12 Printing out the stored measured values
Menu path:
Menu-> Output-> RS 232-> Store
Measured values are always printed out here in sets and are ordered firstly according to the used parameter set number and
secondly according to the data record number.
You can choose to print out the entire measured-value storage in the first menu "Param + / Param - / all / OK". Use "Param
+" and "Param -" to choose a particular parameter set. Observe the "PAR:" display. "OK" terminates this selection and
branches to the next menu. You can decide now in the menu " / Record - / all / OK" whether you want to print out
all data records in the selected parameter set or only a particular one.
The "all" key starts the printout immediately, it must not be confirmed with "OK"!
Notes:
•
An individual measurement can be printed out with the direct function key "Output", when "No storing" is set.
•
Some limitations apply to DP-1 HS (optional) (see sec. 13.12):
Examples
•
Print out all stored measured values:
Menu -> Output -> RS 232 -> Store -> all.
•
Print out all data records that have been measured with the first used parameter set:
Menu -> Output -> RS 232 -> Store -> OK -> all.
Example of a measured-value printout:
========================
DR: 1 PAR: 1 04/21/99
OK No Md/Wkl Time
1 5.95 Nm 09:41
2 6.40 Nm 09:41
3 7.65 Nm 09:41
4 8.73 Nm 09:41
========================
DR: 1 PAR: 2 12/24/02
OK No Print Time
N 1 56.5 Bar 09:33
O 2 101.5 Bar 09:33
O 3 125.3 Bar 09:34
O 4 131.4 Bar 09:34
O 5 133.9 Bar 09:34
N 6 154.8 Bar 09:34
========================
DR: 1 PAR: 6 04/21/99
OK No Md/Wkl Time
1 -9.39 ftlb 09:39
O -145 degrees
2 -9.75 ftlb 09:39
O -179 degrees
========================
PAR: TESTTEXT P5
------------------------
DR: 1 PAR: 5 10/22/02
OK No Md/Wkl Time
1 133 Nm 11:00
833 rev/min
11.601 kW
2 274 Nm 11:00
333 rev/min
9.554 kW
3 900 Nm 11:01
100 rev/min
9.424 kW
========================
PAR: MOT BLOCK WMB
------------------------
DR: 1 PAR: 4 01/06/03
OK No Force Time
I 1 19.58 N 14:36
I 2 19.64 N 14:36
------------------------
Op no: 1001
........................
========================
PAR: WHEELRIM9112
DR: ID3000197028
------------------------
DR: 1 PAR: 6 01/06/03
OK No Md/Wkl Time
O 1 76.75 Nm 14:38
O 2 76.11 Nm 14:41
O 3 75.64 Nm 14:48
N 4 74.25 Nm 14:51
------------------------
Op no: 12
........................
========================
PAR: WHEELRIM9112
DR: ID3000197111
------------------------
DR: 1 PAR: 6 01/06/03
OK No Md/Wkl Time
O 1 77.75 Nm 14:38
O 2 76.43 Nm 14:41
O 3 78.02 Nm 14:48
O 4 75.05 Nm 14:51
------------------------
Op no: 12
........................
Notes:
•
All clearances between
words are blanks
•
The end-of-line comprises
"CR" and "LF"
•
The line length is less than
32 characters
•
Blank lines comprise
several "CR"s / "LF"s
•
The printout is terminated
with at least one blank line
•
See section 15 for
transmission format and
protocol