BGA ETA-H15 OPERATION MANUAL
Page19
component should be picked up from its center. As soon as the vacuum nozzle touches component, the
vacuum pump starts to work and pick up component.
2
.
Press Sucks key, prism auto judge stick out or not. Follow flow auto process.
PL-HEAD
(
suck
)
down
→
auto suck chip
→
PL-HEAD
(
suck
)
upward
→
prism auto stick out
→
manual
aligning
(
see follow step
)
.
3
.
Watch LCD picture satisfy our require or not, can adjust by keyboard, specific adjust refer to “control
box instruction”.
4
.
Unscrew the PCB Fixing Knobs on the PCB Fixture to open PCB Clamp Bar. Fix the soldered PCB on
the PCB Fixture and adjust PCB’s position. Make the Monitor display the image of soldering point, and
make the images of soldering point and component in the same position. It is convenient for adjusting.
After roughly adjusting, screw down Fixture Fixing Knob to lock PCB Fixture to prevent it from sliding
right and left.
5
.
Align the component with two Adjustment Knobs and two Micro-adjustment Knobs. Make the images of
component solder pins and the soldering point on PCB overlap.
6
.
Press Sucks key, auto place.
7. Align the component with two Adjustment Knobs and two Micro-adjustment Knobs. Make the images of
component solder pins and the soldering point on PCB overlap.
10
、
Equipment Maintenance
Remark:
For ensuring reliable function and maintenance of equipment, please use parts provided by original factory.
Please turn off power switch of each part and pull out power plug when not in use.
Note:
After cutting off the power supply, the housing is still very hot, so please don’t use any dangerous or
combustible solvent to clean it.
Clean parts:
Clean the dust on system with clean towel.
Suggest to use dry or wet towel to clean the equipment. Solder on the glass of Bottom Radiator can be
cleaned out with hard object. Please be careful not to break down the glass.
Clean the prism of PL camera with pledget and be careful not to scrape it.
Use the towel with cleaning oil to clean PCB fixture and orbit.
Replace Suction Pad:
If you want to replace the Suction Pad of IR System, please turn off power, and replace it after waiting for
vacuum suction nozzle and Top Heater to cool down.
Take Suction Pad out of suction nozzle downwards, and install a new one in opposite direction.
Note:
PL EA-H15 is a precise equipment. Please don’t make any changes to it. Otherwise the precision of this
equipment will be affected.
Содержание BGA ETA-H15
Страница 2: ......