Floor Mounting
GU100 can be installed standing on combustible floor surface, or on a water heater stand.
Be sure to use a suitable draining pan under the unit if leakage of the tank or connections will resuit in damage to
the area adjacent to the appliance.
Place unit directly on an even surface. Factory installed rubber feet can be adjusted if the surface is slightly uneven.
Secure the unit to the wall with included wall mount bracket. Be sure to install the wall mount bracket to the wall studs.
□
□
Standing Installation
Floor Standing
Earthquake Proofing
Factory Installed Rubber Feet
If local codes require the water heater to be raised 18" above floor, installing GU100 on the optional Eternal
Water Heater Stand (P/N 314080136) will satisfy code. In conjunction, the unit on stand raises the FVIR
compliant igniter and burner at least 18" off the floor. Alternatively, raising the unit at least 6" off the floor will also
satisfy code.