LBI-39224
3-193
listed in 15-minute increments from 15 minutes to 24 hours, including
No Timeout.
Manual Entry
For timer based unit logout manual entries also can be made. These
allow the operator to immediately jump to a unit or group that has a
known ID or ALIAS by typing the ID or ALIAS in the appropriate
Manual Entry text box instead of scrolling through the list of Aliases.
The time-out value also can be manually entered in the Select Timeout
field (text box portion of the Select Timeout drop-down list box), the
drop-down list will go to the typed-in value; however, the value must be
selected with the selection cursor to be recognized as the new time-out
value. Enter either the Alias or ID and press the Tab key.
The Group and Unit information displayed in their respective
fields are not related to each other. The Unit Alias and LID
are linked to the list box directly above these fields; the Group
Alias and GID are linked to the drop-down list box above and
right of these fields.
Save/Send Timers
Choose the
Save/Send Timers
button to save and send the timers
when all the timers are set to the desired values. The transmission of
the timers to the MOM Controller Board occurs at a rate of 3/second.
The transmission status of the timer database is indicated by either YES
(transmitting data) or NO (not or completed transmitting data),
displayed below "Busy Transmitting Timers."
Set All Timers to Same
Choose the
Set All Timers to Same
button if it is necessary to set
ALL timers to the same value after setting one timer to the desired
value. Choosing
Set All Timers to Same
will cause ALL timers to
be set to this new default timer setting and will transmit the new timers
to the MOM Controller Board. The new timer setting becomes the
default setting so any new units added to the database will have this
default.
NOTE
Содержание LBI-39224
Страница 1: ...LBI 39224 ericssonz Operations Guide EDACS CEC IMC MANAGER Version 5 0 for Windows NT...
Страница 2: ......
Страница 6: ...LBI 39224 vi This page intentionally blank...
Страница 16: ...LBI 39224 xvi This page intentionally blank...
Страница 22: ...LBI 39224 1 6 This page intentionally blank...
Страница 30: ...LBI 39224 2 8 This page intentionally blank...
Страница 238: ...LBI 39224 3 208 This page intentionally blank...
Страница 268: ...LBI 39224 4 30 This page intentionally blank...
Страница 304: ...LBI 39224 D 2 This page intentionally blank...
Страница 312: ...LBI 39224 E 8 This page intentionally blank...
Страница 324: ...LBI 39224 G 12 This page intentionally blank...