ES5095.1 Break-Out-Panel (80-CH) - User’s Guide
8
Introduction
ETAS
• Hardware interface for ECUs in a hardware-in-the-loop test system
The ES5095.1 is not intended for use:
• Within a vehicle on the road
• As part of a life support system
• In applications where misuse can lead to injuries or damages
• In environments in which conditions prevail that fall outside the specified
ranges: See "Ambient Conditions" on page 22
• With signal conditioning that falls outside the specified ranges: See "Tech-
nical Data, Standards and Order Data" on page 21
Requirements for Operation
The following requirements are necessary for safe operation:
• Use the product only according to the specifications in the corresponding
User's Guide. With any deviating operation, the product safety is no lon-
ger ensured.
• Observe the regulations applicable at the operating location concerning
electrical safety as well as the laws and regulations concerning work
safety!
• Observe the requirements for the ambient conditions.
• Do not use the product in a wet or damp environment.
• Do not use the product in potentially explosive atmospheres.
• Keep the surfaces of the product clean and dry.
Requirements for the Technical State of the Product
The product is designed in accordance with state-of-the-art technology and rec-
ognized safety rules. The product may be operated only in a technically flawless
condition and according to the intended purpose and with regard to safety and
dangers as stated in the respective product documentation. If the product is not
used according to its intended purpose, the protection of the product may be
impaired.
Electrical Safety and Power Supply
• Observe the regulations applicable at the operating location concerning
electrical safety, as well as the laws and regulations regarding safety at
work.
• Connect only current circuits with safety extra-low voltage in accordance
with EN 61140 (degree of protection III) to the connections of the module.
• Ensure that the connection and setting values are adhered to (see the
information in the chapter "Technical Data").
• Do not apply any voltages to the connections of the module that do not
correspond to the specifications of the respective connection.
Содержание ES5095.1
Страница 1: ...ES5095 1 Break Out Panel 80 CH User s Guide...
Страница 4: ...ES5095 1 Break Out Panel 80 CH User s Guide 4 Contents ETAS 5 ETAS Contact Addresses 23 Index 25...
Страница 12: ...ES5095 1 Break Out Panel 80 CH User s Guide 12 Introduction ETAS...
Страница 17: ...ES5095 1 Break Out Panel 80 CH User s Guide 17 ETAS Connections and Connectors Fig 3 1 Pin Assignment Rear...
Страница 24: ...ES5095 1 Break Out Panel 80 CH User s Guide 24 ETAS Contact Addresses ETAS...