Eurogames Srl – Operation and maintenance handbook – BUMPER CAR & MINI BUMPER CAR
17
Protected Menu” parameters
The parameters included in the protected menu are the following: (some are not modifiable)
T.Counter=000000
Total coins counter. This counter cannot be reset (read only).
Effect=SPACE
This parameter selects the sound effect group type. This parameter depends on
sound module memory programming.
Coin-Mode=NORM
NORM:
to start the game the number of coins-match requested must be inserted. Coin
inserted during game play will be lost but counted by the counters.
ACC:
to start the game the number of coins-match requested must be inserted. Every
coin inserted during game play will increase game time.
AC P:
to start the game the number of coins-match requested must be inserted. Coins
inserted during game play are valid only if the requested coins for 1 extra game are
reached.
FreeCoins(0)=Off
This option enable the free play when “Coins” parameter is set to 0
W-Coin Count=No
If ‘YES’: when START is issued from the remote control, the coins counter will
increment as for normal coin insertion.
Low-Battery=On
This option enable the “LOW BATTERY” message when the game is over and
the battery voltage is low. The message is repeated every 7 seconds.
LoBat-Lev=005%
Battery level for “Low Battery” message. This value can be changed between
5% to 40% range.
Auto-Brake=On
If “OFF”: motor will not brake when accelerator pedal is released.
if “ON”: motor will brake following “Deceleration” parameter.
End-Brake=On
If “ON”: after game time is finished and after “EndBrakeDelay”, motor brake
for 3 seconds.
EndBrakeDelay=0s
Delay (seconds) after the game end to motor brake.
TelBrakeDelay=0s
Delay (seconds) after remote control STOP command to motor brake.
Stop Lamp=Flash
When the timer is in STOP condition this option selects if the lamp must flash
or not.
J1.15=Emergency
This option selects the J1.15 input function.
If set to "Emergency": the timer will be reset if the J1.15 is activated.
If set to "FreeCoins": the J1.15 will act as coin insert but when this input is
deactivated the timer will be reset.
If set to “S” the J1.15 input must be connected to the safety belt switch.
This option enables the safety belt security functions.