Dust Cup
Lever

1

2

Filter
Tube

3

Filter

6

Filter
Tube
Retainer

Seals

6

7

HOW TO MAINTAIN 

(continued)

NOTE: Turn off the switch and unplug the electrical cord before emptying

dust cup. Never operate the vacuum cleaner without the dust cup
and filters properly installed.

Emptying the Dust Cup:

It is clearly visible when the dust cup is full and needs emptying. Do not fill
above the maximum fill line on dust cup.

Remove dust cup from cleaner body, pull filter screen up and out of dust cup
and dump debris in a waste container.

Before reassembling the dust cup, clean the filter screen with a brush or rinse with clear water. It must
be thoroughly dry before reinstalling. Alignment features (circled above) on filter screen and dust cup
must be in position to reinstall. Filter screen will fit snugly in dust cup when properly installed.

FOR INSTRUCTIONS ON HOW TO REMOVE AND
REPLACE THE DUST CUP FROM THE CLEANER
BODY, SEE THE PREVIOUS PAGE.

 

To Replace Pre-Motor Tube Filter

5.

Slide the completely dry filter back up into the filter
tube. The yellow ring should fit snugly into the clear filter
tube.

 6. Place the bottom of the filter tube in the filter tube retainer

on dust cup platform, then push filter tube against the
base until it snaps into place. Make sure the seals in
the top of the dust cup compartment line up with both
the filter tube and dust cup.

 7. Slide the dust cup lever to the right to the engage

position. This will raise the dust cup platform and secure
the filter tube and dust cup.

 Use replacement motor filter, 71643.

Filter
Screen

Cleaning and Replacing Filters
Pre-Motor Tube Filter

Check the pre-motor filter each time the dust cup is emptied. The pre-motor filter removes the smallest dust paticles. Clean
or replace as needed to maintain maximum performance. Never operate without motor filter in place. Do not place the
filter frame, dust cup or pre-motor filter in a dishwasher.

Yellow

Ring

5

To Clean Pre-Motor Tube Filter

1. When facing the cleaner, slide the dust cup lever to the

left to the release position. The dust cup platform will
drop down releasing the filter tube.

2. Remove filter tube from dust cup platform by pulling out

and lifting up at the top.

3. Grasp the yellow handle in the bottom of the filter and

pull down out of filter tube. A twisting motion may help.

4. The filter can be cleaned by vacuuming with another

cleaner or can be rinsed under running tap water and
air dried. Filter must be thoroughly dry before using.

Содержание 4880 Series

Страница 1: ...placement of broken or missing items to be shipped direct to you call 1 800 438 7352 8 a m to 4 45 p m Central Standard Time Monday through Friday En Mexico llame al 5670 6169 Index Important Safeguar...

Страница 2: ...carrying capacity Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or vacuum cleaner with wet hands Do not put any obj...

Страница 3: ...brancher Ne pas d brancher en tirant sur le cordon Pour d brancher tenez la fiche et non le cordon Ne pas manipuler la fiche ou l aspirateur avec les mains mouill es Ne pas rien ins rer dans les ouver...

Страница 4: ...82 2886 Mexico 5670 6169 Canada 1 800 282 2886 If you prefer you can write to The Eureka Company Service Division 807 N Main Street Bloomington Illinois 61701 USA In Canada write to The Eureka Company...

Страница 5: ...to expose screw holes on cleaner See above 2 From rear of cleaner align handle with screw locations on cleaner Slide handle into position 3 Attach handle with the two screws provided in the assembly...

Страница 6: ...acing the cleaner slide the lever to the left to the release position The dust cup platform will drop down 10 Lift dust cup from the dust cup compartment Dust Cup Lever How to Replace the Cyclonic Dus...

Страница 7: ...erformance 9 Dust Cup Lever When facing cleaner slide the dust cup latch to the left release position to release dust cup and motor filter Slide the dust cup latch to the right to the engage position...

Страница 8: ...the cleaner in case of motor overheating If the cleaner suddenly turns off follow this procedure 1 Push rocker switch to off O position 2 Unplug cleaner 3 Check for source of overheating problem i e...

Страница 9: ...twisting motion Remove hose from hose retainers 2 Place desired accessory onto end of hose or wand Turn ridge end to center Push wands together Pull apart Grasp both wands near ridge Nested Extension...

Страница 10: ...threads from the brush roll so it continues brushing the carpet To maintain the most efficient cleaning the bristles must touch the carpet To test the bristle length hold a ruler against the underneat...

Страница 11: ...to the release position The dust cup platform will drop down 2 Slide dust cup out of the dust cup compartment Dust Cup Lever How to Replace the Cyclonic Dust Cup 1 See the above illustration When repl...

Страница 12: ...tube in the filter tube retainer on dust cup platform then push filter tube against the base until it snaps into place Make sure the seals in the top of the dust cup compartment line up with both the...

Страница 13: ...ter 1 Place HEPAfilter inside HEPAcompartment with rubber seal against the back of the compartment 2 Replace HEPA door Place tab on bottom of HEPA door into slot on cleaner and swing door up pushing a...

Страница 14: ...e twist lock clockwise to release from hose adapter 3 Clear base hose of any blockages 4 Reconnect base hose to hose adapter Place base hose in hose adapter and rotate twistlock counter clockwise to s...

Страница 15: ...n lock is in place Then fasten using a coin turning the quarterturn lock clockwise 13 Place accessory nozzle into hose adapter 15 10 11 12 13 How to Check for Blockages in Brush Roll Compartment 14 Re...

Страница 16: ...otor filter tube must be properly lined up with seals at the top of the dust cup compartment Headlight not working Light Bulb Replace light bulb Noise from the brush roll area Brush Roll Remove base p...

Страница 17: ...tice 5 50 Accessories Tools The Eureka Company P O Box 2799 Bloomington IL 61702 2799 Part No Qty Price USD Total ORDER FORM 1 03 Not applicable in Canada IMPORTANT Be sure to include your model type...

Страница 18: ......

Страница 19: ...pe and serial number from the data plate on the cleaner Further Limitations and Exclusions Any warranty that may be implied in connection with your purchase or use of the cleaner including any warrant...

Страница 20: ...ems in This Carton 1 hardware package 2 screws Questions Do Not Return To Store Call 1 800 282 2886 8 a m to 7 30 p m Central Standard Time Monday thru Friday and 10 a m to 6 30 p m Central Standard T...

Отзывы: