LBI-39224
3-62
Asynchronous (async) ports, up to 5, are assigned first and then
synchronous (sync) ports are assigned.
Save And Send NIM T1/E1 Configurations
Any
T1/E1 Digital Site Configuration
dialog box or
T1/E1 Interface Card Auto-configuration
dialog box changes must
be sent before the changes will come into effect at the CEC/IMC. This
reprograms the NIM Controller Boards and T1/E1 Interface Cards. The
new configurations must be saved before sent to the CEC/IMC, if
sending is attempted before saving a "Site data must be saved to disk
prior to send" message box will appear. Save and send may be
performed either from the
T1/E1 Interface Card Auto-configuration
dialog box only, or from the
Site Channel Configuration List
dialog
box, similar to Audio Board save and send.
T1/E1 Interface Card Auto-configuration
dialog box
Save
Choose the
Save
button to perform an immediate save of the currently
selected site-type interface module's channel configuration. The
channel configuration is saved on the CEC/IMC Manager's hard disk
drive. Any previous channel configuration for the "site," if present, is
erased and replaced with the current channel configuration. If the
CEC/IMC Manager is running remotely or as a part of the EDACS
Network Manager, this configuration is saved on the CEC/IMC
Manager server, typically local to the CEC/IMC; it is not saved at the
remote location.
Send
Choose the
Send
button to send the T1/E1 site channel configuration
data to the respective interface module. This procedure must be
performed before the interface module will operate with the new
configuration. Only configured and configured-and-active (C and C/A
prefixes) configurations may be sent. All configuration data is sent to
the MOM Controller Board; the T1/E1 configuration is sent directly out
from there to the respective interface module Controller Board. A
"Send to Site Successful" message will be received to confirm that the
data was received by the interface module Controller Board. Bus Slot
configuration data is based on the channel assignment in the Set Site
Channel Disbursement field (one bus slot per channel assigned) and is
compared to the current configuration at the CEC/IMC Manager; if
different, it is sent to the MOM Controller Board (if not, no further
Содержание LBI-39224
Страница 1: ...LBI 39224 ericssonz Operations Guide EDACS CEC IMC MANAGER Version 5 0 for Windows NT...
Страница 2: ......
Страница 6: ...LBI 39224 vi This page intentionally blank...
Страница 16: ...LBI 39224 xvi This page intentionally blank...
Страница 22: ...LBI 39224 1 6 This page intentionally blank...
Страница 30: ...LBI 39224 2 8 This page intentionally blank...
Страница 238: ...LBI 39224 3 208 This page intentionally blank...
Страница 268: ...LBI 39224 4 30 This page intentionally blank...
Страница 304: ...LBI 39224 D 2 This page intentionally blank...
Страница 312: ...LBI 39224 E 8 This page intentionally blank...
Страница 324: ...LBI 39224 G 12 This page intentionally blank...