29
switching On or Off. Alternatively pressing ‘
OK
’ button when in the
main screen, the user can force an update.
For the same reason, at the expiry of the time schedule’s half hour,
there will not be an immediate switch of the output, it will be
necessary to wait up to 3 minutes in the worst case to see the new
output state updated.
BACKLIGHTING
The display backlight turns on whenever and button is pressed. It turns
off automatically 20 seconds after the last pressing of a button.
USER MENU SETTINGS
The user menu allows the user to set some configuration parameters
of the chonostat.
To enter in the menu press the ‘
P
‘ button, the display will show the
‘
P
’ icon (bottom right) and the text ‘
PrOG
‘. Pressing repeatedly
the ‘
P
‘ button the following user parameters will be scrolled:
‘
PrOG
’
Schedule Programming
‘
tESt
’ Test mode activation
‘
AFr
’
Antifreeze Setting
‘
MOrE
’ Access to the advanced parameters menu
Press the ‘
OK
’ button to display the value of the parameter. To
modify the selected parameter use the arrow buttons ‘
’ and ‘
’. Press the ‘
OK
’ button again to save and exit or press ‘ ’ to exit
without saving the changes.
In any case the chonostat exits automatically after 20 seconds of
no buttons activity.
‘
PrOG
‘: SCHEDULE PROGRAMMING
Normally the chonostat displays the programmed schedule for the
current day. The current day of the week is displayed on the left with
a box around the corresponding day’s number, 1 Monday .. 7 Sunday.
The dashes line in the top of the display shows the time schedule
from 0.00 to 12.00 AM with half an hour steps, while the dashes line
in the bottom shows the time schedule from 12.00 to 24.00 PM.
The dashes show the operating mode of the chonostat, Comfort,
Economy, Off/Antifreeze for every half an hour of the day as shown
in the following:
- ENGLISH -