26
chronostat the same command as the one made with the button or
if the telephone interface is reset. In such a case the status set by
means of the control button will not be changed and the chronostat
will be ready to receive a new command.
IMPORTANT
If an Off command is sent to the chronostat via the telephone
interface (contact open), it is a good idea to check that the
command has been executed by the chronostat by carrying out
the following realignment procedure:
1. Using the functions of the telephone interface, check that the
contact is open, sending an Off command if necessary.
2. Send a command to the telephone interface to close the
contact (the chronostat will turn on).
3. Using the functions of the telephone interface, check that the
contact is closed.
4. Send a command to the telephone interface to open the
contact (the chronostat will turn off).
During this sequence no commands should be input with
the control buttons as they have priority over the interface
commands.
HOW TO INSERT / REPLACE BATTERIES
The battery charge status is constantly displayed by means of the
‘
‘ symbol.
The battery charge is at a maximum if all three level indicators are
lit inside the symbol.
Instead the batteries are depleted and must be replaced when the
symbol appears completely empty ‘
‘.
The ‘
‘ symbol flashes in case the batteries are too depleted to
allow a radio transmission
To replace the batteries proceed as follows:
1.
Open the flap of the battery compartment (Fig. 1).
2.
Remove the batteries, prying them out with the aid of a tool if
necessary.
3.
Insert the new batteries, which must be alkaline 1.5V type AA.
4.
Only if the chronostat does not respond correctly carry out a reset
operation by inserting a pointed object through the hole provided
(
N
in Fig. 1);
DO NOT USE NEEDLES OR TOOLS THAT COULD
IRREPARABLy DAMAGE THE CHRONOSTAT
.
5.
Check that the time is set correctly; adjust the setting if necessary.
- ENGLISH -