61
Calibration
The
calibration
menu
is
used
to
adjust
the
value
on
the
sensor
up
or
down.
Note
that
calibration
should
only
be
performed
with
a
calibrated
temperature
instrument.
When
you
enter
the
calibration
menu,
a
submenu
appears
where
you
can
choose
to
calibrate
the
boiler
or
the
heat
pump
sensor.
All
of
the
calibration
displays
show
the
sensor's
current
values
as
well
as
the
current
offset,
i.e.
how
much
the
sensor
is
adjusted
and
in
which
direction.
The
default
offset
value
is
always
0.0
°
C
Settings
Calibration
Error logs
→
Boiler
→
Calibration
Heat pump
Manual operation
→
Calibration - Boiler
Display
Description
Comments
Tank sensor lower
Actual: 34.6C
Offset:
→
+0.0C
►
↓
Calibrating
the
lower
tank
sensor
Tank sensor upper
Actual: 54.6C
Offset:
→
+0.0C
►
↓
Calibrating
the
upper
tank
sensor
Flow temp sensor
Heat system (1)
Actual: 40.3
Offset:
→
+0.0C
►
↓
Calibrating
flow
line
temperature
sensor
(to
heating
system
1)
Room sensor (1)
Actual: 20.1C
Offset:
→
+0.0C
►
↓
Calibrating
room
sensor
(to
heating
system
1)
Outdoor sensor
Actual: -10.1C
Offset:
→
+0.0C
►
↓
Calibrating
outdoor
sensor
Current sensor L1
Actual: 12.2A
Offset:
→
+0.0A
Calibrating
current
sensor
L1