Use and maintenance manual
Automatic die cutter
Model: DC-200
____________________________________________________________________________________________________________________
P a g . 7
We shall check that the regulator pressure is between 2 and 6 bar.
Safety systems and messages.
This die cutter has been equipped with the following safety systems:
1- EMERGENCY STOP
This system allows an emergency stop to be performed at any time using the two push
buttons located at both ends of the bench.
MESSAGE: EMERGENCY BUTTON PRESSED
To deactivate it, we must unlock the push button and then press RESET to return the head to
the starting point.
CLAMP OPEN
This device does not allow engagement of the cutting head if the bar holding the belt is not
lowered.
MESSAGE: CLAMP OPEN
To deactivate it, all we need is to lower the bar and press START.
3- DOOR OPEN
This device detects that the rear door of the blade head is open.
MESSAGE: COVER OPEN