reprograms the CCI and VMIM Controller Boards.  If after making
changes, a save is performed but a send is not, the actual CEC/IMC
conventional channel operation will differ from the displayed settings
upon re-entering the 

Conventional Channel Configuration

 dialog

box.

Save

Choose the 

Save

 button to save the currently selected local

conventional channel's configuration to the CEC/IMC Manager's hard
disk drive.  If during the current edit session, any other channels'
configurations have changed, these channels are not saved.  A remote
conventional channel's configuration cannot be saved.  All of the
channel's high-level and low-level configurations are saved at the
CEC/IMC Manager.

Send

Choose the 

Send

 button to send the currently selected conventional

channel's high-level and low-level configuration to the CEC/IMC.  A

Send

 also automatically saves the currently selected channel's

configuration to the CEC/IMC Manager.  Configuration data is
distributed to the channel's VMIM/CIA set as required.  All settings
affect (are programmed/stored within) the CCI Controller Board and
the CI Boards within the respective CIA rack.  In addition, Causeway
settings also affect the respective VMIM Controller Board.

State Table

Choose the 

State Table

 button to display either the

Tone Controlled Station State Table Mapping

 dialog box or the

DC Controlled Station State Table Mapping

 dialog box.  The

control signaling type selected earlier (above) determines which dialog
box will be displayed when 

State Table

 is chosen.  Tone Control/DC

Control configuration on the currently selected conventional channel is
provided by these dialog boxes.  If any changes have been made and
not saved, you will be prompted (

Write Changes to Disk?

) to save

and display one of the above state table dialog boxes (

Yes

), display one

of the above state table dialog boxes without saving (

No

), or cancel the

State Table

 command (

Cancel

) and remain in the

Conventional Channel Configuration

 dialog box.  See Tone

Control/DC Control Configuration ("State Tables," Etc.) on page 3-166
for additional details.

Содержание LBI-39224

Страница 1: ...LBI 39224 ericssonz Operations Guide EDACS CEC IMC MANAGER Version 5 0 for Windows NT...

Страница 2: ......

Страница 3: ...oduce or copy the PRODUCT make or permit any change or modification in whole or in part in its original or any other language or permit anyone else to do so for any purpose whatsoever except as necess...

Страница 4: ...dows and Windows NT are either registered trademarks or trademarks of Microsoft Corporation Pentium is a registered trademark of Intel Corporation NETCLOCK 2 is a trademark of Spectracom Corporation T...

Страница 5: ...or improvements to programs and or equipment may be made by Ericsson Inc at any time and without notice Such changes will be incorporated into new editions of this manual No part of this manual may be...

Страница 6: ...LBI 39224 vi This page intentionally blank...

Страница 7: ...AM 3 1 3 1 1 Default User Account 3 1 3 2 USER ACCOUNT CONFIGURATION 3 3 3 2 1 Set Up Accounts 3 5 3 2 2 Modify Accounts 3 7 3 3 CEC IMC MANAGER FONT SELECTION 3 8 3 4 INITIAL CEC IMC MANAGER AND MOM...

Страница 8: ...ls 3 145 3 14 2 Causeway Patch Simulselect 3 152 3 14 3 Conventional Channel Configuration 3 155 3 15 LOGGING RECORDER CONFIGURATION 3 174 3 15 1 LRIM Module Configuration 3 175 3 15 2 Save and Send L...

Страница 9: ...1 5 1 OFF LINE DIAGNOSTIC FUNCTIONS 5 1 5 1 1 CALLS EXE 5 1 5 1 2 GSCMON EXE 5 4 6 CHAPTER 6 NETCLOCK 2 INTERFACE OPTION 4 1 6 1 OVERVIEW 6 1 6 2 NETCLOCK INSTALLATION 6 2 6 2 1 Hardware Installation...

Страница 10: ...Box MIM Shown 3 24 Figure 14 Audio Interface Type Dialog Box Audio Board selected 3 27 Figure 15 Audio Interface Type Dialog Box T1 E1 Interface Card selected 3 28 Figure 16 Site Audio Channel Config...

Страница 11: ...ent Configuration Dialog Box 3 180 Figure 41 Activate TDM Bus Slots 3 188 Figure 42 Unit Group Location and Unit Logout Dialog Box 3 189 Figure 43 ProSound Site Adjacency Configuration Dialog Box 3 20...

Страница 12: ...3 119 Table 5 Switch Assignment Number to Conventional Channel Allocation Mapping for StarGate Networks Max Conv Channels per CEC IMC 64 3 147 Table 6 Switch Assignment Number to Conventional Channel...

Страница 13: ...an extensive on line Help system when you set up CEC IMC Manager Version 5 0 for Windows NT The following list outlines the various pieces of the CEC IMC Manager for Windows NT documentation The EDACS...

Страница 14: ...rent time or a description of the currently selected menu option Selecting single clicking an item usually means marking it with the selection cursor which can then appear as a highlight a dotted rect...

Страница 15: ...lly exclusive options you can select only one option at a time if you already have one option selected your current selection replaces it the names of unavailable options appear dimmed Option A Option...

Страница 16: ...LBI 39224 xvi This page intentionally blank...

Страница 17: ...ce with the configuration procedures in EDACS Network Management Installation and Technical Reference Manual LBI 39171 Throughout this program there will be references to configuration data saved to s...

Страница 18: ...Network Manager platforms CEC IMC Configuration Trunked and Console Channels Adjust audio levels and other related parameters for each site type console and EDACS Data Gateway EDG interface Conventio...

Страница 19: ...ile Transfer Transfer unit group and site databases from the System Manager to the CEC IMC Manager Distribute System Manager database information stored at the CEC IMC Manager to CEC IMC interface mod...

Страница 20: ...MC system 1 2 2 System Monitoring View Node Data View status and errors on an interface module by interface module basis Feature Data View currently licensed features and capacities Diagnostics View i...

Страница 21: ...ller Board then periodically dumps its data log buffer to the CEC IMC Manager through their serial link The CEC IMC Manager writes this data to its hard disk where it can be extracted and viewed eithe...

Страница 22: ...LBI 39224 1 6 This page intentionally blank...

Страница 23: ...operate the CEC IMC Manager V5 0x A An IBM Compatible PC with a 75 MHz Pentium microprocessor or better running Microsoft Windows NT V3 51 or better with the following minimum configuration Service Pa...

Страница 24: ...skettes away from magnetic fields as found in electronic equipment If you follow these simple guidelines you will receive long service from your diskettes 2 4 MAKING BACKUPS This software is provided...

Страница 25: ...l CEC IMC Manager machine default MOM_NT Multiple CEC IMC Managers on LAN If ANY other machine name is used other than the default machine name default MOM_NT the following action must be performed De...

Страница 26: ...ion to the just installed Windows NT CEC IMC Manager This should be the second time MIGRATE BAT was run since the original DOS CEC IMC Manager configuration was saved using this utility on the DOS CEC...

Страница 27: ...the Configured Active Sites list box c Choose the Modify button d For each CTIM push the CEC IMC to Disk button e Verify the Slots match in the Upper and Lower list boxes for ALL channels 9 The TDM B...

Страница 28: ...ust be read from the CEC IMC in the DVIM Audio Configuration screens a Select menu option Configure System CEC IMC Configuration DVIM b Select ALL DVIMs that are displayed in the Configured Active DVI...

Страница 29: ...Refer to the operating manuals of each device for correct installation procedures Also see CEC IMC Digital Audio Switch Installation Set Up and Troubleshooting LBI 38938 for interconnection details U...

Страница 30: ...LBI 39224 2 8 This page intentionally blank...

Страница 31: ...m software loading and system hookups have been completed The program software is installed at the factory for new systems however refer to Section 2 7 SYSTEM HOOK UP of the previous chapter if system...

Страница 32: ...ser name and password before execution of the program will continue The default user name is MOMUSER and the default password is GUEST These log in defaults are provided in the PASSWORD DAT file that...

Страница 33: ...twelve accounts unless it is deleted These log in defaults are provided in the PASSWORD DAT file that is part of the CEC IMC Manager installation To prevent unauthorized access deleting this default...

Страница 34: ...to the various access levels From the CEC IMC Manager menu bar select Configure System CEC IMC Manager Configuration to display the CEC IMC Manager Configuration menu shown in Figure 3 Figure 3 CEC I...

Страница 35: ...new user account Adding a new user account involves adding the new user name selecting a password and establishing the access level This is done in the Add Modify Delete Users dialog box Figure 5 by s...

Страница 36: ...tem Administrator Console Administrator General Maintenance and User System Administrator this level has access to all system functions Console Administrator this level has access to system monitoring...

Страница 37: ...e Save button to save any changes to user account configurations to the CEC IMC Manager hard disk Delete Choose the Delete button to delete the selected user account Close Choose the Close button to e...

Страница 38: ...ccess Level System administrators can use this option to change the access level of a given user account This option is performed from the Add Modify Delete Users dialog box Modify User Select the acc...

Страница 39: ...e CEC IMC Manager main menu bar select Configure System CEC IMC Manager Configuration Font Selection to display the Font dialog box Figure 6 Font Selection Dialog Box Help Choose the Help button to ac...

Страница 40: ...Manager to MOM Controller Board and System Manager to MOM Controller Board serial links enabling disabling data logging and setting the datalog delete threshold number Figure 7 CEC IMC Manager Configu...

Страница 41: ...ud sensing a baud rate change at the MOM Controller Board is not necessary when a change is made in this list box System Manager MOM Baud Rate The MOM Controller Board port used for interfacing with t...

Страница 42: ...og files that are more than 5 days old will be deleted from the hard disk drive at midnight The range for the Datalog Delete Threshold number is 1 to 50 The value selected here should be at least equa...

Страница 43: ...Synchronization Dialog Box Help Choose the Help button to access the Help function Help is also available by pressing the F1 key Current Time and Date The system s current time and date is displayed...

Страница 44: ...me to CEC IMC option must be unselected disabled If the Netclock 2 option is installed select the Netclock option button See WWVB TIME STANDARD CONFIGURATION on page 3 199 for more information on Netc...

Страница 45: ...commended if a System Manager exists If the network s System Manager operates with version 5 0 or later software a console alias cannot be changed at the CEC IMC Manager Therefore CEC IMC Manager cons...

Страница 46: ...on about the transfer currently in progress or the most recent transfer Selected transfer type whether In Progress Complete or Failed and number of Records involved are displayed Request The Request b...

Страница 47: ...utton to broadcast the currently requested database transfer to the CEC IMC interface modules The Current Status box shows the type of transfer selected indicates that the transfer is In Progress and...

Страница 48: ...his is to allow other GUI clients an opportunity to submit requests In the Request box select Full for full upload unlike System Manager transfers which allow partial transfer requests for units and g...

Страница 49: ...d all later Audio Boards utilize eight 8 buses A CEC IMC with 4 bus Audio Boards will not route signals correctly if the CEC IMC is configured for eight buses A CEC IMC with 8 bus Audio Boards but con...

Страница 50: ...dware installed within the CEC IMC for proper and effective routing of audio signals New TDM Bus Configuration The number of TDM Buses the CEC IMC will use to route audio signals is configured from th...

Страница 51: ...ATION This section describes channel related configurations applicable to site type MIM NIM VMIM PIM and CTIM interface modules that are performed at the CEC IMC Manager NIM VMIM PIM and CTIM site typ...

Страница 52: ...matches the site assignment number set by the 5 bit DIP switch setting on the interface module s Controller Board Prior to actual channel configuration the interface module to be configured must be se...

Страница 53: ...p to eight Audio or T1 E1 Interface Boards An optional standby Controller Board may be used with an EDACS trunked site for redundant downlink operation MIM Site Selection Prior to actual channel confi...

Страница 54: ...figuration exists at the CEC IMC Manager and no active Controller Board control data link exists at the CEC IMC for the corresponding site assignment number Any number of these available MIMs may be s...

Страница 55: ...he site and the control data link is active Those site type interface modules followed by TEC are T1 E1 Interface Card equipped and are configured as described in T1 E1 Interface Card Equipped MIM Con...

Страница 56: ...tive Sites list box will be removed and returned to the Configurable Sites list box Audio Interface Type Selection For those site type interface modules that may be equipped with either an Audio Board...

Страница 57: ...he major difference is in the bit rate E1 is a digital transmission facility operating at 2 048 Mbps The difference in bit rate allows for different channel allocation schemes The CEC IMC T1 E1 Interf...

Страница 58: ...d Equipped MIM Channel Configuration This section describes configurations for channels within Audio Board equipped site type interface modules All channel parameters are configured from the Site Chan...

Страница 59: ...box View Current CEC IMC Channel Configuration The lower list box in the Site Channel Configuration dialog box labeled CEC IMC displays the current channel configurations stored at the CEC IMC for the...

Страница 60: ...vels are 10 dBm greater than average voice levels Valid range is 25 0 dBm to 12 0 dBm adjustable in 0 5 dBm increments The program automatically rounds off non 0 5 dBm fractional entries to the neares...

Страница 61: ...nel prior to and during a switch to site transmission The set level is only utilized if Channel Signaling is TONE or BOTH Valid range is 10 dBm to 11 dBm which specifies the secure tone level The 2175...

Страница 62: ...ithout allocating slots to channels 2 and 3 Notch Filter DO NOT enable the 2175 Hz Notch Filter for any channel if the respective Audio Board part number is 19D903302P1 any revision Each Audio Board c...

Страница 63: ...ly selected site type interface module s channel configuration Other sites displayed in the list box located at the top of the dialog box are not saved This channel configuration is saved on the CEC I...

Страница 64: ...lose command and remain in the dialog box Cancel Site Channel Configuration List dialog box Send Choose the Send button to send the site channel configuration data to the respective interface module T...

Страница 65: ...ved sites appearing in the Configured Active Sites list box will be removed and returned to the Configurable Sites list box T1 E1 Interface Card Equipped MIM Configuration This section describes confi...

Страница 66: ...ce all Audio Boards The T1 E1 Interface Card furnishes twenty four full duplex T1 channels in T1 mode and thirty one full duplex E1 channels in E1 mode In addition to its T1 E1 port the T1 E1 Interfac...

Страница 67: ...to SLAVE A with another set to SLAVE B for redundancy or 1 T1 E1 Interface Card set to SLAVE A B for no redundancy 3 Slave to external 1 544 MHz Redundant Clock Circuits generated by the Clock Board s...

Страница 68: ...y If there are any phone company T1 E1 connections one of the connections must be the MASTER source of timing Any other phone company connections may be the redundant MASTER source of timing Phone com...

Страница 69: ...g modem mode the T1 E1 Interface Card transfers PCM encoded signals between the CEC IMC TDM network and the T1 E1 line PCM encoded signals transferred by this mode include analog clear voice modem enc...

Страница 70: ...ice line used Select from the available choices in the drop down list box to match the line format Line Code The line code indicates the method used to encode long strings of zeroes The receiving end...

Страница 71: ...de Selecting the Slave Clock Mode is part of a higher level system design as mentioned earlier Any system nodes that are connected using T1 E1 Interfaces must remain frequency locked at all times The...

Страница 72: ...ecome the new configuration T1 E1 Interface Card Auto configuration Subrate ports and channel assignments are auto configured by the CEC IMC Manager according to the number of free T1 E1 channels In F...

Страница 73: ...Port Auto configuration 0 no subrate ports available 1 port 1 async ports 2 8 not available 2 port 1 async ports 2 5 sync ports 6 8 not available 3 ports 1 2 async ports 3 5 sync ports 6 8 not availab...

Страница 74: ...figuration dialog box Save Choose the Save button to perform an immediate save of the currently selected site type interface module s channel configuration The channel configuration is saved on the CE...

Страница 75: ...n to perform an immediate save of the currently selected site type interface module s channel configuration This channel configuration is saved on the CEC IMC Manager s hard disk drive Any previous ch...

Страница 76: ...ager if different it is sent to the MOM Controller Board if not no further action is taken by the system and when the MOM Controller Board receives this new data it will send an acknowledgment message...

Страница 77: ...ation dialog box as described in DISTRIBUTED MULTISITE STARGATE CONFIGURATION beginning on page 3 141 Those nodes IMC networks that will make up the multinode system must have their Group and Unit Dat...

Страница 78: ...figured and active NIM represents an active operating control link between the NIM Controller Boards in two networked CEC IMC switches Help Choose the Help command button to access the Help function H...

Страница 79: ...r configuration If upon adding a NIM a configuration data file exists on the CEC IMC Manager s hard disk drive from a previous add and delete the NIM will be added to the Configured Active Sites list...

Страница 80: ...t the desired NIMs to configure from the Configured Active Sites list or add the desired NIMs from the Configurable Sites list if not already listed as described earlier Choose Modify and the Audio In...

Страница 81: ...IMC Manager configuration database is lost for any reason A difference between CEC IMC and CEC IMC Manager databases will be evident by comparing the CEC IMC Manager and CEC IMC list boxes in the Site...

Страница 82: ...value from the drop down list box Output Signal Level default 0 dBm Bus Slot Equipped All utilized channels within an interface module must be allocated a time slot on the CEC IMC TDM network Allocate...

Страница 83: ...el configuration is saved on the CEC IMC Manager hard disk drive Any previous channel configuration for the site if present is erased and replaced with the current channel configuration If the CEC IMC...

Страница 84: ...A Send to Site Successful message will be received to confirm that the data was received by the interface module Controller Board Bus Slot configuration data is compared to the current configuration a...

Страница 85: ...de basis Changing the Line Type will cause the complete T1 E1 database to be reset lost The Line Type shown as the default when the Audio Interface Type dialog box appears is how the system is configu...

Страница 86: ...a FREE RUN mode This allows any CEC IMC to become the master source of Network timing All nodes connected to this CEC IMC will be in the slave mode This mode is established by setting the Clock Board...

Страница 87: ...Clock Board DIP switches to Slave to 2048 kHz and all T1 E1 Interface Cards Slave Clock option to NONE The following configuration guidelines must be followed for network synchronization 1 One node in...

Страница 88: ...log clear voice modem encoded digital voice and or modem encoded data signals In this mode each site channel is assigned to a T1 E1 channel In addition this mode allows use of the T1 E1 Interface Card...

Страница 89: ...tted The possible T1 line codes are B8ZS and AMI w ZCS The E1 line code is HDB3 The line code also is determined by the service line utilized Select from the available choices in the drop down list bo...

Страница 90: ...fferent CEC IMC configuration options A detailed discussion of the higher level system configuration is beyond the scope of this topic however for a more detailed discussion refer to T1 E1 Interface R...

Страница 91: ...no user configurable fields in this dialog box the assignment of subrate ports and T1 E1 channels can be viewed on a per card basis in this dialog box Select the card to view from the drop down list b...

Страница 92: ...sk drive Any previous channel configuration for the site if present is erased and replaced with the current channel configuration If the CEC IMC Manager is running remotely or as a part of the EDACS N...

Страница 93: ...nnel configuration If the CEC IMC Manager is running remotely or as a part of the EDACS Network Manager this configuration is saved on the CEC IMC Manager server typically local to the CEC IMC it is n...

Страница 94: ...stem and when the MOM Controller Board receives this new data it will send an acknowledgment message back to the CEC IMC Manager which will then display the confirmation box Do you want to activate TD...

Страница 95: ...nfigurable Sites list box displays all inactive unconfigured site type interface modules If a PIM appears in this box no channel configuration exists at the CEC IMC Manager and no active Controller Bo...

Страница 96: ...dio Interface Type dialog box select either Audio Board or T1 E1 Interface as required by clicking the appropriate option button Selecting Audio Board will activate the Site Channel Configuration dial...

Страница 97: ...ist if not already listed as described earlier Choose Modify to display the Audio Interface Type dialog box select the Audio Board option button then choose OK to display the Site Channel Configuratio...

Страница 98: ...in the Site Channel Configuration dialog box Ensure that the CEC IMC configuration is correct then choose the CEC IMC to Disk button to restore the CEC IMC Manager configuration database for the sele...

Страница 99: ...e 0 dBm 1 milliwatt sent out by the selected channel s line output The setting specifies the voice peak test tone level sent out by the channel The valid range is 25 0 dBm to 13 0 dBm in 0 5 dBm incre...

Страница 100: ...ntrol ALC provides compensation for signal level variances in a channel line input signal As required enable ALC for the selected channel by entering YES in the ALC text box or disable it by entering...

Страница 101: ...n choosing Save As a small dialog box see Figure 17 on page 3 34 will appear which allows selection of a new PIM number Select the desired PIM number from one of the choices in the drop down list box...

Страница 102: ...t to activate TDM Bus Slots OK will cause all CTRL boards to reset Choose OK to activate TDM Bus Slots resetting Controller Boards with the new Bus Slot configuration data choose Cancel to not activat...

Страница 103: ...ilities Consequently co located T1 E1 multiplexing mux equipment at the CEC IMC is eliminated when the T1 E1 Interface Card is employed CEC IMC Audio Boards are also eliminated within the particular i...

Страница 104: ...o the CEC IMC The CEC IMC can be slaved to an external node that is connected through a T1 E1 link and no additional timing source is needed Timing from the T1 E1 line is passed to the Clock Board fro...

Страница 105: ...ork timing The CEC IMC will support a primary and redundant or alternate MASTER sources of timing as indicated above 2 A MASTER node can be defined as a site a Jessica a T1 E1 link or a CEC IMC 3 All...

Страница 106: ...log clear voice modem encoded digital voice and or modem encoded data signals In this mode each site channel is assigned to a T1 E1 channel In addition this mode allows use of the T1 E1 Interface Card...

Страница 107: ...mitted The possible T1 line codes are B8ZS and AMI w ZCS The E1 line code is HDB3 The line code also is determined by the service line utilized Select from the available choices in the drop down list...

Страница 108: ...fferent CEC IMC configuration options A detailed discussion of the higher level system configuration is beyond the scope of this topic however for a more detailed discussion refer to T1 E1 Interface R...

Страница 109: ...no user configurable fields in this dialog box the assignment of subrate ports and T1 E1 channels can be viewed on a per card basis in this dialog box Select the card to view from the drop down list b...

Страница 110: ...e Any previous channel configuration for the site if present is erased and replaced with the current channel configuration If the CEC IMC Manager is running remotely or as a part of the EDACS Network...

Страница 111: ...nnel configuration If the CEC IMC Manager is running remotely or as a part of the EDACS Network Manager this configuration is saved on the CEC IMC Manager server typically local to the CEC IMC it is n...

Страница 112: ...ck to the CEC IMC Manager which will then display the confirmation box Do you want to activate TDM Bus Slots OK will cause all CTRL boards to reset Choose OK to activate TDM Bus Slots resetting Contro...

Страница 113: ...Site Selection Prior to actual channel configuration the interface module to be configured must be selected From the CEC IMC Manager menu bar select Configure System CEC IMC Configuration VMIM When V...

Страница 114: ...d to the Configured Active list box for configuration Configured Active Sites The Configured Active Sites list box displays VMIMs which have been added but not yet channel configured VMIMs which have...

Страница 115: ...lect the Audio Board option button then choose OK The Site Channel Configuration dialog box will be displayed The T1 E1 Interface Card is not supported for the VMIM Delete Choose the Delete button to...

Страница 116: ...per list box in the Site Channel Configuration dialog box labeled CEC IMC Manager displays the current channel configurations stored on the CEC IMC Manager hard disk for the currently selected VMIM As...

Страница 117: ...its configuration data will be displayed in the edit fields above the CEC IMC Manager list box Input Signal Level dBm This setting establishes the signal level in dBm 600 ohm impedance 0 dBm 1 milliwa...

Страница 118: ...re accomplished by the 2175 Hz Hold Tone Level dBm setting in the Tone Controlled Station State Table Mapping dialog box which is a sub box of the Conventional Channel Configuration dialog box Secure...

Страница 119: ...stored on the CEC IMC Manager hard disk To save and send configurations action is required first in the Site Channel Configuration dialog box and then in the Site Channel Configuration List dialog box...

Страница 120: ...nd C A prefixes configurations may be sent All configuration data is sent to the MOM Controller Board the Audio configuration is sent directly out from there to the respective interface module Control...

Страница 121: ...up to 20 channels for CTIS equipment CTIM Site Selection Prior to actual channel configuration the interface module to be configured must be selected From the CEC IMC Manager menu bar select Configure...

Страница 122: ...will also be listed in the Save As dialog box that is accessed from the Site Channel Configuration dialog box If necessary refer to Configured Active Sites Prefix Definitions Table 1 on page 3 25 for...

Страница 123: ...ard Channel Configuration This section describes configurations for channels within Audio Board equipped site type interface modules All channel parameters are configured from the Site Channel Configu...

Страница 124: ...displays the current channel configurations stored at the CEC IMC for the currently selected site type interface module Information within this box updates only after Send is performed from the preced...

Страница 125: ...m adjustable in 0 5 dBm increments The program automatically rounds off non 0 5 dBm fractional entries to the nearest 0 5 dBm Input Signal Level default 0 dBm If Automatic Level Control ALC is disable...

Страница 126: ...ting establishes the level of the 2175 Hz secure tone and transmit hold tone sent out by the Audio Board s channel prior to and during a switch to site transmission The set level is only utilized if C...

Страница 127: ...ny revision Each Audio Board channel is equipped with a 2175 Hz notch filter circuit which when enabled eliminates destructive interference of the channel s 2175 Hz transmit keying tone In some cases...

Страница 128: ...e currently selected CTIM channel configuration Other CTIMs displayed in the list box located at the top of the dialog box are not saved This channel configuration is saved on the CEC IMC Manager s ha...

Страница 129: ...be received to confirm that the data was received by the interface module Controller Board Bus Slot configuration data is compared to the current configuration at the CEC IMC Manager if different it...

Страница 130: ...desirable to disable confirmed call for a SCAT radio system since its single channel could cause unacceptable delays in confirmed wide area group calls Note that if this confirmed call site setting i...

Страница 131: ...from the call confirmation process Select the check box for those sites 1 32 required to participate in the call confirmation process Auto Confirm Call Database Fix In addition removing sites determin...

Страница 132: ...digital confirmed calls processed through Confirm Call Timeout being immediately dropped by Remote Digital Delay The current operation of the Confirmed Group Call feature does not include confirmatio...

Страница 133: ...nect options are available in the System Options dialog box From the CEC IMC Manager menu bar select Configure System Systems Options Telephone Interconnect Do not enable either of these two options u...

Страница 134: ...DACS system that is StarGated has more than one Jessica connected at multiple IMCs This option will cause caller based drops to be sent to the site and when this feature is enabled the caller ID is se...

Страница 135: ...ent number 1 thru 32 within the CEC IMC This number corresponds to and matches the console assignment number set by the 5 bit DIP switch setting on the interface module Controller Board CIM Console Se...

Страница 136: ...Board control data link exists at the CEC IMC for the corresponding console assignment number Any number of these available consoles may be selected at one time to be added to the Configured Active li...

Страница 137: ...ration At least one console must be selected in the Configured Active Consoles list box prior to choosing Modify to display the Console Channel Configuration dialog box Delete Choose the Delete button...

Страница 138: ...26 Console Channel Configuration Dialog Box Help Choose the Help button to access the Help function Help is also available by pressing the F1 key View Current CEC IMC Manager Channel Configuration The...

Страница 139: ...e Channel Selection Select a channel 1 thru 32 for configuration from the CEC IMC Manager channel list box only one channel may be selected at a time The selected channel and its configuration data wi...

Страница 140: ...allocated four 4 slots so CIM channel 4 could be used for Call Director transmit audio In this release only those slots actually required need be allocated therefore a CIM supporting a Call Director r...

Страница 141: ...motely or as part of the EDACS Network Manager this configuration is saved on the CEC IMC Manager server typically local to the CEC IMC it is not saved at the remote location Save As Choose the Save A...

Страница 142: ...Manager which will then display the confirmation box Do you want to activate TDM Bus Slots OK will cause all CTRL boards to reset Choose OK to activate TDM Bus Slots resetting Controller Boards with t...

Страница 143: ...e types include C3 Maestro consoles MAESTRO C3 Modular Desktop consoles MODULAR and C3 Maestro for Windows NT MAESTRO NT If no console exists the Type field will be NONE and the Version field will be...

Страница 144: ...anager 5 0 In systems with a System Manager running V5 0 software the Unit ID LID and Console Alias fields may be edited The Unit ID values entered in these fields must be valid LIDs existing at the S...

Страница 145: ...nto three 3 general groupings Visual Indicators Audio Indicators and Emergency Indicators Supervisor Select this check box if the user on this shift is a supervisor Certain privileges are granted to s...

Страница 146: ...unction Display ID for Alias Select this check box to display IDs GID LID CID etc of incoming calls in the respective console s module title bars Unselect to display labels aliases of incoming calls C...

Страница 147: ...if not the console operator will be given a grant tone when the timer expires signaling the transmission may proceed in a non confirmed state The valid time delay range is 0 10 seconds select desired...

Страница 148: ...the tones at the console Headsets equipped with AGC circuits may defeat this feature Error Tones Select this check box to enable the error tone when the console determines an error has occurred Unsel...

Страница 149: ...m the console s privilege list See Section 3 11 4 a dispatcher cannot make or monitor any Individual Call partial desired units are enabled in the console s privilege list and the Monitor ICALL Privil...

Страница 150: ...le if present is erased and replaced with the current configuration If the CEC IMC Manager is running remotely or as a part of the EDACS Network Manager this configuration is saved on the CEC IMC Mana...

Страница 151: ...ome console parameters are not shift dependent for the C3 Maestro Console these parameters are configured from the C3 Maestro Hardware Configuration dialog box Figure 28 From the CEC IMC Manager menu...

Страница 152: ...se from the CEC IMC Manager hard disk If the console is no longer used or the console never existed the database should be deleted A Message Box will be displayed asking you to confirm OK or cancel Ca...

Страница 153: ...pted Write Changes to Disk to save and exit Yes exit without saving No or cancel the Close command and remain in the dialog box Cancel Digital Console Pre empt Digital console pre empt allows for cons...

Страница 154: ...At this point in the set up process conventional channels cannot be added to the privilege list for a console because they have not yet been defined programmed Conventional channels are programmed in...

Страница 155: ...ted unit will be displayed opposite Unit ID above this list box Press Enter to change the selected unit to the opposite status i e a programmable unit will now be not programmable and vice versa doubl...

Страница 156: ...alog box These actions are performed from the Console Privilege List dialog box Save Choose the Save button to perform an immediate save of the currently selected console s configuration Other console...

Страница 157: ...yes or no Each C3 Modular Desktop console can be equipped with up to sixty four total modules C3 Modular Desktop consoles are configured from the C3 Modular Desktop Console Configuration dialog box Fi...

Страница 158: ...ay be faster and more convenient Module Display Type The Module Display Type may be either ALPHANUMERIC ALPHA or FIXED ALPHA means that the module has an alphanumeric programmable display FIXED means...

Страница 159: ...rrently selected console s configuration Other consoles displayed in the list box located at the top of the dialog box are not saved The console configuration is saved on the CEC IMC Manager s hard di...

Страница 160: ...g No or cancel the Close command and remain in the dialog box Cancel 3 11 6 View Patch Simulselect The View Patch Simulselect option can be used to view deactivate and delete soft patches and simulsel...

Страница 161: ...lselect in the system Described below are the each of the possible states that may appear Requested header received waiting for activate request Req Activate activate request received waiting for firs...

Страница 162: ...patch simulselect has been deactivated This is the preferred method of deactivating a patch simulselect Delete Choose the Delete button to delete a selected patch simulselect Delete sends a deactivat...

Страница 163: ...IUs assigned to this DVIM have been assigned There is no requirement that DVIMs be assigned in sequential order In other words DVIM combinations of DVIM 1 DVIM 3 and DVIM 4 will work the same as DVIM...

Страница 164: ...ite assignment number and the DVIM may be selected for configuration Any number of these available DVIM may be selected at one time Configured Active DVIM The Configured Active DVIM list box displays...

Страница 165: ...oes not remove DVIM channel configuration files from the CEC IMC Manager s hard disk drive If the deleted DVIM is subsequently added back to the Configured Active DVIM list box using the Add button th...

Страница 166: ...a list box at the top center of the dialog box Figure 33 DVIM Channel Configuration Dialog Box Help Choose the Help button to access the Help function Help is also available by pressing the F1 key Vi...

Страница 167: ...Group that was dedicated to the selected channel in the Group Alias field Channel Equipped A Y in this field indicates that the audio channel is connected to a DVIU and can encrypt or decrypt audio E...

Страница 168: ...1 of the DVIM and a group within that agency may be assigned to channel 2 of the DVIM The agency calls will be encrypted decrypted by the DVIU connected to channel 1 of the DVIM and the group calls w...

Страница 169: ...r configurations are required Upon choosing Save As a small dialog box will appear which allows entry of a new DVIM number Do not type a number in the Save As drop down list box the DVIM number must b...

Страница 170: ...on data keeping the previous configuration and return to the DVIM Channel Configuration List dialog box Close Choose the Close button to exit the DVIM Channel Configuration List dialog box and return...

Страница 171: ...ws the user to configure group call console tracking remote CEC interface operation and NIM control data link baud rates for the network These parameters are all set on a per NIM basis The CEC IMC ID...

Страница 172: ...those NIMs with an active site link will be included in this list box When a NIM from this list is selected a notify box Read from disk was successful will appear Read Disk Choose the Read Disk button...

Страница 173: ...NIM on each end of the link must be manually set to equal baud rates via this field Select the required value from the available baud rates of 9600 19 2k and 38 4k Save and Send StarGate Configuratio...

Страница 174: ...NIM STATISTICS screen and observing that the Link State is UP To access the NIM STATISTICS screen select Monitor System from the CEC IMC Manager menu bar then select Statistics from the Monitor System...

Страница 175: ...channel programming Required conventional channel configurations at the CEC IMC Manager include both VMIM related channel configurations and Conventional Interface Adapter CIA rack related channel con...

Страница 176: ...umbers based on the maximum number of conventional channels allowed per CEC IMC and the CEC IMC switch assignment number sometimes referred to as node number node assignment number or device ID Both o...

Страница 177: ...r example conventional channels should not be installed at CEC IMC 33 and CEC IMC 37 if the maximum number of conventional channels per CEC IMC is equal to sixty four 64 Similarly conventional channel...

Страница 178: ...the CEC IMC Manager for CEC IMC 33 or 41 49 57 and channels 225 thru 255 must be programmed at the CEC IMC Manager for CEC IMC 40 or 48 56 64 In this example conventional channels 1 thru 32 are local...

Страница 179: ...tion includes the remote channel s CEC IMC switch assignment number 33 64 its LID number its alias and the range of conventional channels assigned to the remote CEC IMC The switch assignment number an...

Страница 180: ...mmunicates with a conventional channel by its channel number not its LID number A console never uses a conventional channel LID The conventional channel LID is only sent to trunked sites during a conv...

Страница 181: ...ING DEFINITIONS for logged warning information Warnings applicable to StarGate network conventional channels include W20 136 W20 137 and W20 138 Conventional Channel Database CEC IMC Manager Based Sys...

Страница 182: ...rect patching simulselecting of a conventional channel to a trunked talk group A Causeway patch simulselect exists only in the CCI and VMIM Controller Boards The CCI and VMIM use the trunked talk grou...

Страница 183: ...seway patch or a Causeway simulselect after it has been programmed can only be accomplished from the Conventional Channel Configuration dialog box not a console To disable Causeway patch or Causeway s...

Страница 184: ...channels A trunked site originated group call is not routed to the respective Causeway simulselected conventional channel It is only routed to the other trunked radios and consoles monitoring the gro...

Страница 185: ...er voice activation VOX or carrier activation COR Within the CIA rack these functions are provided by CI Board channels Unity gain exists for the audio signals routed through a CI Board channel to fro...

Страница 186: ...ration dialog box Conventional Channel Configuration Dialog Box same as previous UF_CONV EXE must be executed if upgrading CEC IMC Manager software from V3 0 or earlier to V4 0 or later See Software R...

Страница 187: ...CEC IMC and CEC IMC Manager configurations match for the selected channel a save and send or send automatically saves of any changes must be performed As previously mentioned upon entering the Convent...

Страница 188: ...nal channel is possible If a System Manager LID database transfer has not occurred or for some other reason this database is not present at the CEC IMC Manager a default alias exists and is displayed...

Страница 189: ...tion If the currently selected channel is a local conventional channel the following high level channel parameters are displayed for editing purposes If the currently selected channel is a remote conv...

Страница 190: ...elected conventional channel originated calls on the currently selected conventional channel are detected by the CEC IMC calls trip when the channel s line audio exceeds the VOX threshold point specif...

Страница 191: ...s within the CEC IMC In these cases an Audio Concentrator Card is not used The following three 3 mutually exclusive options configure the consoles ability to control relays located on the Conventional...

Страница 192: ...mands for example F6 function key from C3 Maestro console s conventional function note card When the relays are toggled to the standby position assuming recommended wiring for this card configuration...

Страница 193: ...ll but PTT commands E M M lead signaling on PTT commands Standard DC signaling can be modified per State Table low level configurations on a per command basis DC DC E M PTT Standard DC signaling on al...

Страница 194: ...mber must be entered in this text box to specify the group ID number for the Causeway patch simulselect If the EDACS trunked system is equipped with a System Manager the entered number should be a val...

Страница 195: ...ger Configuration data is distributed to the channel s VMIM CIA set as required All settings affect are programmed stored within the CCI Controller Board and the CI Boards within the respective CIA ra...

Страница 196: ...e station remote control signaling requirements The following commands are supported on both tone and DC configurations Table 8 Conventional Base Station Commands COMMAND DEFINITION SET TX FREQ 1 Set...

Страница 197: ...monitor SIM MON DISABLE Disable simultaneous monitor Tone Controlled Station If Tone was selected for Control Signaling in the Conventional Channel Configuration dialog box choosing the State Table b...

Страница 198: ...trol signal that matches the conventional base station configuration for the desired function It will not be possible to program state tables at the CEC IMC without knowing the corresponding base stat...

Страница 199: ...gured Delete Cmd Choose the Delete Cmd button to unconfigure delete a command Save and Send Tone Control Configurations When programming is complete for a channel the new configurations must be sent t...

Страница 200: ...dialog box DC Controlled Station If DC was selected for Control Signaling in the Conventional Channel Configuration dialog box choosing the State Table button will display the DC Controlled Station S...

Страница 201: ...mmands are controlled by applying different current levels on a wire pair to select the required functions Programming the state tables configures the CEC IMC to send the DC control signal that matche...

Страница 202: ...tion levels for proper remote control of the base station For example A conventional base station with two transmit frequencies and two receive frequencies with Channel Guard enable disable capabiliti...

Страница 203: ...ll also be saved to the CEC IMC Manager hard disk when sent to the CEC IMC Save Choose the Save button to save the currently selected local conventional channel s configuration to the CEC IMC Manager...

Страница 204: ...r Configuration dialog box From the CEC IMC Manager menu bar select Configure System CEC IMC Configuration LRIM to display the Logging Recorder Configuration dialog box Figure 38 Figure 38 Logging Rec...

Страница 205: ...d modules more than one module may be selected from the LRIM database 3 15 1 LRIM Module Configuration The Logging Recorder currently supports the programming of units groups and conventional channels...

Страница 206: ...ID System Assigned ID will be routed to each of those groups programmed at the LRIM The Channel text box will automatically display the channel corresponding to the selected module in the Logging Reco...

Страница 207: ...dialog box Choosing OK does not save or send the module programming data Cancel Choose the Cancel button to return to the Logging Recorder Configuration dialog box without making any changes to the s...

Страница 208: ...d module data for the selected LRIM to the CEC IMC MOM This command is analogous to a send all modules command Close Choose the Close button to exit the Logging Recorder Configuration dialog box and r...

Страница 209: ...input and output and interlocking group control is supported However the first release of the console does not support interlocking group control and will not obtain event labels and message informat...

Страница 210: ...able events Select an event to view or configure from this list box An event must be inactive not sent to MOM or deleted before any parameters can be changed To configure a new event select an unused...

Страница 211: ...the Controller Board s processor This may be inverted from the state of the user equipment connected to the Auxiliary I O Concentrator Card due to the wiring of the external connections and the buffe...

Страница 212: ...Console Tone Alarm Use this field to specify if an alarm tone will be heard at the consoles for the event currently being configured Select either Alarm Off or Alarm On from the drop down list box In...

Страница 213: ...lt F8 Aux 4 Console Call Station Busy Station Select Busy Emergency CEC IMC Error Warning occurrence Select the trigger from the drop down list box If any Console Key Press trigger option is selected...

Страница 214: ...ee possible settings are Station Busy Active whenever any transmit or receive audio is present at the console Station Select Busy Active whenever any transmit or receive select audio is present at the...

Страница 215: ...ry I O events are assigned to consoles by selecting the corresponding check box in the Console Mask field upper right quadrant of the dialog box For an output event this specifies which consoles may t...

Страница 216: ...eld is not displayed Read and Delete I O Event Definitions Delete Choose the Delete button to change the selected I O event from enabled to modified not sent The selected event remains on the CEC IMC...

Страница 217: ...event configurations to the CEC IMC Manager hard disk Close Choose the Close button to exit the Auxiliary I O Event Configuration dialog box and return to the CEC IMC Manager main window If any chang...

Страница 218: ...Boards which will activate the TDM Bus Slots Cancel Choose the Cancel button to exit the TDM Bus Slots dialog box and return to the CEC IMC Manager main window without activating TDM Bus Slots 3 20 M...

Страница 219: ...d This allows the operator to retrieve an updated snapshot of unit locations when necessary The multisite unit logout feature controlled by the MOM Controller Board can improve call routing efficiency...

Страница 220: ...ite timer is set to a predetermined time each time it the radio keys Timed logout logs units off of all sites after the requested unit has not shown any activity keyed or login to another site for the...

Страница 221: ...be done regardless of the Logout Timer status A brief description of each follows In order for a call to NOT be routed to a particular group site ALL units must be logged off so that Group Count is eq...

Страница 222: ...Logout dialog box With the timer based multisite unit logout option each unit has a count down timer in the MOM that is initialized at radio login and re initialized at each radio PTT The MOM periodi...

Страница 223: ...other The Unit Alias and LID are linked to the list box directly above these fields the Group Alias and GID are linked to the drop down list box above and right of these fields Save Send Timers Choose...

Страница 224: ...s change in unit location when Send Command Logout is executed 3 20 3 Location Request Three location request options are available unit location unit location by site and group location The location...

Страница 225: ...he location of a unit is defined as the group and site that the unit is currently logged onto When the Unit ALIAS or LID of a particular unit is known but the SITE and or GROUP is unknown this option...

Страница 226: ...s will be displayed in the list box with their Last Known Location Group Alias GID Site Alias and Site ID If All Groups was selected as the Group search parameter the Unit Count for the NO GROUP field...

Страница 227: ...options are discussed in the following paragraphs From the CEC IMC Manager menu bar select Configure System System Options Multisite Settings to display the System Options dialog box Help Choose the...

Страница 228: ...d enabled the multisite unit logout feature operates normally a unit will be logged out from the multisite call routing process when its timer expires If the Multisite Unit Logout check box is unselec...

Страница 229: ...check box unselect the check box to disable this function 3 21 WWVB TIME STANDARD CONFIGURATION A coordinated universal time standard option is available that allows the CEC IMC to be synchronized to...

Страница 230: ...ture is enabled the MOM Controller Board then commands all other Controller Boards in the CEC IMC to switch their Audio Boards to the other clock circuit Redundant Clock Configuration The initial star...

Страница 231: ...failure occurs the MOM will switch all Audio Boards to the A clock and the A clock on Clock Board 2 will become the utilized clock Clock Board 1 can then be removed for service and the B clock on Cloc...

Страница 232: ...clock circuits if the Redundant Clock feature is enabled Errors will be logged at the CEC IMC Manager and audio problems will occur that may or may not be noticeable The audio problems will be more no...

Страница 233: ...a new site based upon the bit error rate of the adjacent sites control channels The roaming operation is referred to as wide area scan or wide area system scan ProSound ensures the newly selected sit...

Страница 234: ...select Configure System System Options ProSound to display the ProSound Site Adjacency Configuration dialog box The ProSound Site Adjacency Configuration dialog box is shown in the following figure Fi...

Страница 235: ...figured for ProSound operation in this field and then press Enter When pressing Enter all other fields on the screen will update in accordance with the current ProSound database configuration saved on...

Страница 236: ...ntly selected site Site ID read write This field defines the site ID numbers of the six possible adjacent sites enter the adjacent site ID number Leave the field set to 0 default if no adjacent site i...

Страница 237: ...nfiguration to exit the ProSound Site Adjacency Configuration dialog box and return to the CEC IMC Manager main window If any changes have been made and not saved you will be prompted Write Changes to...

Страница 238: ...LBI 39224 3 208 This page intentionally blank...

Страница 239: ...cluded within system monitoring are Node Data Feature Data Diagnostics and Statistics Select Monitor System from the CEC IMC Manager menu bar to display the Monitor System menu choices Figure 44 Monit...

Страница 240: ...er Board F0h thru FAh and FCh thru FFh are reserved and cannot be accessed Each installed device in the system is represented by a colored node with the device type displayed on the node The meaning o...

Страница 241: ...ill display current device and board identification data as described in Board Identification below Press the Esc key to exit this screen and return to the CEC IMC Manager main window Hot Buttons Node...

Страница 242: ...re 46 Board Identification Dialog Box Help Choose the Help button to access the Help function Help can also be accessed by pressing the F1 key Close Choose the Close button to exit the Board Identific...

Страница 243: ...d for each individual interface module will be greater than the value displayed in the System Errors field This will occur whenever a global system error currently exists each global system error is c...

Страница 244: ...s to take effect and cannot be changed by the end user For information on upgrading current licenses or obtaining new licenses contact an Ericsson customer support representative A CEC IMC License may...

Страница 245: ...G product in the CEC IMC This license is not required for radio to radio RF Data This feature is enabled if the check box is selected Landline Digital This license allows a customer to perform MultiSi...

Страница 246: ...ork This license specifies the number of NIMs Network interfaces that can be configured in the CEC IMC The value may range from 1 to 8 This license applies to StarGate interfaces and Remote CEC interf...

Страница 247: ...Select Diagnostics from the Monitor System menu to enter the Diagnostics function The first dialog box displayed will be the Active Devices dialog box which lists all active interface modules When a d...

Страница 248: ...ing sections The time range of the report for the selected option is specified in the Range field This time entry must be in the format HH MM SS space XM space MM DD YY twelve hour format AM or PM Any...

Страница 249: ...cted report directly to the connected printer if one is connected A report must be displayed Display button before it can be printed View Errors Current and Logged Figure 48 Diagnostics Dialog Box Err...

Страница 250: ...communications link failure The second numeric value is the type of entity to which the error refers such as the GSC bus or the CEC IMC Manager The short description following the message code reflec...

Страница 251: ...rning message does not reach the CEC IMC Manager it is not re transmitted The GSC address GSCID device type Type and device assignment Assn columns provide the user with an exact location of the warni...

Страница 252: ...and line number where the warning was generated This is used mainly for debugging potential code data flow problems To create a Warnings report select the Warnings option button in the Selection field...

Страница 253: ...about 65 full before writing to the data log file This could mean a delay of up to 5 minutes between keying a call and the call showing up in the data log To create a Call Translation report select th...

Страница 254: ...pter 5 of this manual The buffer at the MOM controller will wait until it is about 65 full before writing to the data log file This could mean a delay of up to 5 minutes between keying a call and the...

Страница 255: ...header since many messages fall into the same format Figure 52 Diagnostics Dialog Box GSC Translation Option Selected GSC Translation should be used when it is desired to view switch site status while...

Страница 256: ...ntitative data related to various devices within the CEC IMC There are currently six types of statistics available for viewing HDLC Channel A HDLC Channel B GSC Node MOM Serial HDLC NIM and TEC T1 E1...

Страница 257: ...address Type Displays the interface module type MIM MOM etc Assign Displays the setting of the interface module s Controller Board dip switches site assignment number Errors Displays the number of err...

Страница 258: ...lues VFR 1 valid frame received CRC 1 CRC check OK RAB 0 received frame not aborted from transmitting station discd A count of received I S or U frames discarded due to the following I frames N R or N...

Страница 259: ...remote stations when no messages have been transferred over the link after a given time interval Rx Queue Overflows A count of received frames lost due to a full receive queue condition HDLC Channel B...

Страница 260: ...ed Displays the time and date of the last Clear Data command GSC ID Displays the current hexadecimal GSC address Type Displays the interface module type MIM MOM etc Assign Displays the setting of the...

Страница 261: ...152 message for 80C186 processing 186 152 Overflows Serial data the 80C186 wishes to transmit out the 80C152 serial port GSC data the 80C186 wishes to transmit onto the 80C152 GSC Interprocessor inter...

Страница 262: ...ton to reset the data display and allow a refresh of the display All counts are from the last reset Close Choose the Close button to exit the NIM STATISTICS dialog box and return to the Active Devices...

Страница 263: ...routed over the NIM interface since the last Clear Data command Call Queued Indicates the number of call attempts queued due to no channel available since the last Clear Data command Call Blocked Ind...

Страница 264: ...ays various information about any T1 E1 Interface Cards that may be installed in the CEC IMC Figure 57 T1 E1 Card Status and Statistics Dialog Box Help Choose the Help button to access the Help functi...

Страница 265: ...nal is being received If the T1 E1 Interface Card detects a T1 E1 signal being received this field will be Y and N if not At the T1 E1 Interface Card LED DS5 labeled SIG will also be illuminated if th...

Страница 266: ...ocking frequency mismatch at the card level causes received frames to be discarded Con MemRes This field indicates the number of Connection Memory Resets accumulated at the CEC IMC since the last Clea...

Страница 267: ...lti frame mode only Indicates the number of Parity Errors accumulated at the CEC IMC since the last Clear Stats command CRC4 Alarm E1 line type operating in CRC multi frame mode only Indicates the num...

Страница 268: ...LBI 39224 4 30 This page intentionally blank...

Страница 269: ...window From the Windows Program Manager window double click on the Main icon then double click on the MS DOS Command Prompt icon At the DOS prompt type c winmom calls exe to execute the CALL EXE utili...

Страница 270: ...riginated CEC IMC originated radio originated and the CALLEE and CALLER involved in the call Valid message groups and sub groups are CHN ASS Channel Assignment GCV Clear Voice CV Group EGCV Emergency...

Страница 271: ...p EGVC Emergency VGCV Group IVC2 ICall II VGCV SGVCI Special Call Group VGCV SGVCI Special Call Group VGCV Inter SIVC Special Call Indiv VGCV SIVCI Special Call Indiv VGCV Inter IVC ICall VGCV AVCMT S...

Страница 272: ...S GCV 80 GRP 273 IND 45 14 36 48 96 1 8 1 1 CHN DRP DROP 80 GRP 273 IND 45 14 36 48 96 1 8 3 1 CHN ASS GCV 80 GRP 273 IND 45 14 36 49 44 1 8 3 1 CHN DRP DROP 80 GRP 273 IND 45 14 36 49 44 1 8 4 1 CHN...

Страница 273: ...0 09 10 01 92 82 50 01 01 00 00 40 09 09 10 01 92 82 1F 04 01 00 00 50 09 09 10 01 92 82 47 05 02 00 00 69 09 09 10 01 92 82 6D 01 09 00 00 40 09 09 10 01 92 82 3B 00 01 00 00 49 09 09 10 01 92 82 57...

Страница 274: ...FB 00 04 00 00 09 09 10 32 16 66 07 00 17 01 01 04 31 03 02 00 3A 06 01 00 09 10 32 64 66 01 01 15 01 01 06 31 03 02 00 1E 06 01 00 09 10 35 04 66 01 01 17 01 01 06 31 03 02 00 1E 06 01 00 09 10 39 84...

Страница 275: ...B receiver which interfaces to the CEC IMC via an RS 232 serial port at the CEC IMC Manager usually COM2 With this option installed the CIMs and consoles are synchronized to the UTC signals broadcast...

Страница 276: ...time and date messages to the CIMs and consoles 6 2 NETCLOCK INSTALLATION The following procedures must be performed in order to implement the NETCLOCK 2 time synchronization option 1 Verify a COM po...

Страница 277: ...fter receiving an ASCII T from the CEC IMC Manager This is the T CMD or SERIAL COM port Refer to the section of the NETCLOCK 2 instruction manual concerning NETCLOCK 2 data formats for additional deta...

Страница 278: ...25 FEMALE 2 3 7 MANAGER CEC IMC TO NETCLOCK 2 TO SERIAL COMM COMM PORT PORT 25 Pin CEC IMC Manager COM Port Figure 59 NETCLOCK 2 T CMD Interconnections 1 sec REMOTE OUTPUT Interconnections The 1 sec...

Страница 279: ...Figure 60 NETCLOCK 2 Remote Output Connections 6 2 2 Software Installation Notes The NETCLOCK 2 interface is integrated into the Microsoft Windows NT operating system The Timeserv exe must be configur...

Страница 280: ...red ANTENNA LED indicates there has been a loss of antenna continuity A red SIGNAL LED means the received signal is weak and carrier lock has been lost This LED can be expected to flash red occasiona...

Страница 281: ...stem with firmware prior to version 2 00 or with a firmware version more recent than the CEC IMC Manager software version Corrective Action Ensure all Controller Boards in system are equipped with fir...

Страница 282: ...ing the error Observe the clock LEDs on the Audio Boards at the interface module generating the error If they are all lit the problem is likely in the clock failure detection circuit If any of the LED...

Страница 283: ...ch bit set When this error occurs all devices in the CEC IMC are commanded to switch to the alternate GSC bus If an end node responds on the new GSC bus the error will be cleared If not a switch is ma...

Страница 284: ...35 LINK FAIL HDLC CHANNEL A No information is contained in the data word The idle flag sequence cannot be detected on HDLC channel A Corrective Action To clear the error proper connection to HDLC chan...

Страница 285: ...ve this error active Change the device type assignment setting of the board in error All boards that conflicted must be reset to clear the error E07 119 INVALID REDUNDANCY MULTIPLE END NODES Lower byt...

Страница 286: ...g must be changed to not conflict with another device The other device should also be displaying this error and it should also be reset E09 139 T1 E1 INTERFACE LOSS OF SIGNAL Data field is the T1 E1 I...

Страница 287: ...IMC Software will require licenses to specify the operational features and maximum capacities for a CEC IMC Node The licenses must be installed at the CEC IMC Manager PC for the desired feature capac...

Страница 288: ...IMS Causeway Max number of Causeway Patch Simulselects SiteChan Max number of site channels NetChan Max number of Network NIM channels Normal data field contains no data always 0 The feature license h...

Страница 289: ...contains a software version greater than or equal to the most recent Controller Board firmware being used W01 048 UNDEFINED CALLEE TYPE The callee type value that generated the warning Unknown callee...

Страница 290: ...of entry count when the attempt was made to add another entry An attempt was made to add another entry create a patch simulselect but the MOM Controller Board patch simulselect table already contains...

Страница 291: ...OLE TRANSMIT REQUEST Message group value that generated the warning Unsupported message group from a CIM or site type interface module MIM NIM VMIM CTIM PIM etc W04 083 UNSUPPORTED GRP SLOT ASSGN Mess...

Страница 292: ...d node This message is not generated by MOM Controller Board firmware version 3 00 or later it is replaced by error message E07 119 WO6 134 MISMATCH BACKUP ID New backup node ID MOM has received a new...

Страница 293: ...units attempted to transmit to the same callee at the same time The CEC IMC will only allow one active transmitter on a talk group The rejected call will be routed to all dispatch consoles but will n...

Страница 294: ...not decrypt the radio to landline call CTIM Sec Ack warning and the caller and callee of the failed confirmed call A secondary acknowledgment was not received from the PIM CTIM for the radio originat...

Страница 295: ...M for the landline originated encrypted Jessica CTIS call Site Queued warning and the caller and callee of the failed confirmed call The landline originated encrypted Jessica CTIS call was queued at t...

Страница 296: ...olls from the Controller Board This warning could indicate the high speed serial link HDLC Protocol between the Controller Board and one of its Audio Boards is not functioning This warning will also b...

Страница 297: ...rbitration on a StarGate network each CEC IMC must have a unique switch ID W16 129 VALUE IN USE SAID VALUE The SAID value An attempt was made to create a patch simulselect with a SAID System Assigned...

Страница 298: ...ile RAM NOVRAM cleared on Controller Board due to a change in device assignment DIP switches This only occurs on certain device personalities W18 132 NOVRAM CLEAR NEW DEVICE TYPE Previous type value i...

Страница 299: ...been defined on a remote CEC IMC Manager and the definition has been received by this CEC IMC Manager This warning is for information purposes only It is generated as part of normal operation to prov...

Страница 300: ...r of NIMs Em CEC Minimum Number of Remote CEC NIMS Causeway Max number of Causeway Patch Simulselects SiteChan Max number of site channels NetChan Max number of Network NIM channels Data field contain...

Страница 301: ...Windows NT V5 0 setup but as a separate installation diskette Open an MS DOS window From the Windows Program Manager window double click on Main icon then double click on MS DOS Command Prompt icon At...

Страница 302: ...on the EDACS entry so that it is highlighted Select Edit from the menu bar and Add Key from the drop down menu For Key Name enter CurrentVersion and leave the Class field blank Choose OK Click on the...

Страница 303: ...l boxes Site Channel Configuration dialog box Text in scroll boxes Console Privilege List dialog box Text in scroll boxes Diagnostics dialog box Text in scroll boxes Unit Group Location and Unit Logou...

Страница 304: ...LBI 39224 D 2 This page intentionally blank...

Страница 305: ...actual name of the machine computer running the CEC IMC Manager server or a TCP IP address of the form XXX XXX XXX XXX The CEC IMC Manager server GUI_SERVER exe is not available and has caused the cli...

Страница 306: ...hat an error probably occurred in the installation of the CEC IMC Manager program One or more required files could not be located when attempting to execute the client program A message listing the mi...

Страница 307: ...from using the entered ID If the console selected does not exist in the CEC IMC in this example Console 7 this message will be displayed when a Send of Console User Profile or C3 Maestro Hardware con...

Страница 308: ...ll T1 E1 interface modules T1 or E1 selection is dependent upon the line service coming into the CEC IMC T1 and E1 lines are physically different Selecting T1 or E1 should only be required when the sy...

Страница 309: ...attempted When Bus Slot configuration data is sent from the CEC IMC Manager to the CEC IMC the Bus Slot data is first compared to the current configuration at the CEC IMC Manager if different this da...

Страница 310: ...ayed refers to the CEC IMC switch assignment number If any active devices haven t been configured for audio when the CEC IMC MOM Controller Board CEC IMC Manager communication link is established this...

Страница 311: ...ent to the appropriate interface module Controller Board Any Bus Slot configuration data will be compared to the current configuration at the CEC IMC Manager if different this data is sent to the MOM...

Страница 312: ...LBI 39224 E 8 This page intentionally blank...

Страница 313: ...utes audio mobile data and Aegis data between EDACS radio systems dispatch consoles logging recorders etc The board digitizes analog signals applied to its audio inputs and applies the digitized signa...

Страница 314: ...tched directly to a trunked talk group via the trunked group s Group ID GID number All conventional channels in a CEC IMC can be Causeway patched Causeway patches are setup and deactivated at the CEC...

Страница 315: ...s and voting systems to be connected to the CEC IMC It is considered a secondary interface since it does not have direct TDM and GSC bus connections to the primary CEC IMC interface modules CIM Consol...

Страница 316: ...y fields within the program The default values assume that the program will be used without optional features Before changing default values the operational implications should be understood distribut...

Страница 317: ...tisite communication can occur Failsoft Failsoft refers to an EDACS trunked site s mode of operation when the site s Site Controller is not operational The site s control channel GETC has primary cont...

Страница 318: ...l are much different from those used in representing data HSCX Highlevel Serial Communications Controller eXtended The HSCX is an integrated circuit IC designed to implement high speed communications...

Страница 319: ...mission trunked call MIM MASTR II III Interface Module The MIM connects an EDACS radio system to the CEC IMC switch EDACS radio systems include EDACS sites simulcast systems CNI systems and SCAT syste...

Страница 320: ...uration and diagnostic procedures NOVRAM reset See NOVRAM clear patch The term patch refers to the operation performed when two or more entities are connected together for common communication as one...

Страница 321: ...itted by the radio operator to identify the current condition in route at scene etc of the unit secondary interface The term secondary interface refers to the CIA rack This rack is considered to be se...

Страница 322: ...MC Manager and StarGate Controller TDM bus Time Division Multiplexed bus The TDM bus in the CEC IMC Digital Audio Switch is a digitally multiplexed bus system used to transfer audio mobile data and Ae...

Страница 323: ...nventional satellite receiver voting systems to be connected to the CEC IMC XLTR C3 Modular Desktop Console Translator Using data protocol conversion techniques this interface module allows the CEC IM...

Страница 324: ...LBI 39224 G 12 This page intentionally blank...

Страница 325: ...sk 3 185 error warning trigger 3 184 I O event configuration 3 180 input event 3 182 log event state changes 3 185 output event 3 183 read and delete I O event 3 186 save and send I O event 3 186 B ba...

Страница 326: ...CAM 3 179 Channel Equipped 3 52 3 137 Channel Signaling 3 31 3 69 3 88 CIM audio board configuration 3 108 3 110 CIM selection 3 105 save and send audio board configuration 3 110 client remote 2 3 si...

Страница 327: ...3 91 save and send audio board configuration 3 98 D data logging enable disable 3 11 exiting program 3 208 dc control conventional channel configuration 3 166 3 170 Diagnostics Hot Buttons 4 3 Digital...

Страница 328: ...T1 E1 configuration 3 62 T1 E1 configuration 3 55 Notch Filter 3 32 3 70 3 88 NOVRAM clear reset 3 19 3 203 O Output Signal Level 3 30 P password change 3 8 create 3 5 3 7 default 3 2 3 3 patch soft...

Страница 329: ...7 3 8 system clock 3 12 System Manager baud rate selection MOM link 3 11 CEC IMC time source 3 14 Confirmed Call considerations 3 100 console user profile considerations 3 114 conventional channel con...

Страница 330: ...ration 3 86 save and send audio board configuration 3 89 VMIM selection 3 83 W W_GUI exe 1 1 2 3 WINMOM 1 1 C 2 X XLTR 3 127 Ericsson Inc Private Radio Systems Mountain View Road Lynchburg Virginia 24...

Отзывы: