BGA ETA-H15 OPERATION MANUAL
Page4
9
.
The operation of Camera on PL and IR alternates according to the movement of PL’s telescopic arm.
Brightness of IR camera is controlled by keyboard of PL.
Net weight
:
75kg
Packaging dimension
:
1050*800*880
(
mm
)
5.2 Technical Parameters
TL
:
Melting temperature of solder
T1
:
Heat preservation starting temperature of reflow soldering
T2
:
Heat preservation ending temperature of reflow soldering
T3
:
Peak value temperature of soldering and de-soldering
T0
:
Valve temperature: The lowest temperature of Bottom Heater when Top Heater heats up. T0<TB
TIR
:
The set temperature of bottom heater
TB
:
The real-time temperature of bottom heater
TC
:
The real-time temperature of top heater
S1
:
Heating time rising from T1 to T2
S2
:
Heating time rising from T2 to T3
S3
:
Heat preservation time of T3
IR ETA-H15 Rework System has ten working modes and its parameter can be changed according to
demand. The following eight data can be referred.
0
.
T1=120
℃
S1=50s T2=140
℃
S2=45s T3=195
℃
S3=15s TL=183
℃
TB=150
℃
T0=100
℃
1
.
T1=130
℃
S1=40s T2=145
℃
S2=45s T3=200
℃
S3=15s TL=183
℃
TB=160
℃
T0=150
℃
2
.
T1=140
℃
S1=30s T2=150
℃
S2=50s T3=200
℃
S3=20s TL=183
℃
TB=160
℃
T0=155
℃
3
.
T1=140
℃
S1=40s T2=150
℃
S2=50s T3=195
℃
S3=25s TL=183
℃
TB=165
℃
T0=160
℃
4
.
T1=160
℃
S1=50s T2=180
℃
S2=40s T3=230
℃
S3=15s TL=217
℃
TB=170
℃
T0=150
℃
5
.
T1=160
℃
S1=40s T2=175
℃
S2=50s T3=225
℃
S3=20s TL=217
℃
TB=180
℃
T0=170
℃
6
.
T1=170
℃
S1=40s T2=185
℃
S2=50s T3=228
℃
S3=20s TL=217
℃
TB=180
℃
T0=180
℃
7
.
T1=180
℃
S1=40s T2=185
℃
S2=50s T3=228
℃
S3=25s TL=217
℃
TB=190
℃
T0=185
℃
Содержание BGA ETA-H15
Страница 2: ......