background image

SITE PREPARATION GUIDE

NCR RealPOS 60

(

7601

)

Release 2.0

B005-0000-2012
Issue C

Содержание RealPOS 60

Страница 1: ...SITE PREPARATION GUIDE NCR RealPOS 60 7601 Release 2 0 B005 0000 2012 Issue C...

Страница 2: ...iceable parts Servicing should only be performed by a qualified service technician Fuse Replacement Warning For continued protection against risk of fire replace only with the same type and ratings of...

Страница 3: ...must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances Do not modify the plug provided if it will not fit the outlet have the...

Страница 4: ...iv...

Страница 5: ...Mount Dimensions 9 VESA Mounting Hole Dimensions 10 NCR 5954 15 Inch DynaKey Dimensions 11 Standard Remote Table Top Mount 5964 K030 K031 11 NCR 5964 K038 K039 Checkstand Mount 12 NCR 5943 LCD 5967 1...

Страница 6: ...25 Weights 26 Shipping Weight Estimate 26 Service Clearance Requirements 27 Airflow Requirements 29 Customer Enclosure 30 Electrical Requirements 31 7601 Terminal Power Requirements 31 Peripheral Powe...

Страница 7: ...GA Extension 38 Powered RS 232 5975 39 Dual Cash Drawer Y Cable 39 Ethernet 10 100 1000BaseT Cable 39 PS 2 Keyboard Extension Cable 39 RS 232 w Power 5945 5992 EPT 40 AC Power Cables 40 Appendix A Tra...

Страница 8: ...viii Revision Record Issue Date Remarks A Oct 2010 First Issue B Jul 2012 Updated Solid State Optimization chapter C Jun 2013 Release 2 0...

Страница 9: ...terminal because site preparation deficiencies may be difficult to detect and correct after installation A NCR 7601 system consists of separate pieces combined in a variety of configurations Certain...

Страница 10: ...s agent who is fully conversant with the special requirements of electronic equipment prepare the site The responsibility of ensuring that the site is prepared in compliance with this document remains...

Страница 11: ...r site requirements Provide and install all communications cables wall jacks special connectors and associated hardware Provide and install necessary power distribution boxes conduits grounds lightnin...

Страница 12: ...hrough their power cords If the peripheral is powered by the terminal and has no dedicated ground then all of the ESD energy is coupled into the port connection Some devices may require the use of an...

Страница 13: ...the temperature changes beyond the restrictions Temperature Parameter Restriction Operating 5 C to 40 C 41 F to 104 F dry bulb Storage 10 C to 50 C 14 F to 122 F three months Shipping 40 C to 60 C 40...

Страница 14: ...tipped The keyboard does not attach to the drawer unit and may slide off if the drawer unit is tipped Do not turn the operator or customer displays upside down while holding only the display mounting...

Страница 15: ...NCR RealPOS 60 Terminal Site Preparation 7 Dimensions NCR 7601 Terminal 7601 Terminal w Cable Cover...

Страница 16: ...8 NCR RealPOS 60 Terminal Site Preparation Vertical Mount Dimensions...

Страница 17: ...NCR RealPOS 60 Terminal Site Preparation 9 Flush Wall Mount Dimensions...

Страница 18: ...10 NCR RealPOS 60 Terminal Site Preparation VESA Mounting Hole Dimensions The bottom chassis of the 7601 has a VESA hole pattern 100 mm that can be used to mount the unit on any standard VESA mount...

Страница 19: ...NCR RealPOS 60 Terminal Site Preparation 11 NCR 5954 15 Inch DynaKey Dimensions Standard Remote Table Top Mount 5964 K030 K031...

Страница 20: ...The Checkstand Mount is fully adjustable between the minimum and maximum dimensions that are illustrated below The DynaKey can also be rotated right and left of center shown by approximately 90 degre...

Страница 21: ...NCR RealPOS 60 Terminal Site Preparation 13 NCR 5943 LCD 5967 12 Inch Touch LCD Dimensions NCR 5943 LCD 5967 15 Inch Touch LCD...

Страница 22: ...14 NCR RealPOS 60 Terminal Site Preparation NCR 5982 6 5 Inch LCD Dimensions...

Страница 23: ...NCR RealPOS 60 Terminal Site Preparation 15 NCR 5975 Graphical Remote Customer Display Dimensions...

Страница 24: ...Terminal Site Preparation Tall Pole Mount There are four different length posts available for the 5975 5976 displays in four inch increments Note Heights greater than 215 mm 8 5 in should be screwed t...

Страница 25: ...NCR RealPOS 60 Terminal Site Preparation 17 NCR 5976 Remote Customer Display Dimensions...

Страница 26: ...Terminal Site Preparation Tall Pole Mount There are four different length posts available for the 5975 5976 displays in four inch increments Note Heights greater than 215 mm 8 5 in should be screwed t...

Страница 27: ...NCR RealPOS 60 Terminal Site Preparation 19 Keyboard Dimensions NCR 5932 2xxx 64 Key PS 2 POS Keyboard NCR 5932 5xxx USB Big Ticket POS Keyboard...

Страница 28: ...20 NCR RealPOS 60 Terminal Site Preparation NCR 5932 65xx PS 2 Compact Keyboard NCR 5932 66xx USB Compact Keyboard...

Страница 29: ...NCR RealPOS 60 Terminal Site Preparation 21 Printer Dimensions NCR 7167 Thermal Receipt and Impact Slip Printer NCR 7168 Thermal Receipt and Impact Slip Printer...

Страница 30: ...22 NCR RealPOS 60 Terminal Site Preparation NCR 7197 Thermal Receipt Printer NCR 7198 Thermal Receipt Printer...

Страница 31: ...NCR RealPOS 60 Terminal Site Preparation 23 Cash Drawer Dimensions NCR 2181 Cash Drawer NCR 2183 Cash Drawer...

Страница 32: ...24 NCR RealPOS 60 Terminal Site Preparation NCR 2185 Flip Top Drawer NCR 2186 Compact Cash Drawer...

Страница 33: ...NCR RealPOS 60 Terminal Site Preparation 25 Power Supply Dimensions...

Страница 34: ...4 5 10 0 7168 Receipt Impact Printer 5 0 11 0 7198 Thermal Receipt Printer 2 2 4 9 Shipping Weight Estimate To obtain the total maximum weight of a specific configuration add the weights of the appro...

Страница 35: ...NCR RealPOS 60 Terminal Site Preparation 27 Service Clearance Requirements...

Страница 36: ...d mm in 7601 300 11 8 40 1 5 40 1 5 40 1 5 90 3 5 Keyboard 100 4 Cash Drawer 330 13 0 7172 Printer 325 13 300 12 0 100 4 25 1 7167 Printer 305 12 305 12 7168 Printer 305 12 305 12 7197 Printer 267 10...

Страница 37: ...NCR RealPOS 60 Terminal Site Preparation 29 Airflow Requirements Do not block the air vents on the terminal or peripherals These vents are necessary for cooling...

Страница 38: ...40 mm 1 5 inches of clearance on sides and top The enclosure must provide adequate ventilation The enclosure doors must be of a type that allows adequate airflow through the enclosure from front to ba...

Страница 39: ...cific power cord must be ordered separately Available NCR power cords are described in the System Cables section Peripheral Power Requirements The number of peripherals that the terminal can support i...

Страница 40: ...32 NCR RealPOS 60 Terminal Site Preparation Cable Routing Peripheral cable connectors are located on the rear of the unit There is an additional USB port located on the front of the terminal...

Страница 41: ...the terminal can be routed down through the opening in the top of the Cable Cover External cables are routed out the bottom of the Cable Cover System Cables Printer Cables Powered USB USB Printer 24V...

Страница 42: ...Only 19721 24V USB Host Terminal 23 0 mm 0 9 in 19 0 mm 0 75 in 497 0441156 1m 1432 C092 0010 497 0441157 4 m 1432 C092 0040 RS 232 9 Pin to 9 Pin 19722 9 pin D shell Receptacle 9 pin D shell Recepta...

Страница 43: ...Receptacle 25 pin D shell Plug 497 0407427 1 0 m 1416 C337 0010 497 0407429 4 m 1416 C337 0040 RS 232 Printer 63 5 mm 2 5 in Access Hole Diameters 38 mm 1 5 in RS 232 Host Terminal Scanner Cables RS 2...

Страница 44: ...497 0418650 3 0 m 1432 C644 0030 19729 7882 Scanner RS 232 19728 Scanner D Shell 9 Pin Receptacle Modular 10 Pin Plug 497 0419723 4 0 m 1416 C653 0040 RS 232 Host Terminal Access Hole Diameters 19 0 m...

Страница 45: ...0010 497 0445079 4 m 1432 C158 0040 Access Hole Diameters 19 0 mm 0 75 in 19 0 mm 0 75 in DVI to DVI 23939a 63 5 mm 2 5 in Access Hole Diameters 497 0446721 1 0 m 1432 C191 0010 497 0446722 4 0 m 143...

Страница 46: ...5966 23940a Power Display 497 0428512 4 m 1416 C851 0040 Powered USB Host Terminal Access Hole Diameters 19 0 mm 0 75 in 23 0 mm 0 9 in VGA Extension 28678 Access Hole Diameters 38 0 mm 1 5 in 38 0 m...

Страница 47: ...Drawer Y Cable 15808 497 0409394 0 6 m 1416 C372 0006 Cash DWR 1 Cash DWR 2 Ethernet 10 100 1000BaseT Cable Note The 7601 supports 10 100Base T Ethernet Modular 8 Pin Plug Modular 8 Pin Plug 497 0433...

Страница 48: ...nal 9 pin Mini DIN Plug AC Power Cables 1416 C325 0030 006 1009037 U S The following power cables not shown also have an IEC connection of 45 mm 006 8601011 SEV 006 8601012 U K 006 8601019 Australia 0...

Страница 49: ...ty problems are is not covered by the NCR Maintenance Agreement NCR accepts no liability for any such occurrence nor for its consequences When power transient suppression is required the suppressors u...

Страница 50: ...e downtime and extend the life of the RealPOS Retail Solution For sizing and product information please call NCR Site Preparation Services at 800 257 0458 The following product offerings are available...

Отзывы:

Похожие инструкции для RealPOS 60