LBI-39224
A-1
7. APPENDIXES
7.1 APPENDIX A - LOGGED ERROR DEFINITIONS
LOGGED
ERROR
MESSAGE
LOGGED
ERROR
DATA
CAUSE/
CORRECTIVE
ACTION
E00-xxx:
UNKNOWN ERROR
An error has been generated within
the CEC/IMC, but the CEC/IMC
Manager cannot determine what it
is. This is usually a result of a
Controller Board residing in the
system with firmware prior to
version 2.00 or with a firmware
version more recent than the
CEC/IMC Manager software
version. Corrective Action:
Ensure all Controller Boards in
system are equipped with firmware
version 2.00 or greater and the
CEC/IMC Manager contains a
software version greater than or
equal to the most recent Controller
Board firmware being used.
E01-019:
HW FAIL - AUDIO
BOARD
Data field is the
Board affected.
Audio board type does not match
configuration data, i.e. analog
board, but configured for digital.