Initial settings 

6.1  Language 

Menu path: 

Menu-> Parameter-> Program-> Initial setting-> Language 

 

The unit is fully multilingual. If the language is changed, screen texts, key labels and date format are adapted accordingly. 

The setting becomes effective when the language key is pressed (Caution!) 

German, English, French and Italian have been realized for this software version. 

 

Note: 

Other languages can be realized at customer request. 

 

 

6.2  Time of day and Date 

Menu path: 

Menu-> Parameter-> Setting-> Initial Setting -> Clock 

 

The actual time of day is displayed at the bottom of the screen. A flashing underline (cursor) indicates what can be 

changed. You can change the compete numbers only with the “+” und “-” keys, i.e. you cannot change the units and tens 

separately. The longer you keep the keys pressed, the quicker numbers will change (dynamic). 

Use the “<==” key to move between minute, hour, day, month and year. Don't forget to press the OK key to save the time 

of day! Press the return key to cancel the setting. 

 

Notes: 

 

Date and time of day are briefly flashed on the screen when the unit is switched on – which allows you to check 
them. 

 

6.3  Printer (Serial interface) 

Menu path:  

Menu-> Parameter-> Setting -> Initial setting -> Printer  

 

Procedure:  

First select the desired printer. For "Standard" and “==> PC

 the system prompts you for the baud rate. No baud rate setting 

is required for DP-1 HS. 

 

1.) Selecting the printer:

 

 

"Standard" key for standard printer, (PC transmission with the program “Hyperterminal”) 

 

“===> PC“ key for measured-value transmission in an EXCEL

®

 file (optional) 

The keystroke makes the selection immediately effective and item 2. is selected). 

 
2.) Setting the baud rate: 

Default values 1200 baud to 19200 can be selected in succession with "+" and "-" keys. 

The OK key accepts the selected setting. 

The return key cancels the change and jumps to the "Initial setting" menu. 

 

Notes:  

 

Factory default: baud rate 4800 Bd (suitable for printers supplied by us!), standard printer.  

 

Transmission format: 8 data bits, no parity, 1 stop bit, XON-XOFF, text transmission 

 

See Sec. 15. for pin assignment 

Other formats are available at customer request.  

 

6.4  USB2.0-Interface 

To use the USB2.0 interface, first install the supplied driver software! Only then may the USB port be used. 

 

6.5  Standby (power-saving function) 

See sec. 3.12., page 12. 

 

Содержание GMV2-K

Страница 1: ...Subject to change without prior notice OPERATING INSTRUCTIONS G GM MV V2 2 K K Microprocessor Based Power Supply and Analyzing Unit for Torque Transducers...

Страница 2: ......

Страница 3: ...3 7 AUTOMATICALLY TRACKING ZERO POINT DRIFT 11 3 8 PULSE TYPE SCREWDRIVER MODE 11 3 9 STREAMLINING PARAMETER SET ENTRY 11 3 9 1 Defaults 11 3 9 2 Hiding unused functions 11 3 9 3 Correction factor 12...

Страница 4: ...PRINTOUT OF THE PARAMETER SET 22 9 6 SELECTION 23 9 7 CREATE NEW 23 9 8 EDITING 23 9 9 ERASE 26 10 SCREWING TECHNOLOGY 27 10 1 TIME BASED SEQUENCE DIAGRAM 27 10 2 TIMING 27 10 3 ANGLE 28 11 STORING M...

Страница 5: ...11 2 Storing Printing Erasing 34 13 12 MEASURED VALUE PRINTOUT TO THE DIGIMATIC DP 1 HS 34 13 12 1 Introduction 34 13 12 2 Connection and preparation 34 13 12 3 Transmission of limits 35 13 12 4 Print...

Страница 6: ...port for printer Measured data transmission to PC EMC sealed housing 2 Startup 2 1 Important notes If the unit is opened or dismounted within the warranty period the warranty will be rendered null an...

Страница 7: ...Return The four menu keys Key without function Transducer full Torque Angle of rotation or speed Parameter set number Field for error messages Data record Memory number Mode direct function Zeroadj Cl...

Страница 8: ...ETH messtechnik gmbh D 74415 Gschwend P O 16 Nr 162e Operating Instructions GMV2 K revised 09 05 2019 Rev 0 Subject to change without prior notice 8 2 3 Connections overview...

Страница 9: ...n the device time of day software version and the optional functions will be displayed The following abbreviations appear V x xx Software version ax Active input with adjustable input range px Passive...

Страница 10: ...d_range The large measuring range appears in the menu as akt2rng high_range Note This is an optional function and is not available in all devices Select the Standard_range option for transducers with...

Страница 11: ...mode This function is very similar to the peak measuring function additionally a correction factor is available in this mode but angle measurements cannot be taken 3 9 Streamlining parameter set entr...

Страница 12: ...nd when the measuring range is changed The device is subsequently zeroed and the system checks that the settings in the parameter set match the transducer settings 3 12 Power saving function standby M...

Страница 13: ...here are three keys with which a function is immediately executed when pressed Some direct function keys are assigned multiple functions The assigned function depends on the settings selected When no...

Страница 14: ...Delete measured value Menu path Menu MVclear See also sec 11 5 page 29 4 5 Menu Output Measured values and parameter sets can be either displayed on the screen see secs 11 4 and 9 4 or printed out th...

Страница 15: ...an begin Angle limits In contrast to the torque limits angle limits are entered with the Entry editor see Sec 8 3 This means that the angle entry can only be terminated with OK The previous menu level...

Страница 16: ...the menu structure sec 12 page 39 are highlighted in color The enabled level is shown on the bottom left of the screen If the password is programmed in the first level all keys except the On Off key a...

Страница 17: ...eturn key to cancel the setting Notes Date and time of day are briefly flashed on the screen when the unit is switched on which allows you to check them 6 3 Printer Serial interface Menu path Menu Par...

Страница 18: ...e activated The switch off function is not available here An adjustable filter can also be programmed 0 1 to 10 s If switched on the optional angle counting function is permanently enabled It is reset...

Страница 19: ...nology Not only does it allow the largest occurring torque to be detected but also offers numerous functions for assembly automation time based measuring screwdriver control OK NOK assessment with set...

Страница 20: ...ant part of the entry It appears as a flashing bold underline under a number which indicates that this position can now be changed Every time the key is pressed the complete number is increased by the...

Страница 21: ...ecisely adapted for the screwing task at hand It makes sense to assemble all individual parameters for a screwing sequence in one parameter set GMV2 K can save 49 such parameter sets A wide range of s...

Страница 22: ...displayed now with Param or Param The page selection is not affected Parameters from different sets can thus be compared with each other 9 5 Printout of the Parameter Set Menu path Menu Output RS232 P...

Страница 23: ...r set as a template Copy menu A set including set number 0 can be selected for copying with Param and Param After confirmation with OK you should start programming All settings are displayed and the v...

Страница 24: ...orque angle of rotation or speed and power Peak The highest value is stored See Sec 10 for screwings Torque wrench For clockwise rotation only The peak value before yielding point is reached is stored...

Страница 25: ...t is only available when speed was selected beforehand Subsequently the maximum power to be measured has to be set with unit and decimal places Setting range 1 9999 mW to 19999 kW A filter time on the...

Страница 26: ...ata record In this case the text can be input with a barcode scanner The current text appears to the right beside the parameter set text see page 7 This facility is only available when More is selecte...

Страница 27: ...efault setting 0 is selected Otherwise select a long time period Note Without shut off the measurement is not limited by tN and runs on until the peak value is erased The maximum value for angle and t...

Страница 28: ...rewing operation must be repeated a fixed number of times for each workpiece in assembly lines This number can be set as the length of the data record in the parameter set Screwings are the same when...

Страница 29: ...irst for output and confirmed with OK Then use Record and Record to select the next data record and use value and value to select the next value The output is sorted according to data record number It...

Страница 30: ...that have been measured with the first used parameter set Menu Output RS 232 Store OK all Example of a measured value printout DR 1 PAR 1 04 21 99 OK No Md Wkl Time 1 5 95 Nm 09 41 2 6 40 Nm 09 41 3 7...

Страница 31: ...to the device The pin assignment for the socket is shown in Sec 0 page 37 ff 13 3 Digital input You can connect the torque sensors fitted with digital output you receive from ETH with this option The...

Страница 32: ...in the printout The print area is automatically set for all measured values Should you wish to print out some of the data only change the print area beforehand Tip If you wish to print comments as wel...

Страница 33: ...is not a heavy duty relay It is however suited for controlling a programmable controller or a contactor 13 9 NOK output This output signals an NOK screwing under the following conditions 1 At least on...

Страница 34: ...tic DP 1 HS 13 12 1 Introduction Torque measured values can be printed out and statistically evaluated with the Digimatic Mini Processor DP 1 HS printer The statistics functions contain off limit cond...

Страница 35: ...an only process one numeric range Should the position of the decimal point or the sign change when a new parameter set is selected the CL key must be pressed before the first printout If torque and an...

Страница 36: ...ation interval has elapsed Please return the GMV2 K for calibration Warning Calibr memory Error in calibration memory has been eliminated Info No angle Setting angle limits is inhibited without the an...

Страница 37: ...nd socket Pin Signal Pin Signal M Power supply bridge A Memory chip N Reserved Sense C 5V angle supply O Reserved Sense E Angle und chip ground P Power supply bridge G Angle Track A R Signal J Angle T...

Страница 38: ...1 5V active 4V 30V DC 5mA Floating entrances Optocoupler outputs galvanically isolated NO contacts Maximum 150 mA 30V DC Switch off contact pin 19 pin 6 opens when cut off value has been exceeded Rela...

Страница 39: ...Password level 3 contrst CW CCW angle corr F speed power angle passwrd overlde OK OK param param page page param param OK OK param param all OK set set value value param param all OK choose Dec Pnt O...

Отзывы: