background image

 

 

 
 

 

 

Operating instruction 

Hydraulic system with Motor drive PXD compact

 

 

 

Document no.: B-00021 

Edition 2019 09

 

Operating instruction EN 

Copyright by Ergoswiss AG

 

4/25 

 

1

 

System description 

1.1

 

General 

The basic functionality of a hydraulic lifting system by Ergoswiss AG (

motor drive 

 pump 

 tubing 

 

cylinder

) is the lifting, lowering and tilting of work surfaces, machine parts, profile systems etc. 

 
All Ergoswiss hydraulic lifting systems with the pump types PA, PB and PF (with woodruff key) can be driven 

by the motor drive PXD compact. The motor drive PXD compact consists of a motor PXD, a control box com-

pact-3-eco, a manual control switch Memory, different connection cables and a plastic housing. 
 
The intelligent control box compact-3-eco is equipped with a highly efficient switched-mode power supply 
(SMPS) and a monitoring software (overload, duty cycle, overheat). Due to the optimised driving comfort, 
the end positions are gently approached as low-speed zones up to the standstill. Additional functions, such 

as the synchronisation of two to four drives or the connection of safety strips (squeezing protection) can be 

used. 
 
With the manual control switch Memory the hydraulic system can be operated comfortably, the work surface 
will be adjusted steplessly in its height. The current height of the work surface is continuously shown on the 

display (cm or inches). Up to four different memory positions can be stored and approached individually.  
 

1.2

 

Intended purpose use 

The motor drive PXD compact is exclusively intended to control and drive Ergoswiss AG hydraulic lifting sys-

tems. While mounting the lifting system into a greater system and while operating the system, the specified 
normal operation of the entire system is to be complied with. Commissioning is prohibited until the entire 

system complies with the provisions of EG Machinery Directives 2006/42/EG (Machinery Directive). 
The system is only to be installed and used indoors in dry conditions.  
The operating temperature range is at 0° C to +40° C. 
The motor drive PXD compact must not be overloaded. Do not exceed the given maximum lifting loads of 

the hydraulic lifting systems. 
The lifting system can be continuously operated for a maximum of 2 minutes. Afterwards a pause of at least 
18 minutes needs to be observed before the system can be operated again. To avoid overheating of the sys-

tem a duty cycle of 2/18 (ON/OFF) should be maintained in general. 
 

1.3

 

Target group and prior knowledge 

This operating instruction addresses the following groups of people: 
 
The 

commissioning staff

, who install and commission the motor drive PXD compact and the Ergoswiss AG 

hydraulic system as an incomplete assembly into a work station, a machine, ect. For commissioning activi-

ties, mechanical and electrical knowledge is prerequisite. Before using the system for the first time the oper-

ating instruction must be read. 
 
The 

end user

 controls the complete system via manual control switch and adjusts its height. 

Before using the system for the first time the operating instruction must be read and understood. 
 

 

Содержание 112.00081

Страница 1: ...able PXD Motor PXD with front plate and housing PXD Cable strain relief PXD coupling for connection to the Ergoswiss hydraulic pumps type PA PB and PF with Woodruff key Errors and technical changes re...

Страница 2: ...drive PAD 230 compact EU 112 00081 230 compact CH 112 00083 230 compact UK 112 00085 110 compact US 112 00087 230 compact IT 112 00089 Motor drive PBD 230 compact EU 112 00082 230 compact CH 112 0008...

Страница 3: ...itch Memory 15 4 2 Initial operation with manual control switch Up Down 15 5 Operation 16 5 1 Drive Up Down 16 5 2 Duty cycle monitoring 16 5 3 Saving a memory position Only with manual control switch...

Страница 4: ...ividually 1 2 Intended purpose use The motor drive PXD compact is exclusively intended to control and drive Ergoswiss AG hydraulic lifting sys tems While mounting the lifting system into a greater sys...

Страница 5: ...2 Control box PXD compact 3 eco Supply voltage EU 207 254 4 V 50 Hz US 90 127 V 50 60 Hz Primary standby power 0 6 W Performance rate 83 300 W input power Hall sensor supply voltage 5 VDC 10 250 mA A...

Страница 6: ...immediate threatening danger Non compliance with this information can result in death or serious personal injuries invalid ity WARNING Indicates a possible dangerous situation Non compliance with this...

Страница 7: ...d in a potentially explosive atmosphere The control box must be protected from moisture dripping water as well as spray water The control box is not suitable for continuous use The operation hold rati...

Страница 8: ...sible residual dangers for example by constructive measures or by instructions in the operating instructions and or by safety instructions on the system 3 1 Mounting and wiring of the motor 1 Connect...

Страница 9: ...he cylinder of the motor 3 2 Mounting and wiring of the control box Mounting of the control box underneath a table top ATTENTION During mounting of the control box the power cable must be disconnected...

Страница 10: ...made products to the control box is prohibited Only use supplied components 1 Connect the motor cable to the control box The continuous cable must be plugged into the motor socket M1 the split cable m...

Страница 11: ...nnected to the correct sockets M1 M2 Is the entire lifting system assembled according to the assembly instructions NOTE The motor cable connecting the control box to the motor has a length of 950 mm I...

Страница 12: ...control panel must overhang below the work surface 2 Fasten the mounting plate using the mounting screws Be careful not to drill through the table top 3 Slide the manual control switch onto the mounti...

Страница 13: ...eath the table top The control panel must overhang below the work surface 2 Fasten the manual control switch using the mounting screws Be careful not to drill through the table top 3 3 4 Manual contro...

Страница 14: ...an gers for example by constructive measures or by instructions in the operating instructions and or by safety instructions on the system ATTENTION While using the height adjustment of the work surfac...

Страница 15: ...display in cm US 110 V version in inch 6 To confirm press S Save After confirmation the height is displayed no more flashing and the initial operation is completed NOTE The control box automatically o...

Страница 16: ...an be operated again 5 3 Saving a memory position Only with manual control switch type Memory With this function it is possible to memorise a certain position height and approach it at a later time by...

Страница 17: ...While doing so the system does not move 4 With the correctly set value the new height is saved by pressing S Save 5 6 Reset of the control box Only with manual control switch type Memory 5 6 1 Redefin...

Страница 18: ...an be connected and synchronised The length of the SYNC 2 cable is 550 mm The SYNC cable cannot be extended If necessary the motor cables can be extended NOTE Always do reset before disconnecting Disc...

Страница 19: ...SYNC cables are connected afterwards they will not be recognised by the control box and only one drive will move which can lead to jamming of the entire system NOTE When disconnecting the SYNC cable...

Страница 20: ...rn Depending on the combination of systems hydraulic transmission ratio the system stops its movement 3mm 5mm or 10 5mm before the defined end position The safety strip compact 124 00105 consists of 7...

Страница 21: ...strip both can also be connected with the split cable Gluing the contact tube in the squeeze zone Connecting the safety strip 1 Clean and degrease the contact face 2 Pull off a liner of acrylic foam o...

Страница 22: ...ly original replacement parts may be used For all repair work the system must always be unloaded and voltage free ATTENTION In no case may the control box be opened There is the risk of an electrical...

Страница 23: ...nt motor group 1 49 Excess current motor group 2 60 Collision protection 62 Excess current at the control 36 Plug detection at motor socket M1 Plug in the motor cable correctly at the respective socke...

Страница 24: ...ed There is an error code to be checked on the display 3x 6x Last shut down incomplete forced reset There is an error code to be checked on the display 8 7 Trouble shooting Error Cause Rectification D...

Страница 25: ...Operating instruction Hydraulic system with Motor drive PXD compact Document no B 00021 Edition 2019 09 Operating instruction EN Copyright by Ergoswiss AG 25 25 9 Declaration of Incorporation...