7. APPENDIX
14
Rev. 20.01.14
ASSEMBLY MANUAL FOR STEEL ROOFS
Frame height
End clamp
Screw length
29mm
CFA
55 mm
30mm
CFA
55 mm
31mm
CFB
55 mm
32 mm
CFB
55 mm
33 mm
CFA
60 mm
34 mm
CFA
60 mm
35 mm
CFB
60 mm
36 mm
CFB
63 mm
37 mm
CFA
63 mm
38 mm
CFA
63 mm
39 mm
CFB
63 mm
40 mm
CFB
63 mm
41 mm
CFA
70 mm
42 mm
CFA
70 mm
43 mm
CFB
70 mm
44 mm
CFB
70 mm
45 mm
CFA
70 mm
46 mm
CFA
70 mm
47 mm
CFB
75 mm
48 mm
CFB
75 mm
49 mm
CFA
75 mm
50 mm
CFA
75 mm
51 mm
CFB
75 mm
52 mm
CFB
75 mm
Ensure that the battery screwdriver (with caplet S8) is set to a slip coupling with a maximum coupling of 3N/m so the screw
does not overturn. As soon as the rubber on the screw distorts the screw is tight and the roof is watertight.
Mounting of self-tapping plate screw 6.0x25mm
too loose
good !
too tight
skewed