![ESSEDUE 220 AF Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/essedue/220-af/220-af_owners-and-maintenance-manual_2428306019.webp)
CE Domestic Slicer
ESSEDUE
OWNER'S AND MAINTENANCE MANUAL – Original Manual
19
8 DEMOLITION AND DISPOSAL
The WEEE symbol shown below indicates that the slicer, at the end of its useful life, must be
collected separately from other waste.
The user must adopt special precautions regarding the decommissioning of environmentally
harmful materials such as plastic parts, electrical connections, and lubricants, in compliance to
European, national regulations and local regulations.
User must dispose the slicer, at the end of its useful life, to an appropriate recycling centers for
electronic and electrical waste.
Improper disposal of the product by the User implies application of administrative penalties in
compliace to local regulation.
9 TRUBLESHOOTING GUIDE
9.1
Trubleshooting
Hereinafter User will find the most common problems that may occur when using the slicer, the
causes that probably generated them and solution to solve them. If the problem persists, contact the
“Service Centre”.
SYMPTOM
CAUSE
SOLUTION
After pressing on switch,
machine will not start
Slicer not plugged in
Ensure that the slicer is plugged in,
power supply lasts and check safety
devices.
The machine vibrates,
overheats, smells bad.
Power supply does not meet
specification on data label.
Switch off the machine and check that
power supply meet specification on
data label.
Poor cut quality
Non sharpened blade
Sharpen the blade.
Worn blade
Call service to replace the blade.
Blade diameter reduced to
less than 10 mm from its
original dimension
Call service to replace the blade.
Metal rubbing knife
Knife cover
Tighten cover release knob.
Food chute
Tighten food chute release knob.
Food chute
Reinstall food chute.
Slicer table
Call for service.
Blade hard to sharpen, non
normal sharpening.
Dirty sharpener stones
Clean sharpener stones with a brush
and warm. Allow stones to air dry.
Worn sharpener stones
Replace sharpener stones.
Dirty blade
Ensure slicer table is completely
closed, then clean the blade with a
clean cloth soaked in a mild detergent
and warm water solution.
Blade diameter reduced to
less than 10 mm from its
original dimension
Call service to replace the blade.
Food chute hard to push
No lubrification
Clean food chute slide rod, then
lubrificate with vaseline oil.
In the event that the proposed solutions do not solve the problems, please contact a “Service
Centre”.