-- 37 --
bu12d04a
WELD DATA SETTING
Set SLOPE DOWN
TIME to 1.4 s by
stepping with the
lower plus/minus
button.
CURRENT:
200 A
SLOPE UP TIME:
# 2.0 s
SLOPE DOWN TIME:
*
1.4 s
GASPREFLOW:
2.5 s
GASPOSTFLOW:
3.3 s
GAS
PURGE
4
STROKE
QUIT
Gas Pre-- and Post--Flow
The gas pre-- and post--flow parameters are connected to specific plus/minus
buttons in the same way as for the above ramp parameters. The upper plus/minus
button applies during setting of gas pre--flow and the lower button is used during
setting of gas post--flow.
WELD DATA SETTING
Place the cursor on the
row for GAS
PRE--FLOW and GAS
POST--FLOW.
Set GAS PRE--FLOW
to 3 s. by stepping with
the upper plus/minus
button.
CURRENT:
200 A
SLOPE UP TIME:
2.0 s
SLOPE DOWN TIME:
1.4 s
GASPREFLOW:
# 3.0 s
GASPOSTFLOW:
*
3.3 s
GAS
PURGE
4
STROKE
QUIT
WELD DATA SETTING
Set GAS
POST--FLOW to
5.0 s. by stepping
with the lower
plus/minus button.
CURRENT:
200 A
SLOPE UP:
2.0 s
SLOPE DOWN:
1.4 s
GASPREFLOW:
# 3.0
GASPOSTFLOW:
*
5.0
GAS
PURGE
4
STROKE
QUIT
We have now completed the settings for TIG welding.