SealerAtor User Manual
Choose a Specific Test
Note:
See
to select the profile of the fixture you intend
to test.
Navigate: Main Menu
→
Test
→
Manual Test
Choose to perform either the vacuum test or the pressure test.
Menu Item Values
Description
Vacuum
•
Target Value
•
Min. Value
•
Time Hold
•
ON
•
OFF
Perform the vacuum test.
To begin the test, navigate to OFF and press the right
navigation button.
To stop the test before it is complete, press the left navigation
button.
The Target Value, Min. Value, and Time Hold value shown in
the Vacuum window are predefined for your ETC fixture. ETC
recommends that you do not change the values.
Pressure
•
Target Value
•
Min. Value
•
Time Hold
•
ON
•
OFF
Perform the pressure test.
To begin the test, navigate to OFF and press the right
navigation button.
To stop the test before it is complete, press the left navigation
button.
The Target Value, Min. Value, and Time Hold value shown in
the Pressure window are predefined for your ETC fixture. ETC
recommends that you do not change the values.
Note:
•
The test results for Manual tests that are run from the onboard user interface are
not saved.
•
If the test fails, contact ETC Technical Support for assistance.
Test the SealerAtor
Navigate: Main Menu
→
Test
→
Self-Test
Do not use the Self-Test option unless directed to do so by ETC Technical Services. Contact
Technical Services for specific instructions. Refer to
Help from Technical Services on page 2
for
contact information.