LBI-39224
6-4
OUT
IN
GND
2
3
5
RXD
TXD
GND
(DB-9 MALE)
(DB-9 FEMALE)
2
3
5
MANAGER
CEC/IMC
TO
NETCLOCK/2
TO
SERIAL COMM
COMM PORT
PORT
9-Pin CEC/IMC Manager COM Port
OUT
IN
GND
2
3
5
RXD
TXD
GND
(DB-9 MALE)
(DB-25 FEMALE)
2
3
7
MANAGER
CEC/IMC
TO
NETCLOCK/2
TO
SERIAL COMM
COMM PORT
PORT
25-Pin CEC/IMC Manager COM Port
Figure 59 NETCLOCK/2 T-CMD Interconnections
1/sec (REMOTE OUTPUT) Interconnections
The 1/sec (REMOTE OUTPUT) requires a 9-pin male connector at the
NETCLOCK/2. The CEC/IMC Manager end will be either 9-pin
female or 25-pin female, depending on the specific configuration of the
PC. (See Figure 60 below.)