 3 C between the brine in out is the ideal If the difference is too high the system will issue a low brine flow alarm The diagram below shows the drop in pressure for the evaporator and th...

Страница 47: ...e terminal blocks and how the connection should be set up The terminal blocks are divided into blocks called A B C D E and F Note that this manual only describes how to connect standard components i e...

Страница 48: ...m power based on a main fuse in the system The table below provides a rough guide to power usage with different electric heater stages connected to the heat pump Note that the element in the electric...

Страница 49: ...that the installation is correct by pulling hard on the cable See also the diagrams below Also note the marking on the adhesive sticker regarding the upper and lower connection Block A 230V The only...

Страница 50: ...catch to be opened tools are not needed Two spring loaded terminal blocks are located inside the sensor Press the release button and insert the stripped cable to make the connection Cable to the outd...

Страница 51: ...addition there is a button on the room sensor that can be used for different functions e g extra hot water which can be set in the display In order for the room sensor to work well the sensor should...

Страница 52: ...s that the 3 phases are distributed as evenly as possible Installing the current transformers is recommended but not required It is possible to limit the maximum electrical power for the electric heat...

Страница 53: ...er failure there is contact between 14 and 15 Error or power failure NC Normal operations NO Digital input 17 18 Connection named EXTRA DIGITAL IN on the adhesive sticker The input should be potential...

Страница 54: ...e selected language with the ENTER button After selecting the language you will come to menu where you can adjust the settings Use the arrow buttons to move to the following location Settings For the...

Страница 55: ...he need In the event of an alarm excessive temperature on the heat pump or when the compressor is blocked the time delay is lifted automatically Only displayed if heat pump module is installed Current...

Страница 56: ...heat pump is installed Language ENGLISH Setting the language for the display screen Factory reset WARNING ALL SETT INGS WILL BE LOST Reset No This menu is used to reset all of the settings to the fact...

Страница 57: ...menu is used primarily by service technicians and should not be used unless you have a thorough knowledge of the system Use the arrow buttons to move to the following location Settings Enter access co...

Страница 58: ...ine flow al arm when temp diff above 8C Alarm setting for low brine flow through the heat pump module i e the temperature differential is too large Max flow temperature from heat pump 58C Max allowed...

Страница 59: ...charge pump Integral min 5000 PI regulator charge pump Min flow 190 l h Note that the settings in the remaining displays should not be adjusted before contacting Euronom The charge pump that moves th...

Страница 60: ...53C C 15 2A D 12C E 14C F 115C G 16C H 99 I 1250l The number 1 in 1 5 indicates which display is shown 1 5 is the last alarm that was logged The letters A I have the following meanings according to th...

Страница 61: ...default offset value is always 0 0 C Settings Calibration Error logs Boiler Calibration Heat pump Manual operation Calibration Boiler Display Description Comments Tank sensor lower Actual 34 6C Offse...

Страница 62: ...mp sensor Actual 44 6C Offset 0 0C Calibrating primary flow temp sensor Return flow temp sensor Actual 30 6C Offset 0 0C Calibrating flow temp sensor Hot gas sensor Actual 94 3C Offset 0 0C Calibratin...

Страница 63: ...radiator pump for heating system 1 Circulation pump hot water exchanger Off On Manual operation of the circulation pump that moves the hot water through the hot water exchanger Mixing valve motor Heat...

Страница 64: ...heater stages 6 kW 2 kW phase and current value on current sensors L1 L2 and L3 When turning on the system the current will increase by about 8 7A per phase is current sensors are installed External...

Страница 65: ...26 48 0 98 3 5 1 5 91 35 1 38 28 44 1 100 3 3 0 5 65 36 1 33 30 40 5 102 3 1 1 5 40 37 1 28 32 37 2 104 2 9 2 5 17 38 1 24 34 34 2 106 2 8 3 4 95 39 1 19 36 31 5 108 2 6 4 4 73 40 1 15 38 29 1 110 2...

Страница 66: ...ve Extra connections 3 pc DN20 out Run as electric boiler Yes Connection brine Hose 28 mm connection right or left Pressure drop evaporator 1 3 kPa 2 2 kPa 3 2 kPa 4 3 kPa Pressure drop condenser 2 0...

Страница 67: ...uit aerated OK CUSTOMER Circulation in brine loop OK Name Speed circulation pump brine loop 1 2 3 Address Speed radiator pump if not variable _________ Postal address Fuse heat pump _________A Telepho...

Страница 68: ...68 Electrical diagram tank unit...

Страница 69: ...69...

Страница 70: ...70...

Страница 71: ...71 Electrical diagram heat pump module...

Страница 72: ...72...

Страница 73: ...2500 521142500 521142500 Hot gas sensors 521137800 521137800 521137800 521137800 Outdoor sensor 521137600 521137600 521137600 521137600 Room sensor 521137500 521137500 521137500 521137500 Sensors Tank...

Страница 74: ...74 Visiting and delivery address Franska v gen 12 393 56 KALMAR SWEDEN Telephon 46 0 480 221 20 Telefax 46 0 480 870 17 www euronom se info euronom se...

Отзывы: