4. Defective wiring or connections
2. Conduct a test with a jumper wire and
repair as required
5. Defective Valve
3. Contact service technician
I.
Soot deposits
1. Air inlet blocked or restricted
1. Clean air inlets
2. Vent system is restricted or
inadequate
2. Confirm venting & termination are those
which are approved with the appliance
3. Logs are sooting up
3. Check manual for correct log placement
V.
Flame burns blue and lifts
off burner
1. Insufficient combustion air being
supplied
1. Ensure that no foreign material blocks air
inlets. Ensure the vent is adequate
2. Manifold pressure set too high
2. Check manifold pressure
3. Vent system restricted
3. Check vent system
VI. Main flame does not burn
properly
1. Incorrect vent or termination
used.
1. Confirm venting & termination are those
which are approved with the appliance
VII. Flames impinge on firebox
top
1. Vent system is restricted or
inadequate
1. Correct flue as required
2. Manifold pressure too high
2. Check manifold pressure as required