![Ercogener GenLoc 54e Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/ercogener/genloc-54e/genloc-54e_user-manual_2421804074.webp)
EG_GenLoc54e_1040_UG_002_UK
Page 74 / 86
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCOGENER reserves the right to make any modifications.
Dct_427_02
8.2.4.4
Analog inputs
Table 59 : Characteristics of analog inputs
Characteristics
Symbols
Conditions
Min.
Typ.
Max.
Unit
Analog input
ANA1 / 2
-0.3
128
V
DC
Conversion range
1.3 µ
10.33
V
DC
Polarization current
From 1.3 µV to 10.33 V
0.064
345
µA
DC
Resolution
10
bits
The integrator has the responsibility to protect the input from electrical perturbations and to
respect the functioning parameters values.
Figure 37 : Internal electrical scheme of analog input
8.2.5
SIM interface
Table 60 : Characteristics of SIM card supply voltage
Carte SIM
3 V ou 1.8 V
Format
Standard (mini SIM
– 2FF)
8.2.6
Option 2
nd
SIM interface
Contact us.