-- 23 --
bu12d04a
START DATA. SYNERGIC MODE
Position the cursor
on the line marked
WIRE SPEED. Set
it to 98 in/min (2.5
m/min).
GASPREFLOW:
0.8 s
CREEPSTART:
YES
HOTSTART:
YES
HOT START TIME:
1.0 s
WIRE SPEED
:
98 in/min (2.5 m/min)
CRATR
FILL
HOT
D
START
4--
STROKE
QUIT
All the start settings have now been made.
START DATA. SYNERGIC MODE
Return to the
settings menu by
pressing QUIT.
GASPREFLOW:
0.8 s
CREEPSTART:
YES
HOTSTART:
YES
HOT START TIME:
1.0 s
WIRE SPEED:
98 in/min (2.5 m/min)
CRATR
FILL
HOT
D
START
4--
STROKE
QUIT
2.8.4
Stop Data Settings
The stop data menu is used to make the settings that affect the stop sequence
during MIG welding.
We will enter the following stop data:
S
CRATER FILL = YES
S
CRATER FILL TIME = 1.5 s
S
FINAL WIRE FEED SPEED = 118 in/min (3.0 m/min).
S
BURNBACK TIME =0.11 s
S
GAS POST--FLOW = 2.0 s
Make sure that the settings menu is displayed.
WELD DATA SETTING
Position the cursor
on the line STOP
DATA and press
ENTER.
VOLTAGE:
# 29.0 (+0.0) V
WIRE SPEED:
*
393 in/min
INDUCTANCE:
80 %
SYNERGIC MODE
ON
START DATA . . .
STOP DATA . . .
CRATR
FILL
HOT
D
START
4--
STROKE
QUIT
ENTER