93
in
S
tallation
The voltage between the phases and the
neutral is 230 V a.c. Between the lives there is
a voltage of 400 V.
If there is not a voltage
of 400 V between the lives, two wires have
been taken from the same live in the meter
cupboard and the hob must be connected
with two neutral wires, as indicated above
under 2 lives with 2 neutrals.
Install a
connecting bridge between the connection points
3-4. Your groups must be fused with at least
16 A (2x). The connecting power cable must have
a minimum core cross section of 2,5 mm
2
.
Special connections
1 phase connection (1 1N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c.
Install connecting bridges between connection
points 1-2 and 3-4. Your group must be protected
by a fuse of at least 32 A. The connecting power
cable must have a minimum core cross section of
6 mm
2
.
3-phase connection (3 a.c. 230 V / 50 Hz):
The voltage between the phases and the neutral is
230 V a.c. Install connecting bridges between the
connection points 3-4. Your groups must be fused
with at least 16 A (3x). The connecting power
cable must have a minimum core cross section of
2,5 mm
2
.
You can use the bridges provided on the
connecting block to make the required
interconnections as indicated in the preceding
illustrations.
Safety prescriptions
For the appliance to work well, it is important:
n
That there is sufficient ventilation to allow
the hob to cool down, in accordance with the
possibilities specified in this chapter.
n
The ventilation air drawn in by the hob must
not be warmer than 35 °C. Bear this in mind if
the oven is to be built in under the hob.
n
That the connecting cable hangs freely and is
not caught by a drawer.
n
The worktop should be a minimum of 2.8 cm
and a maximum of 5 cm thick.
n
The worktop is flat.
Power table
The appliance can be connected in the
following ways:
Common connections
2 lives with 2 neutrals connection
(2 2N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V
a.c. There may be a voltage of 0 V between the
phases if they are connected to the same phase
in the meter cupboard but also 400 V if they are
connected to 2 different phases.
Your groups must be fused with at least 16 A (2x).
The connecting power cable must have a minimum
core cross section of 2,5 mm
2
.
3 lives with 1 neutral connection
(3 1N a.c. 400 V / 50 Hz):
The voltage between the phases and the neutral
is 230 V a.c. There is a voltage of 400 V between
the lives. Fit a connecting bridge between the
connection points 3-4. Phase 3 carries no load.
Your groups must be fused with at least 16 A (3x).
The connecting power cable must have a minimum
core cross section of 2,5 mm
2
.
2 lives with 1 neutral connection
(2 1N a.c. 400 V / 50 Hz):
92
in
S
tallation
Type of hob
A361KZT
Induction
x
Electrical connection
230 V - 50 Hz
x
Maximum power cooking
zones
Front left
2300 W contin.
Rear left
1400 W contin
Rear right
2300 W contin
Front right
1400 W contin
Power connection
L1
3700 W
L2
3700 W
Total power connection
7400 W
4
3 2
1
2N a.c. 230V / 50 Hz
generators
right
appliance
internal
generators left
4
3 2
1
1N a.c. 400V / 50 Hz
appliance
internal
generators
right
generators left
4
3 2
1
3N a.c. 400 V / 50 Hz
appliance
internal
generators
right
generators left
4
3 2
1
1N a.c. 230V / 50 Hz
appliance
internal
generators
right
generators left
4
3 2
1
3 a.c. 230V / 50 Hz
appliance
internal
generators
right
generators left
Содержание A361KZT