-- 68 --
bu12d04a
9.5
Error Log
MAIN MENU
AUXILIARY FUNCTIONS
ERROR LOG
All errors which occur during the use of the welding equipment are documented as
error messages in the error log. Up to 99 error messages can be saved, If the error
log is full, i.e. if 99 error messages have been saved, the oldest message is
automatically deleted when the next error occurs.
12
"
Date
Time
Unit
Error
970422
15:52.24
C--BOX
18
Warning state in bus communication
970422
16:54.04
C--BOX
12
Lost the contact with the current source
970423
09:14.33
PSOURCE
6
High temperature
DELETE
DELETE
ALL
VIEW
TOTAL
QUIT
9.5.1
Delete Error Message
Each button provides 2 possibilities for deleting the error messages.
S
Delete
marked
messages
S
Delete
all
messages
9.5.2
Summary of Errors
By pressing the VIEW TOTAL button, you can receive a display of the number of
registered error messages in the error log. Also shown here are the date and time of
the oldest and the last registered error messages.
ERROR LOG -- TOTAL LISTING
TOTAL ERROR MESSAGES: 12
OLDEST ERROR
970417. 11:09.11
LATEST ERROR
970429. 13:04.45
QUIT