Operating Instructions GMV2-K  

revised: 09.05.2019 

Rev.: 0 

 

 

 

Subject to change without prior notice

 

32 

 

Tip:

    

You can overwrite individual measured values before transmission by selecting another cell. The selected cell must be 

in 

the first row 

of the cell that you want to overwrite. Now you can transfer single measured values, a single data record, or 

all data records to the GMV2-K. 

 

In “Menu – Output – RS232 – Store” you can select which data you wish to transmit. You can then see the measured values 

being scanned into the table on the PC.  

When transmission is complete, you need to acknowledge this by clicking on “Finished?”

 

If you transmit “all” measured values (all measured values or those from one parameter set), the transmission is 

automatically terminated. The button then changes back to “Scan” and the measured-value table is processed:  

 

empty rows are hidden, used rows are shown  

 

the measured values are divided according to parameter set und data record numbers by means of dividing bars 

 

NOK measured values (outside the limits) are stored in red 

 

Print area und page are automatically set up (!) 

 

13.4.4 Measured-value table 

Some of the unused rows may be hidden in the measured-value table. This happens automatically with rows “B” to “L”.. 

Leave the row “M” empty, as it separates the subsequent rows of comments. You can use the rows of comments as you 

will: hide or show them and use them for notes for reading in measured values. They are not altered by the program

, and 

typically do not appear in the printout! 

The print area is automatically set for all measured values. Should you wish to print out some of the data only, change the 

print area beforehand. 

 

Tip: 

 

If you wish to print comments as well, you can enter any character in the first line in the “M” row and then set the row 

width to zero. A comments row is only hidden when it is completely empty.  

 

13.4.5 Statistical analysis  

In the “Statistics” page, you can select 

 according to the parameter set and the data record 

 which measured values 

should be used in the calculation and shown in the diagram.  

You can adjust the head of the page, up to the selection fields, as you wish. Do not alter the section containing the statistics! 

Although the print area is pre-defined on this page, it can still be altered. 

 

Note:

  

 

When both limit values are negative, 

counter-clockwise rotation

 is assumed.  

A measured value that is more negative than the limit value, will then be interpreted as being 

too large!

 Similarly, a 

more positive value is too small! 

 

13.4.6 Measured-value diagram 

The data range for the first row of measured values (and for the limits) is automatically set in the dropdown selection  

fields. Scaling is also set automatically. You can, however, enter values for (fixed) manual scaling.  

You may arrange the diagram (colors, line thickness, ...) as you wish. The best way to do this is to right-click on the desired 

element (context menu). 

 

Note:

    

 

By pointing the mouse exactly over a vertex of the curve, the numerical figures will be shown. 

 

You may insert more self-defined diagram (and table) sheets. 

 

13.4.7 Torque wrench document 

This page is intended as a starting point for your own test logs. It accesses the measured-value table via formulas. This is 

why you can alter this page as you wish. 

 

 

Содержание GMV2-K

Страница 1: ...Subject to change without prior notice OPERATING INSTRUCTIONS G GM MV V2 2 K K Microprocessor Based Power Supply and Analyzing Unit for Torque Transducers...

Страница 2: ......

Страница 3: ...3 7 AUTOMATICALLY TRACKING ZERO POINT DRIFT 11 3 8 PULSE TYPE SCREWDRIVER MODE 11 3 9 STREAMLINING PARAMETER SET ENTRY 11 3 9 1 Defaults 11 3 9 2 Hiding unused functions 11 3 9 3 Correction factor 12...

Страница 4: ...PRINTOUT OF THE PARAMETER SET 22 9 6 SELECTION 23 9 7 CREATE NEW 23 9 8 EDITING 23 9 9 ERASE 26 10 SCREWING TECHNOLOGY 27 10 1 TIME BASED SEQUENCE DIAGRAM 27 10 2 TIMING 27 10 3 ANGLE 28 11 STORING M...

Страница 5: ...11 2 Storing Printing Erasing 34 13 12 MEASURED VALUE PRINTOUT TO THE DIGIMATIC DP 1 HS 34 13 12 1 Introduction 34 13 12 2 Connection and preparation 34 13 12 3 Transmission of limits 35 13 12 4 Print...

Страница 6: ...port for printer Measured data transmission to PC EMC sealed housing 2 Startup 2 1 Important notes If the unit is opened or dismounted within the warranty period the warranty will be rendered null an...

Страница 7: ...Return The four menu keys Key without function Transducer full Torque Angle of rotation or speed Parameter set number Field for error messages Data record Memory number Mode direct function Zeroadj Cl...

Страница 8: ...ETH messtechnik gmbh D 74415 Gschwend P O 16 Nr 162e Operating Instructions GMV2 K revised 09 05 2019 Rev 0 Subject to change without prior notice 8 2 3 Connections overview...

Страница 9: ...n the device time of day software version and the optional functions will be displayed The following abbreviations appear V x xx Software version ax Active input with adjustable input range px Passive...

Страница 10: ...d_range The large measuring range appears in the menu as akt2rng high_range Note This is an optional function and is not available in all devices Select the Standard_range option for transducers with...

Страница 11: ...mode This function is very similar to the peak measuring function additionally a correction factor is available in this mode but angle measurements cannot be taken 3 9 Streamlining parameter set entr...

Страница 12: ...nd when the measuring range is changed The device is subsequently zeroed and the system checks that the settings in the parameter set match the transducer settings 3 12 Power saving function standby M...

Страница 13: ...here are three keys with which a function is immediately executed when pressed Some direct function keys are assigned multiple functions The assigned function depends on the settings selected When no...

Страница 14: ...Delete measured value Menu path Menu MVclear See also sec 11 5 page 29 4 5 Menu Output Measured values and parameter sets can be either displayed on the screen see secs 11 4 and 9 4 or printed out th...

Страница 15: ...an begin Angle limits In contrast to the torque limits angle limits are entered with the Entry editor see Sec 8 3 This means that the angle entry can only be terminated with OK The previous menu level...

Страница 16: ...the menu structure sec 12 page 39 are highlighted in color The enabled level is shown on the bottom left of the screen If the password is programmed in the first level all keys except the On Off key a...

Страница 17: ...eturn key to cancel the setting Notes Date and time of day are briefly flashed on the screen when the unit is switched on which allows you to check them 6 3 Printer Serial interface Menu path Menu Par...

Страница 18: ...e activated The switch off function is not available here An adjustable filter can also be programmed 0 1 to 10 s If switched on the optional angle counting function is permanently enabled It is reset...

Страница 19: ...nology Not only does it allow the largest occurring torque to be detected but also offers numerous functions for assembly automation time based measuring screwdriver control OK NOK assessment with set...

Страница 20: ...ant part of the entry It appears as a flashing bold underline under a number which indicates that this position can now be changed Every time the key is pressed the complete number is increased by the...

Страница 21: ...ecisely adapted for the screwing task at hand It makes sense to assemble all individual parameters for a screwing sequence in one parameter set GMV2 K can save 49 such parameter sets A wide range of s...

Страница 22: ...displayed now with Param or Param The page selection is not affected Parameters from different sets can thus be compared with each other 9 5 Printout of the Parameter Set Menu path Menu Output RS232 P...

Страница 23: ...r set as a template Copy menu A set including set number 0 can be selected for copying with Param and Param After confirmation with OK you should start programming All settings are displayed and the v...

Страница 24: ...orque angle of rotation or speed and power Peak The highest value is stored See Sec 10 for screwings Torque wrench For clockwise rotation only The peak value before yielding point is reached is stored...

Страница 25: ...t is only available when speed was selected beforehand Subsequently the maximum power to be measured has to be set with unit and decimal places Setting range 1 9999 mW to 19999 kW A filter time on the...

Страница 26: ...ata record In this case the text can be input with a barcode scanner The current text appears to the right beside the parameter set text see page 7 This facility is only available when More is selecte...

Страница 27: ...efault setting 0 is selected Otherwise select a long time period Note Without shut off the measurement is not limited by tN and runs on until the peak value is erased The maximum value for angle and t...

Страница 28: ...rewing operation must be repeated a fixed number of times for each workpiece in assembly lines This number can be set as the length of the data record in the parameter set Screwings are the same when...

Страница 29: ...irst for output and confirmed with OK Then use Record and Record to select the next data record and use value and value to select the next value The output is sorted according to data record number It...

Страница 30: ...that have been measured with the first used parameter set Menu Output RS 232 Store OK all Example of a measured value printout DR 1 PAR 1 04 21 99 OK No Md Wkl Time 1 5 95 Nm 09 41 2 6 40 Nm 09 41 3 7...

Страница 31: ...to the device The pin assignment for the socket is shown in Sec 0 page 37 ff 13 3 Digital input You can connect the torque sensors fitted with digital output you receive from ETH with this option The...

Страница 32: ...in the printout The print area is automatically set for all measured values Should you wish to print out some of the data only change the print area beforehand Tip If you wish to print comments as wel...

Страница 33: ...is not a heavy duty relay It is however suited for controlling a programmable controller or a contactor 13 9 NOK output This output signals an NOK screwing under the following conditions 1 At least on...

Страница 34: ...tic DP 1 HS 13 12 1 Introduction Torque measured values can be printed out and statistically evaluated with the Digimatic Mini Processor DP 1 HS printer The statistics functions contain off limit cond...

Страница 35: ...an only process one numeric range Should the position of the decimal point or the sign change when a new parameter set is selected the CL key must be pressed before the first printout If torque and an...

Страница 36: ...ation interval has elapsed Please return the GMV2 K for calibration Warning Calibr memory Error in calibration memory has been eliminated Info No angle Setting angle limits is inhibited without the an...

Страница 37: ...nd socket Pin Signal Pin Signal M Power supply bridge A Memory chip N Reserved Sense C 5V angle supply O Reserved Sense E Angle und chip ground P Power supply bridge G Angle Track A R Signal J Angle T...

Страница 38: ...1 5V active 4V 30V DC 5mA Floating entrances Optocoupler outputs galvanically isolated NO contacts Maximum 150 mA 30V DC Switch off contact pin 19 pin 6 opens when cut off value has been exceeded Rela...

Страница 39: ...Password level 3 contrst CW CCW angle corr F speed power angle passwrd overlde OK OK param param page page param param OK OK param param all OK set set value value param param all OK choose Dec Pnt O...

Отзывы: